Пікірлер
@amornratrat
@amornratrat 13 күн бұрын
Thank you very much 😊
@amornratrat
@amornratrat 16 күн бұрын
Thanks ❤😅
@jameslittle2264
@jameslittle2264 16 күн бұрын
your welcom..
@amornratrat
@amornratrat 16 күн бұрын
@jameslittle2264 please if have Angilents LC MSMS .i would like to learn from video.
@jameslittle2264
@jameslittle2264 16 күн бұрын
@@amornratrat see littlemsandsailing.com/2024/10/using-agilent-masshunter-to-perform-nist-msms-search/
@neophoys
@neophoys 2 ай бұрын
Thank you for this video, Mr. Little! I really appreciate you giving us all access to your deep knowledge of Mass Spectrometry as learning it without a hands on mentor can be a daunting task.
@jameslittle2264
@jameslittle2264 2 ай бұрын
Glad it was helpful!
@MooreAnalytical
@MooreAnalytical 5 ай бұрын
Hello Mr. Little, I just recently found your videos and they are excellent. Do you have any recommendations for books and other reference to refer to regarding mass spectra interpretation?
@jameslittle2264
@jameslittle2264 4 ай бұрын
Fred McLafferty's book on interpretation is what i started with many years agoa
@laplynnchua683
@laplynnchua683 5 ай бұрын
Hi very good video. Thank you. I get a problem when I right click on spectrum to do a mass spectrum search using nist ms program . The nist pathway does not show up. I am unable to locate the nist ms directory. Can you suggest how I can resolve this ?
@jameslittle2264
@jameslittle2264 5 ай бұрын
Sounds like some problem when installing the NIST search program. Might uninstall all the NIST software and try again. Usually the NIST search software and AMDIS will be present at the same level in the NIST23 folder, e.g, NIST23/AMDIS/AMDIS_32.exe and NIST23/MSSearch/nistms.exe, NIST technical support is very good by contacting David Sparkman <[email protected]>
@laplynnchua683
@laplynnchua683 5 ай бұрын
Thank you so much for your reply. Will check that out.
@jameslittle2264
@jameslittle2264 5 ай бұрын
@@laplynnchua683 also remember than you must first run the deconvolution program before you are able to send a spectrum to manual nist search, always thought that was somewhat counterintuitive, but apparently not to the nist programmers..
@brianruddy8785
@brianruddy8785 6 ай бұрын
Thanks for the responses, James. Know where in the other videos that you detail the specific library search options for your hybrid search? Do you just choose all msms searches available?
@jameslittle2264
@jameslittle2264 6 ай бұрын
littlemsandsailing.com/2020/08/ms-master-class/ Part IV
@brianruddy8785
@brianruddy8785 6 ай бұрын
how do you paste in in peak lists? (sorry in advance if this is covered later than where I am)
@jameslittle2264
@jameslittle2264 6 ай бұрын
you use AMDIS to get spectra into the speclist for searching. Other programs from Agilent and Thermo will send their spectra to speclist for searching. The user can also add their spectra manually peak by peak in the librarian tab entering the basepeak as 100 or 1000 intensity and then all the other peaks the appropriate intensity relative to the base peak. Manually is not recommeded, very time consuming. AMDIS processes the files of many different instrument manufactures, you just have to know where the file is located and specify the correct file format in AMDIS. I also have a simpler course which includes free spectra and software that I developed for university students, littlemsandsailing.com/2023/08/university-laboratory-for-gcms-data-processing/ Good luck and fair winds!
@brianruddy8785
@brianruddy8785 6 ай бұрын
@@jameslittle2264 so there is no way to copy a peak/intensity list? What about using the MS interpreter program?
@jameslittle2264
@jameslittle2264 6 ай бұрын
nope, can create an msp file and import it, can see the MSP format in their manual or take one of their library spectra and export in MSP format. MSP contains some meta data such as name, MF, MW, but the main thing is for the msp file to tell the number of m/z pairs in the file which is then listing the m/z vs intensity files. Essentially AMDIS, Thermo, and Agilent create that MSP file for you when you send a spectrum to the NIST search from the these programs
@afifalaraib9159
@afifalaraib9159 6 ай бұрын
a question: how can I check the presence of certain compounds(from their MOL or SDF files) in my GCMS data in AMDIS? One solution that comes to my mind is to convert the structures in .msp format & then run through my GC MS data. But how can I achieve this ?
@jameslittle2264
@jameslittle2264 6 ай бұрын
the AMDIS manual shows you how to look for targeted comopunds if you make a library containing the species of interest, when AMDIS finds, will mark with a T, don't think I demonstrated that in any of my videos, but the AMDIS manual does that, a simpler way is to just plot ions of interest in the unknown spectrum that are somewhat unique and see their extracted ion chromatogram versus time in AMDIS
@afifalaraib9159
@afifalaraib9159 6 ай бұрын
​@@jameslittle2264 yes, you have mentioned in one of your videos about T mark against "targets" in your spectrum. I'm interested in knowing how I can add compounds of interest in a library if I DON'T have their spectra?. I have made my own library but it contains compounds whose spectra I already have from my GCMS data. There's this NIST Chemistry webbook where I can look at a spectrum of compounds of my choice, but it's not downloadable.
@jameslittle2264
@jameslittle2264 6 ай бұрын
@@afifalaraib9159 I have copies of the NIST and Wiley and other libraries, about 1.7 million EI spectra plus I get 14,000 each year from NIST for quality evaluation and also new ones from Wiley. Thus maybe at least buy the newest NIST and Wiley in NIST format and can save the spectrum of interest in MSP format and use add to AMDIS library for T (targeting) or as a minium plot extracted ion chromatograms in AMDIS to look for things of interest. If not exact spectrum in Wiley or NIST, can do similarity structure search to guess what your spectrum might look like and then plot the appropriate ion in AMDIS. Normally I search everything in the file of interest noting what is certain and use that information to refelect on possible identities of unknowns. Accurate mass and CI is very important for unknown identification. As you can see, an involved process and a variety of approaches including sample history involved in unknown identification.
@afifalaraib9159
@afifalaraib9159 6 ай бұрын
@@jameslittle2264 thank you very much for your insights. It helped a lot. And thank you for the videos.
@afifalaraib9159
@afifalaraib9159 6 ай бұрын
Thank you for this detailed video, i have a question tho: i have successfully created my library following these steps but when i try to open my spectra in NIST,I don't get any hits. How can i resolve this?
@jameslittle2264
@jameslittle2264 6 ай бұрын
You should be able to go to Search Tab and search to see all the spectra in your library to make sure they were created. Also would need to make sure your libraries are indexed under the tools tab. In particular, InChikey, Structure, hybrid search if doing hybrid searches. Then make sure under library search options, make sure your library is selected in both the spectrum and structure searches. Hope this helps.
@afifalaraib9159
@afifalaraib9159 6 ай бұрын
@@jameslittle2264 thank u for your help. One more question: under library search options, should I select RI (GC) option?
@jameslittle2264
@jameslittle2264 6 ай бұрын
only if you have RI data on your compound that you measured with an RI ladder (mix of hydrocarbon standards), separate section on doing that with AMDIS
@afifalaraib9159
@afifalaraib9159 6 ай бұрын
@@jameslittle2264 got it. I have added 3 libraries in Nist, one of my own & 2 are MONA libraries(GC & LC MS). I am not getting any hits of my spectra, even the ones which I added in my library (along with their structures). I have followed all the steps & guidelines that you mentioned
@afifalaraib9159
@afifalaraib9159 6 ай бұрын
@@jameslittle2264 thank u. one more question: i have successfully added 3 libraries in NIST, one of my own and two from MONA (GC and LC MS). But i am not getting any hits from them, even from the spectra that I have added (along with relevant structures) in my library. How can i resolve this?
@durmonov
@durmonov 7 ай бұрын
Thank you so much!
@jameslittle2264
@jameslittle2264 7 ай бұрын
your welcome
@renzoleeflang7872
@renzoleeflang7872 8 ай бұрын
Thank you! I am wondering if it is possible to calculate the isotope distribution for C13 labeling experiments and how to do this using MS Interpreter. I would want to know the number of molecules woth 1, 2 and 3 C13 carbons in my propane gas sample
@jameslittle2264
@jameslittle2264 8 ай бұрын
cannot do with MS interpreter unfortunately
@seeigecannon
@seeigecannon 8 ай бұрын
Thank you so much for this video. I am learning this on my own at work, so it has been a slow process, but this video showed me a lot of things I was unaware of in this software. Question: Is there a way to subtract a baseline/constant? One of my GC columns was contaminated with a silicone oil, so the output looked great with the exception of about 4 masses that were ever present. While that is fixed now (though the new column has fewer theoretical plates) my helium supply is contaminated with a bit of argon, and it would be nice to just ignore that line. Thanks again for the work you did for this presentation.
@jameslittle2264
@jameslittle2264 8 ай бұрын
AMDIS should remove all these peaks when you deconvolute in NIST software. In Wiley KnowItAll, MSExpert should also removed. Can do manual background subtract in AMDIS, but it is not trivial. In KnowItAll, ProcessIt has a very good manual background subtract. Hope this helps! Fair winds and following seas!
@neophoys
@neophoys 9 ай бұрын
Thank you very much for this informative webinar! I am learning heaps and am eager to implement these analysis techniques into my workflow.
@jameslittle2264
@jameslittle2264 9 ай бұрын
Your welcome. See my website for more MS information. littlemsandsailing.com/
@neophoys
@neophoys 9 ай бұрын
Thank you for this very informative video Mr. Little! I am currently teaching myself to analyze GC-MS data as there is nobody available to teach me. Your webinar series is an invaluable resource to that end!
@jameslittle2264
@jameslittle2264 9 ай бұрын
Good luck. See my website for other resources littlemsandsailing.com/ Also a simple NIST course with first link, or more detailed with second littlemsandsailing.com/2023/08/university-laboratory-for-gcms-data-processing/ littlemsandsailing.com/2020/08/ms-master-class/
@jameslittle2264
@jameslittle2264 6 ай бұрын
the best way is to import from AMDIS, or Agilent, or Thermo software. Can enter in librarian one peak at a time, or if you have such a list put it in NIST MSP format and import it into the NIST search program. The MSP format has fields such as MW, MF, etc, but most important is the number of mass/intensity peaks in the list. I think their format is included in the NIST maual or a few such files are supplied with the software.
@breakmeifyoucan
@breakmeifyoucan 11 ай бұрын
Thank you very much, the video is pretty much helpful.
@nguynnguyn7882
@nguynnguyn7882 11 ай бұрын
where can I download software, I don't find link
@jameslittle2264
@jameslittle2264 11 ай бұрын
version 3, buy, old version free, littlemsandsailing.com/2023/08/28/university-laboratory-for-gcms-data-processing/
@adamhoward2230
@adamhoward2230 Жыл бұрын
Great content from one of the world's best GCMS and MS Search experts!
@jameslittle2264
@jameslittle2264 Жыл бұрын
Quite a compliment from an expert such as you! Keep up all the great work in GCMS at Eastman.
@amornratrat
@amornratrat Жыл бұрын
Thank you so much 👍, I will subscribe forever.
@jameslittle2264
@jameslittle2264 Жыл бұрын
Hope you find it useful, developed for a local friend, decided to share with others.
@samstevenson5979
@samstevenson5979 Жыл бұрын
This will be a great adjunct to incorporate GC/MS methods in structure elucidation for my organic students. It's also a great for a foundation for studies in metabolomics and natural products. Thank you, James.
@jameslittle2264
@jameslittle2264 Жыл бұрын
hope it is useful, good for free software!
@2011carlie
@2011carlie Жыл бұрын
Do you use Mass Hunter(Qualitative)? If so, how about calibrating the alkane ladder and importing the RI for the unknown into NIST using Mass Hunter vs ADMIS?
@jameslittle2264
@jameslittle2264 Жыл бұрын
at one time used MassHunter, but no longer, I know masshunter can send spectra to NIST search, but don't know if RI is one of the fields they send. You would have to try then look in the library editor/edit then either the additional info or experimental data fields or see if they populate the correct RI field when sending to NIST search.
@LisaChen-n2u
@LisaChen-n2u 2 ай бұрын
kzbin.info/www/bejne/fZqQhIKAorJ9jK8
@PrasadaRaoKongalaprasadakongal
@PrasadaRaoKongalaprasadakongal Жыл бұрын
Thank you very much
@jameslittle2264
@jameslittle2264 Жыл бұрын
your welcom
@surendersehrawat3753
@surendersehrawat3753 Жыл бұрын
My another doubt is, NIST shows compounds like Formic acid, 2-ethylhexyl ester... so is it Formic acid only with some additional compound during derivatization or the whole is the main compound
@jameslittle2264
@jameslittle2264 Жыл бұрын
if 2-ethylhexyl ester, that is what it is, not the alcohol or free formic acid
@surendersehrawat3753
@surendersehrawat3753 Жыл бұрын
Hi Dr. James, I need to know about the already derivatized sample, most of the search results appear with TMS, so the main compound is before the tms
@jameslittle2264
@jameslittle2264 Жыл бұрын
you just have to take off the TMS to get structure of original compound
@SirShanova
@SirShanova Жыл бұрын
This rocks!
@jameslittle2264
@jameslittle2264 Жыл бұрын
thanks
@jameslittle2264
@jameslittle2264 Жыл бұрын
your most welcome
@Elementalistimo
@Elementalistimo Жыл бұрын
Thanks a lot for your videos
@jameslittle2264
@jameslittle2264 Жыл бұрын
your welcome
@kava2372
@kava2372 Жыл бұрын
P r o m o s m 😭
@muhammadumair1644
@muhammadumair1644 2 жыл бұрын
I have two results as of aqueous and methanolic extract of plant sample
@jameslittle2264
@jameslittle2264 2 жыл бұрын
no worries, just analyzed by gcms as derivatized forming TMS derivative or possibly underivatized
@muhammadumair1644
@muhammadumair1644 2 жыл бұрын
Can u describe a result of gcms for me as I cannot understand it
@jameslittle2264
@jameslittle2264 2 жыл бұрын
gcms is used to identify organic compounds in a mixture
@victoromondi6347
@victoromondi6347 2 жыл бұрын
Great presentation james
@jameslittle2264
@jameslittle2264 2 жыл бұрын
Thanks for the feedback
@vaheatoyan6875
@vaheatoyan6875 2 жыл бұрын
Hi and thanks for video, can u please tell how to fix the following problem. When I open NIST it says Nistern.dll is missing from your computer, if you know how to fix it please be kind and answer)
@jameslittle2264
@jameslittle2264 2 жыл бұрын
Don’t know besides reloading
@jameslittle2264
@jameslittle2264 8 ай бұрын
No you cannot do with MS interpreter
@Elementalistimo
@Elementalistimo 2 жыл бұрын
Thank you for video, it is very helpful
@jameslittle2264
@jameslittle2264 2 жыл бұрын
Glad it was helpful!
@selenophileselenophile7289
@selenophileselenophile7289 2 жыл бұрын
Hi James, I am working on LC-MS/MS for phenolic metabolites, is this library will be useful or you have any suggestion how to process MS/MS data through library. Thnaks
@jameslittle2264
@jameslittle2264 2 жыл бұрын
depends on which software one uses and which libraries are available, can try the NIST MSMS library which is the largest using the video course that I teach on MSMS spectra, wiley has MSMS library but much smaller and there is the MONA library. I don't know which would be the best for your app, would have to try, if use something like mass hunter, the software can import accurate mass data into the NIST hybrid search
@selenophileselenophile7289
@selenophileselenophile7289 2 жыл бұрын
@@jameslittle2264 hi james, I have MASS hunter. Can you share link from where I can't download MS/MS library.
@selenophileselenophile7289
@selenophileselenophile7289 2 жыл бұрын
@@jameslittle2264 I am using MS dial for MS/MS data analysis. If You will me to provide NIST MS/MS library, it will be grateful for me. Thanks for reply.
@jameslittle2264
@jameslittle2264 2 жыл бұрын
@@selenophileselenophile7289 in nist format drive.google.com/file/d/1yfuYVN62liLmj8JQiKi_25EPf4dmFyhX/view
@jameslittle2264
@jameslittle2264 2 жыл бұрын
look on my website, whole course on NIST and LCMS
@philipwenig7826
@philipwenig7826 2 жыл бұрын
Excellent!
@jameslittle2264
@jameslittle2264 2 жыл бұрын
Many thanks!
@jameslittle2264
@jameslittle2264 2 жыл бұрын
your welcom
@meganlouev
@meganlouev 3 жыл бұрын
Really useful video to get the hang of this software, thanks!
@jameslittle2264
@jameslittle2264 2 жыл бұрын
Glad it was helpful!
@jameslittle2264
@jameslittle2264 9 ай бұрын
glad it is helping, lots of things on my website related littlemsandsailing.com/
@joaoraulbelinatodesouza226
@joaoraulbelinatodesouza226 3 жыл бұрын
Thanks James for this very useful seminar.
@jameslittle2264
@jameslittle2264 3 жыл бұрын
your most welcome
@abeeral-sakkaf1914
@abeeral-sakkaf1914 3 жыл бұрын
Thank you so much, too useful. But need how can install it
@jameslittle2264
@jameslittle2264 2 жыл бұрын
look on NIST for free version to download or buy the library from a distributor and comes with install disk for software
@abeeral-sakkaf1914
@abeeral-sakkaf1914 3 жыл бұрын
Can you send me link for download this program free? Please
@jameslittle2264
@jameslittle2264 2 жыл бұрын
came with my version of NIST 20 library, so free in a sense because not charged for the search software
@jameslittle2264
@jameslittle2264 2 жыл бұрын
free download of software on nist website, but must pay for library
@wesp5
@wesp5 3 жыл бұрын
One small question: How come that you use MS Search 2.4 when the official versions are called 2.0f or 2.0g?
@jameslittle2264
@jameslittle2264 3 жыл бұрын
I am using the newest version of MS Search delivered with NIST20 library, some differences over the versions that you refer to
@amornratrat
@amornratrat 3 жыл бұрын
Thank you very much.
@jameslittle2264
@jameslittle2264 3 жыл бұрын
Thanks
@amornratrat
@amornratrat 3 жыл бұрын
Now I am using GC-MS-SPME develop method off-aroma in milk powder. Qualitative check RT and m/z from nist with mix standards aldehydes such as propanal ,butanal ,hexanal..... decanal . But I have problem propanal& butanal seems that mass not unique . These are not linearity. Do you have introduce to me?. I try concentrate 0.2-10 ppb.sorry my English is not very good.
@jameslittle2264
@jameslittle2264 3 жыл бұрын
propanal m/z 58 and butanal (m/z 72) do have different spectra, take a look in the nist library