ABB ACS380 7310 Fault code.
2:10
2 ай бұрын
Delta vfd programming.
4:36
6 ай бұрын
ABB VFD basics.
4:17
8 ай бұрын
ACS355 factory reset.
3:00
9 ай бұрын
POT fault in iG5A vfd.
1:09
Жыл бұрын
Пікірлер
@sunilpurohit4369
@sunilpurohit4369 16 күн бұрын
Nice guru ji
@pratibhajain3091
@pratibhajain3091 26 күн бұрын
Do u hv any insta ya wtsapp connection?
@pratibhajain3091
@pratibhajain3091 26 күн бұрын
Hi...can u tell me what to do for d108 eroor ..n i can not reset it aswell
@c4circuit
@c4circuit 25 күн бұрын
Please Share drive model and make.
@AshikenIslam
@AshikenIslam Ай бұрын
Please send atv312hu15nu parameters
@RajwinderSingh-wh2tg
@RajwinderSingh-wh2tg Ай бұрын
Pls send your contact no.... control card mai green light nhi chal rhi... Red chal rhi hai
@c4circuit
@c4circuit Ай бұрын
Drive k display par kya fault show ho rha hai
@RajwinderSingh-wh2tg
@RajwinderSingh-wh2tg Ай бұрын
@@c4circuit A5001
@c4circuit
@c4circuit Ай бұрын
Replace control card.
@RajwinderSingh-wh2tg
@RajwinderSingh-wh2tg Ай бұрын
@@c4circuit kha se milega... ya repair ho jaega
@c4circuit
@c4circuit Ай бұрын
Drive ka display change karke dekho agar phir bhi fault change nahi hotta to vfd ki details [email protected] par share karo.
@muhammadhamzanadeem4788
@muhammadhamzanadeem4788 Ай бұрын
Alarm 5001 Ka kya faulty hota ha sir
@c4circuit
@c4circuit Ай бұрын
Watch this video you will get your answer kzbin.info/www/bejne/mXisnZx6jJlkpdE
@mangaldev190
@mangaldev190 Ай бұрын
Sir 9902 2 set kiye h or on off push button use kiye h start karna per 0011 fault aa raha h
@c4circuit
@c4circuit Ай бұрын
This fault is related to motor id run. You can do one of two things 1. Set motor parameters, connect motor with drive and apply start command to drive. Make sure motor is not connected to load or 2. You can disable this fault by setting 9904=3 9910=0
@mangaldev190
@mangaldev190 Ай бұрын
@@c4circuit sir bahut bahut dhanyawad 🙏🙏♥️
@hmzanoor
@hmzanoor 2 ай бұрын
370 voltage per fault a jaata hak
@hmzanoor
@hmzanoor 2 ай бұрын
Sir A2005 fault under voltage a rha hi voltage adjust kesy hoga
@c4circuit
@c4circuit 2 ай бұрын
If your VFD is ABB AC355 or ACS550 1. Input supply kitni hai? 2. Parameter 107 mein DC voltage kitni show kar rha hai. 3. Agar fault on load vfd run karne par aa rha hai to soft start resistor ko bypass karne walli relay check karo. 4. DC bus bar k capacitor faulty ho sakte hai. 5. Igbt k converter section kankoi phase bhi open ho sakta hai.
@ansarisajid2740
@ansarisajid2740 2 ай бұрын
ABB ki 40 hp VFD 1310 ka alarm aaraha hai?
@c4circuit
@c4circuit 2 ай бұрын
Drive model?
@user-dz1nm6ed4y
@user-dz1nm6ed4y 2 ай бұрын
Hello! You can clarify about the parameter P103. What current should I set if the rated current of the motor is 5 Amperes when connected by a triangle. Should I set 2 times less than the overload current by 150 percent and divided by 2, that is, 3.75 Amperes? Or are the overload parameters set in section A?
@user-dz1nm6ed4y
@user-dz1nm6ed4y 2 ай бұрын
@@c4circuit Thanks for the reply. As I understood from the manual, the motor current min 0.00 max x2 is set in the P103. And if the current consumption if it exceeds the setpoint in P103 by 150%, then after 60 seconds, the error F 07 should occur and the drive will stop the engine or by 200%, then after 3 seconds. The current consumption of the engine is shown in D 103 3.2 A instead of 5A, as indicated on the engine when connected by a triangle. To be more precise, the 1.1kW 380 V motor consumes 2.9 A , and the 220V 5A triangle. I connected it to a triangle, since the frequency converter is from one phase to three 230 V. I set the setpoint 2.1 A in P 103 and the drive gave an error F07 a minute later and stopped the drive. It's a pity I didn't check the current with an external device. So it will turn out strangely if you set the setpoint to x2 of the nominal value of the engine. Have you checked the actual operation with the current set in the drive and the current consumption of the engine?
@c4circuit
@c4circuit 2 ай бұрын
Thank you we will check and get back to you soon.
@user-dz1nm6ed4y
@user-dz1nm6ed4y Ай бұрын
I checked it out. In this parameter, you need to set the rated current of the motors. If it is 5 A, we set 5A. There is no need to apply any multiplicities to the motor current.
@gopi_93
@gopi_93 2 ай бұрын
Thanks 👍
@c4circuit
@c4circuit 2 ай бұрын
Welcome
@MAVOORTECHMVR
@MAVOORTECHMVR 2 ай бұрын
Phone number
@sudipkandu2693
@sudipkandu2693 3 ай бұрын
🙏🙏🙏Thank you sir
@c4circuit
@c4circuit 3 ай бұрын
Most welcome
@samsamo720
@samsamo720 3 ай бұрын
Plz can you write what's dio you do here. Because we don't inderstand your language.
@c4circuit
@c4circuit 3 ай бұрын
In this video we were teaching our subscribers how they can run ATV12 vfd in Hand mode by pressing Mode key for 5 Seconds and how to disable OPL fault by setting flt > opl to No.
@SanaDawar-te5jp
@SanaDawar-te5jp 4 ай бұрын
@c4circuit
@c4circuit 4 ай бұрын
Thanks
@hansrasirj9920
@hansrasirj9920 4 ай бұрын
3181ka bhi btao
@c4circuit
@c4circuit 4 ай бұрын
Check IGBT module and IGBT gate driving circuit.
@Saidun.ee1
@Saidun.ee1 4 ай бұрын
Please share your number
@ShahieryarBhatti
@ShahieryarBhatti 5 ай бұрын
ASalaam alaikum ustad ji Maine kam sikhana hai please
@TechnicalMrKapil
@TechnicalMrKapil 5 ай бұрын
Sir reset nahi ho raha he
@explorenature4363
@explorenature4363 5 ай бұрын
❤❤❤❤❤
@sunilpurohit4369
@sunilpurohit4369 5 ай бұрын
Sir ji aap ke number kya h
@sunilpurohit4369
@sunilpurohit4369 5 ай бұрын
Nice sirji
@dr.brcfanarmy6441
@dr.brcfanarmy6441 7 ай бұрын
ACS550 ka v circuit explain karenge please
@c4circuit
@c4circuit 7 ай бұрын
Which section?
@user-xb6rc2ku6u
@user-xb6rc2ku6u 7 ай бұрын
کو عربی
@mosatamajrt6252
@mosatamajrt6252 7 ай бұрын
سلام عليكم
@c4circuit
@c4circuit 7 ай бұрын
This is not a parameter issue, it is a hardware problem you have to replace the control card or 8 pin eprom with the new one.
@hitendrasinhjadeja5831
@hitendrasinhjadeja5831 Жыл бұрын
Display kitne ka aata hai or kaha se milega
@c4circuit
@c4circuit Жыл бұрын
Ye ACS355 ka hi display hai jo company drive k sath provide karti hai. Agar apko apko new display chahiye to please contact your local ABB channel partner.