Your voltage indicator is it a UNI-T ?
@burridgeelectricalyourloca2075
@burridgeelectricalyourloca2075 Ай бұрын
I think that one is a TIS 👍🏻 Fluke was my favourite voltage indicator
@Dog-whisperer7494
@Dog-whisperer7494 Ай бұрын
Wow someone’s done a proper EICR for a change.👍 point of note the arethusa reading should be 1.76 times greater than the line and neutral. You did a good job there mate .👍
@burridgeelectricalyourloca2075
@burridgeelectricalyourloca2075 Ай бұрын
Thanks for the info!
@michaelcostello6991
@michaelcostello6991 Ай бұрын
nice job
@Sellmyowngranmother
@Sellmyowngranmother 5 ай бұрын
Hi Did you say 25mm sub main ? Why so big ? Thanks
@burridgeelectricalyourloca2075
@burridgeelectricalyourloca2075 5 ай бұрын
Alright , 25mm cable ran in due to the long run from the front of the house where the origin is down to the bottom of the garden , the annex had electric heating , electric water heater , shower , sockets and lighting so by calculation of cable length , load and VD the CSA come in at 25mm
@Sellmyowngranmother
@Sellmyowngranmother 5 ай бұрын
@@burridgeelectricalyourloca2075 you know you’re onions….tell me can you have another metre in the annex
@train4905
@train4905 Жыл бұрын
Exellent
@burridgeelectricalyourloca2075
@burridgeelectricalyourloca2075 Жыл бұрын
Thanks
@szpitalpsychiatrycznywjoze5011
@szpitalpsychiatrycznywjoze5011 Жыл бұрын
Bezpiecznik powinien być zmieniony na odpowiedni do przekroju przewodu
@burridgeelectricalyourloca2075
@burridgeelectricalyourloca2075 Жыл бұрын
Yes your correct, this cable is 1.5mm flex rated at 16A current ,so the 13A fuse is suitable 😉
@szpitalpsychiatrycznywjoze5011
@szpitalpsychiatrycznywjoze5011 Жыл бұрын
@@burridgeelectricalyourloca2075 ciekawe W Polsce 1,5mm jest na max 10A
@burridgeelectricalyourloca2075
@burridgeelectricalyourloca2075 Жыл бұрын
​@@szpitalpsychiatrycznywjoze5011 dzien dobry, that is interesting mate , in the UK the BS7671 wiring regulations we work to shows that 1.5mm is rated for 16A and less depending on installation methods etc
@Sunshinesniles
@Sunshinesniles Жыл бұрын
Fact I'm married to a plasterer #1 messiest, laziest, not pickin. Up after himself EVER onthis PLANET PLASTERS are the messiest Make No Mistake
@burridgeelectricalyourloca2075
@burridgeelectricalyourloca2075 Жыл бұрын
It is a messy job I must admit , however the plasterers I know normally tidy up ,but this is a right mess 🤣
@Sunshinesniles
@Sunshinesniles Жыл бұрын
@@burridgeelectricalyourloca2075 understand lol
@Megaderpus_Maximus
@Megaderpus_Maximus Жыл бұрын
I wire up robots for my robotics team. This is when mechanical tries wiring moving parts and doesn't leave slack for the dammed thing to move.
@ded-pihto
@ded-pihto 6 жыл бұрын
anton burridge, hello. Is it possible to get a job for me in UK as a foreign citizen? I have a plastering, drywall, painting and electrician skills.