@sophiali8782
@sophiali8782 20 сағат бұрын
Thank you. This was helpful!
@GeraldsLyfeProjects
@GeraldsLyfeProjects 7 сағат бұрын
Glad it was helpful!
@gubbool
@gubbool Күн бұрын
Can be done, but the math seems faulty. You chose to purchase a $500 chargeverter so you could charge your batteries while selling power back to the grid. And you use the F-150 to run the chargeverter. Thus, basically using one battery to charge another. At some point the F-150 needs to be recharged. I’m going be to surprised that: when the sun is out that the Sol-Ark will power the house load, charge the F-150, charge the batteries, AND still have sufficient excess to sell back to the grid. (I believe) The F-150 can be connected to the Sol-Ark to power a house and recharge the batteries without the chargeverter.
@GeraldsLyfeProjects
@GeraldsLyfeProjects Күн бұрын
I think that I have made at least 1 or 2 videos addressing all of your statements. But you did not ask any questions…, like “Are you charging the F150 for free?” The answer is “Yes”. I charge for FREE while I’m at work. If you check my latest video, you’ll see why I’m connecting the F150 to the Chargeverter instead of connecting directly to the Sol Ark: kzbin.info/www/bejne/gHexhZqld6upbNUsi=27Rgbz8dyv_AyPB_ But I’ll explain it so that everyone that may have read your statements will understand. The F150’s Pro Power Onboard is only rated for 30 amps or 7,200 watts which limits me to 30 amps for my house loads if directly connected to the Sol Ark 15k. However, by connecting the F150 directly to the batteries using the EG4 Chargeverter, I now have: 50 amps/12,000 watts (No Solar) 75 amps/18,000 watts for 5 sec. (No Solar) Up to 62.5 amps/15,000 watts (With Solar) Up to 100 amps/24,000 watts for 10 sec. (With Solar) So, when I get home from work, it’s just like turning on the SUN again…, but at night! Thanks For The Comment!!!
@gubbool
@gubbool 4 күн бұрын
Thanks… a timely video for me. 2 years back I set up a sol-ark off-grid system in a cabin. Now I’m moving that simple 1 sol-ark - 1 battery - 1 generator to my new build. That old system functioned so well that I seldom put my hands on it. I forgot everything that I once knew. The new system has 2 sol-arks, 8 Kilovault 7.5 HAB batteries, and 2 14kw gens… This is a great refresher course for me. As well as a great tool for new users.
@GeraldsLyfeProjects
@GeraldsLyfeProjects 4 күн бұрын
That’s Good To Hear!!
@Tobias-uf2oj
@Tobias-uf2oj 10 күн бұрын
Thanks for the video. Do you need to do anything special to keep the Sol Ark and Chargeverter from charging at the same time? I assume the Sol Ark is using closed loop comms and the Chargeverter charges by voltage?
@GeraldsLyfeProjects
@GeraldsLyfeProjects 10 күн бұрын
Yes, the closed loop communication is maintained between the Sol Ark and the eFlex batteries. The voltage is used to either maintain or charge the batteries. The Chargeverter is connected to the Victron box and then to the bus bars of the battery rack. I usually only hook up the Chargeverter at night when there’s no solar and the batteries are around 60-70% charge. So, I don’t have to make any adjustments on the Sol Ark. Even with Solar during the daylight hours, the capacities are: Sol Ark 15k- 275 amps Batteries 105 amps/each (discharge & charge) Rack bus bars 500 amps/each Victron dist. Bus bar 1.000 amps The EG4 Chargeverter’s capacity is only 100 amps but I’ve only seen it get to maybe 97 amps. Thanks For The Comment!
@Tobias-uf2oj
@Tobias-uf2oj 10 күн бұрын
@GeraldsLyfeProjects thanks for the detailed reply. Cool setup. Do you have somewhere to charge the truck for free during the day? Also, have you found the house bats BMS limits charge current in the cold or when they are near 100%? Maybe not an issue in your climate not sure.
@GeraldsLyfeProjects
@GeraldsLyfeProjects 10 күн бұрын
@@Tobias-uf2oj Man Tobias…, you always ask the right questions! Yeesssssss!!! I charge for FREE at work! Anybody reading this and your job allows for FREE EV CHARGING while you’re working…, go get an EV. (But don’t get fired) If you also have a server rack battery bank, go get the cheapest Ford F-150 Lightning with Pro Power Onboard you can find.
@Tobias-uf2oj
@Tobias-uf2oj 10 күн бұрын
@@GeraldsLyfeProjects haha, thanks, I try :) Love the videos, thanks for sharing your setup!
@ThunderandLightningEvPickup
@ThunderandLightningEvPickup 13 күн бұрын
Cool experiment
@GeraldsLyfeProjects
@GeraldsLyfeProjects 13 күн бұрын
Thanks! I’ve got more coming
@GeraldsLyfeProjects
@GeraldsLyfeProjects 16 күн бұрын
This is how I numbered the Westinghouse wgen9500 ATS pin out connection. With the notch being at the top position (12:00 position) and counting the pins in a clock wise order, the order is pin 1, 2, 3, 4, 5, 6, with pin 7 in the middle position. Pin 1 is 21.2 volts w/gen on (run signal 1) Pin 2 is 11.7 volts w/gen on (run signal 2) Pin 3 is a ground (Do Not Use w/Gscm mini) Pin 4 if connected to pin 5 starts/stop generator Pin 5 if connected to pin 4 starts/stop generator Pin 6 is the positive battery Pin 7 is NOT USED Pin 1 is attached to 9 (L1) on gscm mini Pin 2 is attached to 10 (N) on gscm mini Pin 3 is NOT USED. (Use battery ground for gscm mini’s ground connection) Pin 4 is attached to 13 on the gscm mini Pin 5 is attached to 14 on the gscm mini Pin 6 is attached to 2 (DC+) on gscm mini Port 1 (DC-) on gscm mini should be attached directly to battery negative. Do not use pin 3 because pin 3 will make the generator keep turning on and off. 1 of the 2 wire start wires needs to be split into 2 wires and attach to the gscm mini at 3 (+) on gscm mini and also at 6 (relay option) on the gscm mini. I don’t think it matters which wire you use from the 2 wire start. The 2nd wire of the 2 wire start is attached to 5 (man. start) on gscm mini.
@steveharris1476
@steveharris1476 14 күн бұрын
@@GeraldsLyfeProjects thanks for the detail! Can you post a link to where to buy the ATS wire/connector?
@GeraldsLyfeProjects
@GeraldsLyfeProjects 13 күн бұрын
@@steveharris1476 This is the Amazon Link: www.amazon.com/dp/B085XK6D8G?ref=ppx_pop_mob_ap_share
@quickquote1568
@quickquote1568 17 күн бұрын
The chargeverter's maximum output voltage is not high enough to fully charge a 48 Volt LFP battery pack.
@GeraldsLyfeProjects
@GeraldsLyfeProjects 16 күн бұрын
Is it because of my settings or the capacity of the Chargeverter?
@steveharris1476
@steveharris1476 17 күн бұрын
Hi Gerald, I am using a GSCM- WiFi to connect between a WGen9500DFc and an EG4 3kW inverter. I'm interested in the details of how you used the ATS 7 pin plug to connect the GSCM wiring?
@GeraldsLyfeProjects
@GeraldsLyfeProjects 16 күн бұрын
This is how I numbered the Westinghouse wgen9500 ATS pin out connection. With the notch being at the top position (12:00 position) and counting the pins in a clock wise order, the order is pin 1, 2, 3, 4, 5, 6, with pin 7 in the middle position. Pin 1 is 21.2 volts w/gen on (run signal 1) Pin 2 is 11.7 volts w/gen on (run signal 2) Pin 3 is a ground (Do Not Use w/Gscm mini) Pin 4 if connected to pin 5 starts/stop generator Pin 5 if connected to pin 4 starts/stop generator Pin 6 is the positive battery Pin 7 is NOT USED Pin 1 is attached to 9 (L1) on gscm mini Pin 2 is attached to 10 (N) on gscm mini Pin 3 is NOT USED. (Use battery ground for gscm mini’s ground connection) Pin 4 is attached to 13 on the gscm mini Pin 5 is attached to 14 on the gscm mini Pin 6 is attached to 2 (DC+) on gscm mini Port 1 (DC-) on gscm mini should be attached directly to battery negative. Do not use pin 3 because pin 3 will make the generator keep turning on and off. 1 of the 2 wire start wires needs to be split into 2 wires and attach to the gscm mini at 3 (+) on gscm mini and also at 6 (relay option) on the gscm mini. I don’t think it matters which wire you use from the 2 wire start. The 2nd wire of the 2 wire start is attached to 5 (man. start) on gscm mini.
@jaysonstebbins2539
@jaysonstebbins2539 23 күн бұрын
Just inherited the same one. Thank you. Doing the same to my house. What all can you run off yours? I have a carrier 3 ton heat pump. Any issues with the total harmonic distortion? I hear its high on this particular model.
@GeraldsLyfeProjects
@GeraldsLyfeProjects 22 күн бұрын
Yes, the total harmonic distortion for this generator is rated as high as 23% which is not good for sensitive electronics. The WGEN9500 was able to start and run my 3.5 ton air conditioner but not on the 1st initial try. The 2nd try didn't require as much starting amperage which allowed the air conditioner to run. However, you might say that I am cheating, because I am really just routing the generator's power through a Sol Ark 15k Inverter to mostly charge the rack mounted batteries in my solar system.
@jaysonstebbins2539
@jaysonstebbins2539 22 күн бұрын
@GeraldsLyfeProjects makes sense. Thanks alot!
@jeffmiller2806
@jeffmiller2806 Ай бұрын
I found your other video where you show how to set up the two wire relay. That’s cool. I’m still interested in your feedback on the THD % though. I have heard that some folks with EG4 inverters have had issues when running non-inverter generators a.k.a. “dirty power “ generators.
@GeraldsLyfeProjects
@GeraldsLyfeProjects Ай бұрын
WOW…, 23% “Total Harmonic Distortion”…, I did not know that! I guess that is testament to the “Quality, Workmanship & Consistency” of the Sol Ark 15K in comparison to the other “Hybrid Inverters”. The Westinghouse wgen9500 starts at around 64hz with NO LOAD and as I start to put loads on the generator the frequency lowers, I can monitor the “Total Harmonic Distortion” of the wgen9500 generator n the Sol Ark 15k’s battery screen (located in the lower, middle part of the screen). Right around 50% of the wgen9500’s normal running capacity, it remains close to 60hz. In addition, The Sol Ark 15k’s “TIME OF USE” further allows for a more consistent “Total Harmonic Distortion” by allowing me to send most the wgen9500’s load to charging the batteries (which is a consistent and easily maintained load) while I lower load requirements to the house using the Leviton LWHEM-2 to shut off non essential circuits. For example 4,000 watts to charging the batteries and maintain less than or equal to 1,000 watts to the house loads until the sun comes out or the clouds dissipate. HOWEVER, THE EG4 CHARGEVERTER HAS MADE ALL OF THAT…, “A THING OF THE PAST!!” I’ll be putting out a video on the EG4 Chargeverter soon. Thanks For The Comment And Keep’em Comin!!
@jeffmiller2806
@jeffmiller2806 Ай бұрын
I found your other video where you show how to set up the two wire relay. That’s cool. It’s probably cheaper to just have a battery tender to keep everything charged and ready to go versus burning 20 minutes of gas each week. The real benefit is having the ability for the generator to self start when the batteries reach a certain level. I know you briefly mentioned what it might look like if it were running at night. That would be a cool video add-on to actually see that demo when you exceed the output of the generator. Keep the videos coming you’re showing content that no one else is.👍
@GeraldsLyfeProjects
@GeraldsLyfeProjects 16 күн бұрын
Check out this video: kzbin.info/www/bejne/hKPRl6KorZaofKssi=zx7taexwX2Rxychx
@jeffmiller2806
@jeffmiller2806 Ай бұрын
Interesting video and demo! Did you get the 2-wire start to work with your Westinghouse generator? If so how did you wire it all up? Also are you concerned with the generator’s 23%THD? I thought Sol-ark says it should be below 15% Thanks
@GeraldsLyfeProjects
@GeraldsLyfeProjects Ай бұрын
WOW…, 23% “Total Harmonic Distortion”…, I did not know that! I guess that is testament to the “Quality, Workmanship & Consistency” of the Sol Ark 15K in comparison to the other “Hybrid Inverters”. The Westinghouse wgen9500 starts at around 64hz with NO LOAD and as I start to put loads on the generator the frequency lowers, I can monitor the “Total Harmonic Distortion” of the wgen9500 generator n the Sol Ark 15k’s battery screen (located in the lower, middle part of the screen). Right around 50% of the wgen9500’s normal running capacity, it remains close to 60hz. In addition, The Sol Ark 15k’s “TIME OF USE” further allows for a more consistent “Total Harmonic Distortion” by allowing me to send most the wgen9500’s load to charging the batteries (which is a consistent and easily maintained load) while I lower load requirements to the house using the Leviton LWHEM-2 to shut off non essential circuits. For example 4,000 watts to charging the batteries and maintain less than or equal to 1,000 watts to the house loads until the sun comes out or the clouds dissipate. HOWEVER, THE EG4 CHARGEVERTER HAS MADE ALL OF THAT…, “A THING OF THE PAST!!” I’ll be putting out a video on the EG4 Chargeverter soon. Thanks For The Comment And Keep’em Comin!!
@TKO67
@TKO67 Ай бұрын
Whay brand model gen are you using?
@GeraldsLyfeProjects
@GeraldsLyfeProjects Ай бұрын
I’m using a Westinghouse wgen9500 but you can use any “Transfer Switch Ready” portable generator which means the generator has a connector with 7 to 9 pins. You’ll have to figure out which pins start and stop the generator. The Westinghouse generators are NOT “true 2 wire start/stop” generators. I had to purchase a GSCM Mini to make it work. But, I think the Duromax and Genmax generators only require one wire each for 2 pins for their 2 wire start/stop to work. Here is a video of my setup. kzbin.info/www/bejne/lWOVgnSAjtyUfKcsi=M0ordlNTJAX4q2Fm
@GeraldsLyfeProjects
@GeraldsLyfeProjects 2 ай бұрын
Thanks For The Comment! Check out these videos: kzbin.info/www/bejne/gGXZpp2Mot5nb6ssi=Pnr4grobTSkDbDmN kzbin.info/www/bejne/hKPRl6KorZaofKssi=zx7taexwX2Rxychx
@Tobias-uf2oj
@Tobias-uf2oj 2 ай бұрын
Thanks so much for making this! I have a Sol-Ark 15K too (it's how I found your video!) and I'm hoping to find a way to disconnect neutral from the grid when flipping over to the truck, like you mention around the 9 minute mark. I'm not an electrician either and I'm not sure about disconnecting the ground from the truck. From what I understand, the purpose of the bond is to force the fault current to flow back through the truck, which might not happen if the truck is not grounded? The issue is the 4 wire double throw transfer switches I've found are sbout 3x the cost. Maybe worth it I'm not sure. Anyways thanks again for making this and explaining how the truck snd house are wired together I really appreciate it.
@GeraldsLyfeProjects
@GeraldsLyfeProjects 14 күн бұрын
Check out this video: kzbin.info/www/bejne/hKPRl6KorZaofKssi=zx7taexwX2Rxychx
@Tobias-uf2oj
@Tobias-uf2oj 2 ай бұрын
This is amazing! Super clean install. What is the model of the transfer switch? I assume it is a three pole with the ground/neutral bond on the grid side, to not cause an alarm on the F-150?
@GeraldsLyfeProjects
@GeraldsLyfeProjects 2 ай бұрын
Thanks For The Comment! I just post a new video about how the F-150 is connected. The transfer switch is a GE 200 amp transfer switch.
@Tobias-uf2oj
@Tobias-uf2oj 2 ай бұрын
I found your other video of the original setup and it looks like the ground/neutral bond is not broken when the trsnsfer switch is flipped to GEN. I take it your truck inverter does not shut off with a fault code if it's connected to the system with an existing ground/neutral bond? Or did you find another way to address this? Here's the other video I found: kzbin.info/www/bejne/p33ao2ODjLR6Z8kfeature=shared EDIT: I started writing this before I saw your comment a few min ago, I will check out that video, thanks so much!
@GeraldsLyfeProjects
@GeraldsLyfeProjects 2 ай бұрын
Check out these videos: kzbin.info/www/bejne/gGXZpp2Mot5nb6ssi=Pnr4grobTSkDbDmN kzbin.info/www/bejne/hKPRl6KorZaofKssi=zx7taexwX2Rxychx
@zl1booker
@zl1booker 2 ай бұрын
thank you
@GeraldsLyfeProjects
@GeraldsLyfeProjects 2 ай бұрын
You're welcome
@TheMathMax
@TheMathMax 3 ай бұрын
Thats what i'm striving for. looks good!
@GeraldsLyfeProjects
@GeraldsLyfeProjects 14 күн бұрын
Thanks for the comment
@greglecrone2180
@greglecrone2180 3 ай бұрын
Excellent video
@GeraldsLyfeProjects
@GeraldsLyfeProjects 3 ай бұрын
Thanks For The Comment
@GeraldsLyfeProjects
@GeraldsLyfeProjects 4 ай бұрын
Thanks For The Comment!! I did not modify the 30 amp cord coming from the Lightning to the 30 amp inlet box. Most of the inlet boxes come with a 2 wire grounding bus bar and a green wire already attached to one of the bus bar connections. I connected the ground wire coming from the Sol-Ark to the other bus bar connection. I did NOT connect the ground from inlet socket to the bus bar connections because the Lightning has GFCI protection to shut off it’s power in case of a ground fault. I connected the Lightning to a transfer switch that switches from grid power to the Lightning and then feeds the grid connection of the Sol-Ark. I AM NOT AN ELECTRICIAN! So, please consult with an electrician and always safety first!
@GeraldsLyfeProjects
@GeraldsLyfeProjects 4 ай бұрын
Thanks For The Comment!!
@GeraldsLyfeProjects
@GeraldsLyfeProjects 4 ай бұрын
I have 6 of the Fortress Power Eflex batteries and they are 5.4kW each which comes to about 32.4kW of battery power. Thanks For The Comment!!
@byronholman9228
@byronholman9228 4 ай бұрын
👍🏾👍🏾
@GeraldsLyfeProjects
@GeraldsLyfeProjects 14 күн бұрын
Thanks
@dirtdiver2389
@dirtdiver2389 4 ай бұрын
Nice setup. How much battery storage do you have and what batteries did you go with?
@GeraldsLyfeProjects
@GeraldsLyfeProjects Ай бұрын
I have 6 Fortress Power eFlex batteries at 5.4kW each for a total of 32.4kW.
@curiousumscientia3648
@curiousumscientia3648 5 ай бұрын
Excellent setup. On the cable between lightning to house, did you make this? Did you use the ground wire or left it on connected on this cable? Also do you have the sol-ark configured not to backfeed the grid or are you connecting the ford input as a generator connection on the sol-ark?
@GeraldsLyfeProjects
@GeraldsLyfeProjects 15 күн бұрын
I did not make the cord. The ground is not connected to the receptacle or the house’s ground. I have a separate video on how to connect the Pro Power Onboard to a house. I setup the Sol Ark 15k with the generator connected to the grid. So, the Sol Ark 15k will not sell back to the grid. Check out this video: kzbin.info/www/bejne/hKPRl6KorZaofKssi=zx7taexwX2Rxychx