Hi Tanmay. Please keep making videos on different topics.
@pritamdas70112 күн бұрын
Thanks a lot 👍🏻
@jyotipatil47805 күн бұрын
nice information, please make a video on Slotted connections
@gnidnoeled7866 күн бұрын
Sir, this question is just to confirm if I did understand your lecture about footing with uplift. For column at the edge of the footing (= with uplift) : L = 3.5 m , B = 2.5 m. Column dim is 0.60 x 0.45 m. Pu = 1800 kN, located 1.45 m from footing center line, column Mu = 444 kN-m. The resulting moment at the centroid of the footing is 2166 kN-m. Thus, e = 2166 /1800 = 1.203 m. c = L/2 - e = 3.5/2 - 1.203 m = 0.547 m. My question : is actual q = 2P / (3c X B) = 2 X 1800 / ( 3 x 0.547 x 2.5 ) = 877.51 ? Thanks in advance for the reply.
@oluochphelix314210 күн бұрын
Such a good approach to teaching concepts.
@smithaks670511 күн бұрын
Respected Sir, You should permit a One time payment of fixed amount / subscription option for those who want the same, say courtesy charges
@kevintong518116 күн бұрын
Your theta is incorrect. Cut the chalk where To is and look at its cross section which is a circle. A radius of the circle turns by theta under To. This is the same theta whether you are looking towards A or B which gives thetaA = thetaB.
@brianng374816 күн бұрын
Great video, however do you also need stiffeners inside the SHS profile? For example a huge SHS-1000x50, won't the inside work the same as a bending plate?
@jalalmiah28018 күн бұрын
Very helpful video ❤
@jalalmiah28020 күн бұрын
Nice lecture
@llingdendavid330923 күн бұрын
❤❤❤❤❤ stay safe and strong 💪🙏.
@Xionarq25 күн бұрын
what if we only have 4 bays?
@sribalambika476528 күн бұрын
Sir I learned a lot from your videos.Are you conducting any online structural design courses sir ? and can you please share your contact details?
@akshayambekar811829 күн бұрын
hi tonmoy Sir, i just working on process building and converter plant where vender give bundle load for heat exchanger..so my question is how to apply this bundle load on STAAD??
@John-fk7tkАй бұрын
Well explained 👍
@TonmoyMaityАй бұрын
Thanks, glad you liked it!
@GeetaLingarkarАй бұрын
Sir make video on vertical vessel please
@TonmoyMaityАй бұрын
I can definitely add that to my list!
@GeetaLingarkarАй бұрын
Sir nice explanation 👍
@GeetaLingarkarАй бұрын
Sir your explanation way is very clear to understand concept....thanku sir
@kunalbadgujar8628Ай бұрын
Great
@Haami-1Ай бұрын
thanks a lot brother
@lokhandesuyesha905Ай бұрын
Very nicely explained
@divyapatil6569Ай бұрын
Hoy hoy
@joey_joe8557Ай бұрын
Thank you 👍
@nalin8050Ай бұрын
Thank you. Good clarity
@allinone-tb9ne2 ай бұрын
Wrong absorption - moisture hota hai
@ElvanDaltonnn2 ай бұрын
%99 okay %1 web is buckling (just kidding)
@MattRidzonPE2 ай бұрын
I think I'm misunderstanding. At 02:15 - 02:20, you point out the lower left joint that has non-zero rotation. That joint looks fixed though. Can you explain how that joint has non-zero rotation?
@julianafeijo92212 ай бұрын
Amazing, thank you!
@jyotirupsarkar92382 ай бұрын
Quite useful video but I have modelled chevron bracing in Staad applying a lateral load of 5 Kn.Here it is showing tension and compression in two bracing
@user-NOBLESSE2 ай бұрын
Thank you sir. ( ˘ ³˘)♥
@7anashMalaysia2 ай бұрын
wrong
@AqsaNeaz2 ай бұрын
Amazing
@swapniljagtap70652 ай бұрын
Hi sir. Thank you for making such good and easy understanding videos. Sir can you please make a video on " How to calculate loss of contact in footings?"
@satyawanmore80142 ай бұрын
Sir if we have headroom issue for providing entrance bracing, is there any other option for this type of situation
@cloudythoughts7682 ай бұрын
Usually in offshore, the I beam will be welded to the base plate (no bolted connections used). Then it means the column is fixed right?
@abdullahiahmedmohamed39252 ай бұрын
You really naild my subscription brother you're amazing
@zaid3672 ай бұрын
can you post a link for this word file please?
@vikassaraf-z4x2 ай бұрын
where to apply pinned or fixed load in PEB structure?? say single span or multi span?
@hnm10212 ай бұрын
Thank you very much for your effective explanation. Can you send me the building photos used at 6 mins and onward? thank you.
@RabibSekh2 ай бұрын
Hi sar
@mdatiqurrahman98553 ай бұрын
Please explain why main reinforcement place in long direction first of flat plate slab
@subhaghosh-mh9nk3 ай бұрын
If mistakenly distribution bar provide in bottom most and main bar fixed in top of the distribution bar then what will happened kindly explain
@BINAYAKSAMANTA3 ай бұрын
Sir please carry on❤
@BINAYAKSAMANTA3 ай бұрын
Is membership videos still available?
@sports-oh1gp3 ай бұрын
Sir your explanation is very very good Sir i need to take full course if anything available regarding this
@BlueDogTabby3 ай бұрын
Thank you
@TonmoyMaity3 ай бұрын
You're welcome
@mohab963 ай бұрын
But wouldn’t both sides of the bridge be a roller support or act as a roller support ? I hope you can answer this one . Thanks!