TC78ex-NI Unboxing | EN | BARTEC
2:00
Пікірлер
@АлександрТитов-с2х1о
@АлександрТитов-с2х1о 2 ай бұрын
Hi! We have a problem with bartec apex. He didn't switch on. Can someone help? Сan't deliver for manufacturers.
@jslygld0301
@jslygld0301 3 ай бұрын
OMG, i love her voice so much
@recithree
@recithree 5 ай бұрын
How about verifying that the other end of wire doesn't have conductors touching.
@MarkoKastellon
@MarkoKastellon 6 ай бұрын
Women test 😊
@norman20100
@norman20100 6 ай бұрын
woman electrician xd
@MasterTheNEC
@MasterTheNEC 7 ай бұрын
Why not explain WHY the meg wont work if their is no BRAID......Go ahead, I'll Wait.
@bobpierson7107
@bobpierson7107 8 ай бұрын
Great product and company.
@ehsanazadi-gw7qo
@ehsanazadi-gw7qo 8 ай бұрын
Hello I am an analyzer expert and a user of one of your analyzers to the specifications of the Rapid Distillation Process Analyzer I am working on rapiDist-4. This device has an alarm Alarm: chiller alarm (kWS alarm) Please help me to fix this alarm.
@BARTECglobal
@BARTECglobal 8 ай бұрын
Hello @ehsanazadi-gw7qo! Thank you for reaching out with your comment. We appreciate your interest. For more detailed assistance, please don't hesitate to drop us an email at [email protected]. Our team will be more than happy to provide you with the information you need.
@FourbeEnfantInes
@FourbeEnfantInes 8 ай бұрын
Great products!
@ibnuabassmohammed8474
@ibnuabassmohammed8474 9 ай бұрын
Please you are too fast We are learning from it Next video slowly and let's see the values recorded too
@JilanKhadri-vn4ln
@JilanKhadri-vn4ln 10 ай бұрын
Waste of time.
@asifahmed7080
@asifahmed7080 Жыл бұрын
where is she now? not seeing any vids lately
@___Q-bot
@___Q-bot Жыл бұрын
does anyone know what is the kind of the reel of red cable? is it for electricity or signals?
@barrelsage3784
@barrelsage3784 3 ай бұрын
Heat trace I believe
@BNDofDoom
@BNDofDoom Жыл бұрын
Lol wince in 2021
@acefuellas2137
@acefuellas2137 Жыл бұрын
why 550 meg is always the reading of a good insulation
@chchandrasekhar3912
@chchandrasekhar3912 Жыл бұрын
What is the test voltage
@tfun101
@tfun101 Жыл бұрын
I’m sorry I don’t agree…we had 2 raychem techs come out to our site and Megger all of our heat trace. I worked with them for 3 days megging countless heat trace. I was told the minimum is 1 Giga Ohm of resistance “phase” to ground. They said specifically anything below 60 Mohms requires a level 2 diagnostic which is going out into the field and opening boxes to look for the problem. 20 ohms to them is a huge problem. With all do respect..what the f*ck are you talking about.
@joshuaboehler
@joshuaboehler Жыл бұрын
She said 20mega Ohm's not 20 ohm's. 20 ohm's is basically a dead short.
@tfun101
@tfun101 Жыл бұрын
@@joshuaboehler20 mohms, 20 ohms it doesn’t matter my guy. Read what I said.
@champ8605
@champ8605 10 ай бұрын
Depends on the voltage used for testing. They most likely tested upwards of 5kv whilst this test was under 500v. You're clearly not an electrician and dont know what you're talking about.
@tfun101
@tfun101 10 ай бұрын
@@champ8605 Most likely tested upwards of 5kv? 🤣. You’re sooo clueless bro..
@garza1367
@garza1367 10 ай бұрын
You were also told, face mask and vaccines would help stop/spread covid from “qualified” people… moral of the story, not every “professional” gives the right info
@marcodayao4127
@marcodayao4127 Жыл бұрын
How much would this cost?
@BARTECglobal
@BARTECglobal Жыл бұрын
Hi Marco! Thanks for your comment. Email us at [email protected] and we will be happy to assist you!
@JuanMartinez-mf5bm
@JuanMartinez-mf5bm Жыл бұрын
You missing make test between red circuits cables or don’t apply this tests?
@markgil9249
@markgil9249 Жыл бұрын
Doesn't mention what this test is for? We know but you have to mention this of you're explaining it.
@IAmThe_RA
@IAmThe_RA Жыл бұрын
To find out whether wires have the expected resistance value. Insufficient resistance means the wire insulation is bad and needs to be ditched as there risk of a ground fault or short circuit which can start a fire.
@Aquariun9iteMMare
@Aquariun9iteMMare 6 ай бұрын
Let me guess... you're asking for a friend?
@reymondrono982
@reymondrono982 Жыл бұрын
All Wires minimum passing 20 mega Om's ?
@shahbazsindhu6616
@shahbazsindhu6616 Жыл бұрын
No it's was wrong because you are missing something. After testing must discharge cable...
@ducatininja3866
@ducatininja3866 Жыл бұрын
Ive recently run 140mts of heat trace. I did a test and getting more than 20 megaohms. However when the heat trace is turned on its drawing 54amps. Any suggestions?
@Chevroletcelebrity
@Chevroletcelebrity Жыл бұрын
no
@CaltaTomas
@CaltaTomas Жыл бұрын
no :(
@jasonaldrich326
@jasonaldrich326 Жыл бұрын
Would be nice if they showed the sign on the meter...
@IWasNoah
@IWasNoah Жыл бұрын
pretty self explanatory
@IWasNoah
@IWasNoah Жыл бұрын
if you don’t know according to the IEC / ASNZS3000 it must be tested at twice rated voltage
@davidrosas2277
@davidrosas2277 Жыл бұрын
True… so far all the cables we’ve megg have tested at 660 M ohms in all our cables we have tested / installed here at my plant, which is what it shows on the megger she’s using in the demonstration, but like they said 20 M is a pass.
@moristaneo9447
@moristaneo9447 Жыл бұрын
you need to inject test also line to line and line1 to ground and line2 to gound. not only direct line1,2 to ground. need to separate
@BARTECglobal
@BARTECglobal Жыл бұрын
Hi! Thank you for watching the video. Most Meg sheets list L1-G, L2-G, but if they pass together they’ll pass separately.
@IAmThe_RA
@IAmThe_RA Жыл бұрын
​@@BARTECglobalwhat is her IG?
@bennyb6071
@bennyb6071 Жыл бұрын
interesting, didnt know you can megger semi conductors
@essabhuyian2296
@essabhuyian2296 Жыл бұрын
ও লেডি বিউটিফুল ই ন্স টাক টার
@ryanrahmat5980
@ryanrahmat5980 Жыл бұрын
where do I put the red and black wires for testing a cable that does not have a ground braid?
@BARTECglobal
@BARTECglobal Жыл бұрын
Hi @ryanrahmat5980! If the cable does not have a ground braid, then one of the cable conductors might be the grounding conductor. For example, a three-wire cords contain two current-carrying (Hot & Neutral) conductors and a grounding conductor. Check the cable type and please note, for single conductor non-shielded cables, insulation resistance testing cannot be performed because low voltage single conductors do not have a grounding conductor, shield or ground plane. Hope this helps and thank you for watching!
@impala1977
@impala1977 2 жыл бұрын
This is very helpful, thanks!
@BARTECglobal
@BARTECglobal 2 жыл бұрын
Hi @impala1977. We are glad you found it useful. Thanks for watching!
@tsmith3761
@tsmith3761 2 жыл бұрын
Damn, he’s sooo handsome 😍
@arisan4567
@arisan4567 2 жыл бұрын
It's better if you show the results of your testing in the video
@BARTECglobal
@BARTECglobal 2 жыл бұрын
Hi @arisan4567 You are right! We are taking notes for future videos. Thank you for watching and for sharing your feedback.
@jasonparkinson7621
@jasonparkinson7621 2 жыл бұрын
👍👍
@BARTECglobal
@BARTECglobal 2 жыл бұрын
👍🏽
@shamsadeenmohamed5074
@shamsadeenmohamed5074 2 жыл бұрын
Thanks alot..would you mind attaching a drawing for testing wirring
@BARTECglobal
@BARTECglobal 2 жыл бұрын
Hi! Thank you for watching. Please use the following link to download our design guide: www.bartec.de/en/downloads/heating-technology/engineering-tools/design_guide_iecex_final.pdf In page 36 you will find the "Tests and Commissioning" section. We hope this helps!
@exarep2616
@exarep2616 3 жыл бұрын
Excellent demonstration!
@BARTECglobal
@BARTECglobal 3 жыл бұрын
Glad you enjoyed it, Marcos!