Wood Steel Composite Nolan Beam
3:25
Foundation Problems and Fixes
41:11
2 жыл бұрын
Foundation Wall Problems & Repairs
41:11
Cracked Ceiling Inspection
8:18
3 жыл бұрын
How to size an isolated footing
15:51
Modified Truss Inspection
3:58
3 жыл бұрын
Cracked or notched joist
12:46
4 жыл бұрын
Notched
9:20
4 жыл бұрын
Repair footer
9:20
4 жыл бұрын
Repair joist
12:45
4 жыл бұрын
Пікірлер
@mikeroberts1754
@mikeroberts1754 19 күн бұрын
What kind of steel straps do I buy to use for my basement
@DennisNy75
@DennisNy75 Ай бұрын
Grate video.. taking your number down
@TheHeavyend81
@TheHeavyend81 Ай бұрын
Well, saying you have come up with the idea is a bit of a stretch, straps such as this are widely available in the building industry (at least in the UK). My concern would be when the ceiling board goes up, this method means you would have to hack into the board to avoid the ridge of the securing bolts, also there is considerabled length where you would be unable to affix the board due to the strap. Really to make this fully work the stap (and bold heads) need to be recessed a little and a small sister baton fixed along the length of the strap, each side so a ceiling board could be affixed nice and flush. Idea is good but not fully thought through.
@dagconst1
@dagconst1 Ай бұрын
Do they come with engineering. As local inspectors would ask
@OpalKiss
@OpalKiss Ай бұрын
Would this work on a joist that is already cracked diagonally?
@KBLogistics-i2h
@KBLogistics-i2h 2 ай бұрын
Very Good!!
@Ccb516lira
@Ccb516lira 2 ай бұрын
I cold see this mikimouse shit since him start drillwith Miki mouse drill...this is so unprofetionall
@garygogolinski2878
@garygogolinski2878 2 ай бұрын
Might water come into house when drilling holes in blocks?
@haoranzheng7846
@haoranzheng7846 3 ай бұрын
Hi is there a way to repair the notched on the upper side?
@brianherald5756
@brianherald5756 4 ай бұрын
This is an absolutely great way to fix block walls Iv done it and it’s cheap and easy to do and will last a long time if every step is done correctly,thank you for saving my house
@davidwillis5016
@davidwillis5016 Ай бұрын
What do you consider cheep? What year did you do it and what was the cast of material at that time?
@lou704
@lou704 4 ай бұрын
Outstanding.
@brianhiggins7599
@brianhiggins7599 6 ай бұрын
Do you include the bolts with the straps ?
@nolanengineeringpllc2713
@nolanengineeringpllc2713 6 ай бұрын
Yes, we do.
@sevenheadedweasel
@sevenheadedweasel 6 ай бұрын
I bet it can probably take a similar bearing to a regular post, but what about moment / overturning? Seems like it would be pretty weak to that.
@nolanengineeringpllc2713
@nolanengineeringpllc2713 6 ай бұрын
The piers with the 12" x 12" top ground plate "squeeze" the ground and have excellent later load carry capability. The piers without the ground plate have a "+" shaped load fine installed at the top to withstand lateral loads. However, in all cases, bracing the posts with diagonal bracing is recommended especially if the posts are long.
@kurthellenberg
@kurthellenberg 6 ай бұрын
The only one I saw on your site is non frost 24" free standing, but the vid looks longer but not 4' and building off the house?
@BryanWaugaman
@BryanWaugaman 6 ай бұрын
@@kurthellenberg we are selling an extension that would put you below a 4' frost line. the kit is labeled frost protected on our website and it is a combination of a 36" auger and a 24" extension. If you are attaching the structure to the house you would want the frost protected variant but if you are not and it will be free standing you can use the non frost protected. Hope this helps!
@vincedalessandro1955
@vincedalessandro1955 6 ай бұрын
How much of load will this pier carry?
@nolanengineeringpllc2713
@nolanengineeringpllc2713 6 ай бұрын
The shorter pier (less than 4') with the 12" x 12" load plate can take up 1400# in clay and 6200# in sand. I would recommend designing for 1/2 of these loads. For the pier without the plate, it has an ultimate load in non-clay soil of 1400# - 1500# but recommend a design load of 800#.
@go-toolzreviews
@go-toolzreviews 6 ай бұрын
Excellent
@paulpickard8327
@paulpickard8327 7 ай бұрын
This looks like just what I need...except in my case the wall that needs a fix is supporting a poured concrete slab porch that is above. How could I anchor the straps to that slab? Since the slab sits directly on the block wall I don't have the tension of the steel strap like you do with wood joists. Any ideas?
@BryanWaugaman
@BryanWaugaman 7 ай бұрын
If the wall is just bowing and not slipping out from under the slab at the top, then he does not have to attach to the slab. If he needs or wants to attach to the slab, he could drill holes in the edge of the slab and use one of the bolts. He may get luck if the slab is 4” thick and use the hole that is designed to go into the 4” top block, if not, he could always drill another hole which I think was 7/16”? -Rich
@martinw245
@martinw245 7 ай бұрын
So what if you can't access the underneath of the joist because there's a ceiling below?
@nolanengineeringpllc2713
@nolanengineeringpllc2713 7 ай бұрын
Depending on the situation, the strap can also be applied to the side. We now have a few different options for joist repair if you visit our website - nolanstructuralproducts.com or you can use our contact form to send us a picture and we can provide recommendations.
@zackdreamcast
@zackdreamcast 7 ай бұрын
little concerning that you have real photos for the metal beams and the carbon fiber... then when you go to the metal straps is a computer generated model...
@nolanengineeringpllc2713
@nolanengineeringpllc2713 7 ай бұрын
You're viewing a very old video. Please see some of our newer videos for basement wall strap installations.
@patty109109
@patty109109 7 ай бұрын
Discussion of cracking walls early in vid is excellent. I’d never thought of that about trees but of course it’s true: they are very heavy and forces are not purely vertical.
@fredrezfield1629
@fredrezfield1629 8 ай бұрын
can you elaborate 4:25 looks like my own scenario with the exception of plumbing is on top (bathroom the second floor)
@fredrezfield1629
@fredrezfield1629 8 ай бұрын
can i hav ea shower drain on top of the joist? i am working with a 32 by 48 shower base where the hole is in the middle but it is also going to be on top of the floor joist is there a solution ?
@nadakeenr7715
@nadakeenr7715 8 ай бұрын
at 11 min you said 20" x 20" x 12" thick footing (where did you get the 12" from?)
@nolanengineeringpllc2713
@nolanengineeringpllc2713 8 ай бұрын
12” is a safe thickness for footings up to at least 24” x 24”. The thickness of the footing is governed by the punching shear, in other words you do not want the post to punch through the footing. At 12” you are safe for smaller footings, In fact you could potentially go all the way down to the code minimum of 6” but usually I see, 8”, 10” or 12”. To determine the actual footing thickness takes a bit of work. Hope this helps.
@jdub7771
@jdub7771 9 ай бұрын
Nice product
@daenku32
@daenku32 10 ай бұрын
Getting ready to buy a home built in 1930. One long horizontal crack in basement. So this is helpfull.
@manderson5397
@manderson5397 10 ай бұрын
these walls like many others NEED to be hand dug out, exterior waterproofing dude because that would reduce lateral soil pressure acting upon the walls and remove any possible underground tree roots AND properly waterproof all of the EXTERIOR cracks in walls!!! (backfilled with all gravel) Example-- tree limb lands on your roof during a storm and causes damage to roof and water begins to enter, what are YOU going to do? Install some braces and foam up in the attic or are you going to remove the tree branch off the roof and repair the damaged roof on the exterior? smh
@gkogel
@gkogel 10 ай бұрын
Do you have anything that works for round pipe?
@jdub7771
@jdub7771 9 ай бұрын
They show you at 1:30 into the video
@gkogel
@gkogel 9 ай бұрын
Not really.. that's a round pipe with square foot welded to it. I asked about just round pipe.
@jdub7771
@jdub7771 9 ай бұрын
@@gkogel ahhh I gotcha
@homebuildersllcdesignbuild3664
@homebuildersllcdesignbuild3664 11 ай бұрын
Great Video thank you!! 🙏
@jayd1008
@jayd1008 11 ай бұрын
can you notch the center of the joist if you sister the top portion ?
@brodyllc
@brodyllc 11 ай бұрын
that’s an impact driver not a hammer drill
@theok4712
@theok4712 11 ай бұрын
Very good video on explaining how to calculate column footings. Interesting product using a large steel plate.
@TheFam-w2o
@TheFam-w2o 11 ай бұрын
Keep It Real Now!!! God Forbid You Question A Engineer Because They Know It All!!! ANY CRACKS In Your Basement Walls Need To Be Adressed Right Away , Because Where There's One Crack There Are More!!! That Means More Places For Water To Seap In!!! Which In Turn Fills The Blocks With Water Which In Turn Will Rott The Blocks From The Inside Out!!! Which By The Way, When The Frost Level Drops It Freezes The Water Logged Blocks!!! Which By The Way!!! As It Freezes The Ice Expands And Retracts!!! Which By The Way!!! Tends To Weakin The Blocks, Which Weakins The Tegrety Of The Wall!!! What Happens Then You Ask??? Due To The Weight Of The House!!! And The Pressure From The Ground Itself Around The Walls!!! And All The Water Run Off And Ice!!! The Walls Bow In!!! Who Wants To Just Stop The Bowing Walls??? Which By The Way!!! Is Technically A Quick Temperary Fix!!! And Yes You Can Get The Walls Straight Again!!! You Have To Dig Around The Outside Like A Water 💧 Proof!!! While You Have The Ground Open!!! What Ever Wall You Are Working With??? Start In The Corner!!! Use A 40 ton Bottle Jack!!! 2' From The Wall!!! Jack The House VERY SLOW ( Listen for unwanted cracking sounds!!! ) Just Enough To Barely Sunlight!!! You Should Have Pre -Driiled On The Basement Floor Against The Walls Every 3', 3" x 4" Deep!!! Cut Some Pieces Of 2x10x16 Blocks And Screw Them Into The Floor Joices So The Joicies Don't Roll When Jacking!!! Now!!! My Boss And I Fabbed Our Own Jack Tub That Holds Our Special 100 Ton Jack Is Specifically For Pushing Walls From The Inside!!! As You Slowly Push The Wall You Need Keep Checking The Wall With A 4' level Horizontally!!! Once The Lower Half Touches The Top And The Bottom!!! Put Your 3"x7' Beams In The Hole On The Floor And Bolt The Top Half To The Floor Joices Continue Áll The Way Around The Bad Walls!!! Don't Forget To Fill Any And Áll Cracks!!! Once You Finish The Walls From Inside!!! Go Outside While The Walls Are Exposed!!! Grind Out And Fill Any And Áll Cracks With Type S Mortar, Once It Dries, Spread Tar On The Wall, Put Visqueen And 4'x8'x2" Styrofoam!!! Where I'm From??? Inspectors Won't Let You Backfill With Dirt!!! So We Start With 2' Of Peat Gravel Over The Drain Tile, Then 3" Crushed Concrete!!! 2' Of Top Soil And Clean Up And Be Gone!!! I Have Been Doing This Since I Was 15yrs Old!!! I'm 55yr Now, I've Done Rebuilt Or Repaired Well Over A 1,000 Of These And Have Not Ever Had A Call Back!!! I Love What I Do Because At The End Of The Day??? I Know I Saved Someone's House And Or Bank Account Down The Line!!! Just Saying That There's No Way I Would Use Any Of The 3 Fixes He's Talking About, Just Pay The Extra Money A Get It Done Right The First Time!!!
@daltondasilva2476
@daltondasilva2476 Жыл бұрын
can I repair 6 joists in a role using this kit?
@totallygallactic3426
@totallygallactic3426 Жыл бұрын
what if you can not access the top of joist?
@unds85
@unds85 Жыл бұрын
That strap restores "FULL" strength of the joist?
@nolanengineeringpllc2713
@nolanengineeringpllc2713 Жыл бұрын
Yes, and in some cases it will actually make the joist stronger than it was in its original state as steel is much stronger than wood.
@lningzhang6655
@lningzhang6655 Жыл бұрын
very useful knowledge!! recently renovating my kitchen, plan to run a 3" drain pipe through 5 solid wood joists of 8", the holes that run the drain pipe are over 3" Dia, so I want to use the metal joist reinforcement plate to support the joists. it is possible? Thanks
@isaacneitzell2897
@isaacneitzell2897 Жыл бұрын
Are those straps 0.31” thick (over 1/4” thick)? They look thin but maybe that’s just for illustration?
@natej6671
@natej6671 Жыл бұрын
This makes absolutely no sense ... I didn't know why I keep replaying it :)
@chadkues1592
@chadkues1592 Жыл бұрын
This won’t work. You need to involve the floor system and the footing. Joist run parallel to the foundation wall and from an engineering stand point need wood blocking a minimum of 5’ back at the strap location.
@FamilyFriendlyDIY
@FamilyFriendlyDIY Жыл бұрын
Awesome. Thank you. Just what I was looking for!
@theimaginarygallery5935
@theimaginarygallery5935 Жыл бұрын
Who is going to check to make sure all of these codes are followed & if they are not, what are the consequences & who enforces them?
@nolanengineeringpllc2713
@nolanengineeringpllc2713 Жыл бұрын
We are an architecture and engineering firm that provides blueprints for both residential and commercial clients so we are well versed in building codes. Our products have been sold in all 50 states and Canada and have been accepted by code enforcement officials.
@Allegedly2right
@Allegedly2right Жыл бұрын
Product name is?
@nolanengineeringpllc2713
@nolanengineeringpllc2713 Жыл бұрын
Joist Repair Kit - available at nolanstructuralproducts.com/collections/joist-repair-kit
@Allegedly2right
@Allegedly2right Жыл бұрын
@@nolanengineeringpllc2713 Proper proper stuff we don’t get it in the 🇬🇧definitely 10/10
@jimc6694
@jimc6694 Жыл бұрын
I dont understand how this will keep the wall from bowing since the metal strips bend and can be cut so easily
@go-toolzreviews
@go-toolzreviews Жыл бұрын
Hey Mr Nolan do you have a email I'm a engineering technician from Trinidad and Tobago and I want to get some info
@Ashroyer86
@Ashroyer86 Жыл бұрын
Id want that repair strap min 1/4" thick how you show it going on. Thinner, I would put it on the face over the cracked area. Steel has similar strength orientation as lumber.
@rapturebound197
@rapturebound197 Жыл бұрын
Great idea.. great design.. super application.. love em'.. want to use them.. BUT wayyyy overpriced... $$$$ 👎
@oldmanpatriot1490
@oldmanpatriot1490 Жыл бұрын
This was very informative... I am not ashamed to admit I too thought it was tree roots.... Glad I didnt kill that tree
@jamesventura3689
@jamesventura3689 Жыл бұрын
Would these bring excessively notched joists in the middle to code then? Would they pass inspection in Kentucky?
@nolanengineeringpllc2713
@nolanengineeringpllc2713 Жыл бұрын
James, please send us a picture of your notched joists to [email protected] so our engineer can determine if our products will work for your situation.
@griffandrews3434
@griffandrews3434 Жыл бұрын
Liked and subbed!!! I think you will be interested in S M Z E U S.
@lenworthcampbell7514
@lenworthcampbell7514 Жыл бұрын
Interesting 🤔
@Scott-jv6qm
@Scott-jv6qm Жыл бұрын
Well, if you know where the toilet flange or shower drain is supposed to be, maybe move or box the the floor joist!