Пікірлер
@nathanhua5605
@nathanhua5605 3 ай бұрын
If I want to set up a third remote do I need the first 2 remotes in the vicinity?
@DitecTube
@DitecTube 3 ай бұрын
Hello @nathanhua5605! Absolutely NOT, you can memorize the remotes at any time and without the need to have the transmitters already memorized with you. Go to the RO>enter>SR>enter> menu and when SR flashes on the display, you can memorize the new remote (In the video you can watch the memorization procedure from minute 04:50 to minute 05:30).
@romansanchezcabrera
@romansanchezcabrera 5 ай бұрын
Hello, I have the same problem. 2 new ZEN2 remotes flash 5 times and will not factory reset. I have also tried it by enabling and disabling the AES. Any recomendation ? Thanks
@DitecTube
@DitecTube 5 ай бұрын
Hello @romansanchezcabrera, after you remove the battery, you need to be sure to press both push-buttons SIMULTANEOUSLY. Keeping both push-buttons pressed, you must reinsert the battery and wait for the LED to flash 10 (TEN) times. Only after the tenth flash you can release the two push-buttons on the transmitter, which will have returned to the "out of factory" values.
@romansanchezcabrera
@romansanchezcabrera 5 ай бұрын
@@DitecTube Nothing, I do it exactly like this but it takes a few seconds for the LED to flash and it only flashes 5 times. I don't understand why. I have tried every possible way.
@DitecTube
@DitecTube 5 ай бұрын
@romansanchezcabrera, if the LED flashes 5 times it It could mean that AES-128 encryption has been enabled instead of factory reset and this would mean that only one of the two buttons has been pressed (maybe the other is broken...). This can be easily verified, once the procedure is finished, by pressing the buttons one at a time and looking at the LED: if the LED transmits with a fixed light it means that it is rolling-code; if the LED transmits fast flashing light, it means it is encrypted. Anyway, what is the reason why you need to perform Factory Reset?
@DitecTube
@DitecTube 5 ай бұрын
@romansanchezcabrera, sorry but from the P15 version the ZEN SW has been modified and after the Factory Reset the LED flashes 5 slowly, while after the encryption procedure the LED flashes 5 fast. This means that your ZEN2 has successfully returned to factory settings.
@romansanchezcabrera
@romansanchezcabrera 5 ай бұрын
Thank you very much for your help. They seem to be working correctly now by unpairing them from the door motor and pairing them up again.
@ily_000
@ily_000 8 ай бұрын
Dear sir can you send me HD quality video I can't see anything it's low quality
@DitecTube
@DitecTube 8 ай бұрын
Sorry we have only this video. Please check page 29 or 33 (left side) of the installation manual and: IF YOU HAVE TO INSTALL BOTH DAB905ESE AND DAB905ESA cards: 1. Insert LONG-PIN into multi-hole connector of DAB905ESE card, 2. Insert LONG-PIN base (with DAB905ESE card inserted) into multi-hole connector of DAB905CU (main control unit), 3. Screw 2x 5mm NUT DRIVER and 1x TORX T10 screw to keep DAB905ESE card in place, 4. Insert DAB905ESA card in the pins of the LONG PIN, 5. Screw 2x TORX T10 screws to keep DAB905ESA card in place. IF YOU HAVE TO INSTALL ONLY DAB905ESE OR DAB905ESA single card: 1. Insert SHORT-PIN into multi-hole connector of the card (DAB905ESE or DAB905ESA), 2. Insert SHORT-PIN base (with the ESE or ESA card inserted) into multi-hole connector of DAB905CU (main control unit), 3. Screw 3x TORX T10 screws to keep DAB905ESA card in place.
@TheChamji
@TheChamji 9 ай бұрын
This does not work with one of my works remotes. Continuing to press the top and bottom button after taking out/returning battery causes light to flash 5 times. Remote refuses to duplicate gates code while other ones were fine.
@DitecTube
@DitecTube 9 ай бұрын
Hello @TheChamji - The 5 flashes after inserting the battery could mean that AES128 encryption has been enabled, however this occurs by pressing only one of the two buttons - plesa watch kzbin.info/www/bejne/iWibaKhmbqd2a7M&pp=gAQBiAQB maybe one of the buttons of your works remote is faulty...
@ileanakuakini5200
@ileanakuakini5200 10 ай бұрын
💥 "promosm"
@cashwallwork
@cashwallwork 11 ай бұрын
Will this selector work on the Ditec QE94 processor?
@DitecTube
@DitecTube 11 ай бұрын
Hello @cashwallwork, YES - COM-E selector can work with QE94 control panel. Connections: 0 (COME) to 0 (QE94) / 1 (COME) to 1 (QE94) / 21 (COME) to 21 (DIR) / 22 (COME) to 22 (DIR). Contact 1-8 (QE94) is independent from the selector, it will be necessary to make a jumper if it is not used, contact 1-9 (QE94) is to be considered in series to the STOP set by the selector, so it will be necessary to make a jumper if it is not used.
@khalidjadenadonza9143
@khalidjadenadonza9143 Жыл бұрын
We have a door here ditec DAS 107 PLUS MODEL.. the opening is slow even the parameter 00 set to 60..how to troubleshoot?
@DitecTube
@DitecTube Жыл бұрын
Hi @khalidjadenadonza9143, please check that contacts 1-2 and 1-4 are bridged (closed).
@haerbgroub5794
@haerbgroub5794 Жыл бұрын
Good
@nurettinkabak2913
@nurettinkabak2913 Жыл бұрын
Ion 6 model 30 and 5 inputs do not open and close the door anymore what should I do and which model should I buy a spare remote for this product thanks
@DitecTube
@DitecTube Жыл бұрын
Hi @nurettinkabak2913, please check that the accessory (push-button, key-switch ecc.) connected to 30 and 5 is not short-circuited: you can remove the wire from terminal 5 and then re-connect it again to see if the door open and close. You can also try with the simultaneous pressing of UP Arrow and ENTER keys for opening operation and simultaneous pressing of DOWN Arrow and ENTER keys for closing operation. Check for any error message shown on display. For the spare remote you should look for the same model you are actually using (ZEN2 or ZEN4 I guess).
@MikeWatts-w5o
@MikeWatts-w5o Жыл бұрын
Hi, I have changed the batteries in our Ditec EL 16 system and now the doors are not opening or closing. Tried the panel reset but still not working. Could you help please?
@DitecTube
@DitecTube Жыл бұрын
Hi, if the EL16 is powered (PWR Green Led ON), please check if there are 24 VDC between terminals 0 and 1, then check the position of the COM-E operations selector and that the terminal 9 is bridged with terminal 1. Check that the jumper [J] is correctly inserted into DIR card connector on the left (first jumper on the top should be closed). Disconnect the COM-E function selector from EL16/DIR card and perform a SETTING RESET by keeping the OPEN button pressed (for 4 s), until the IN LED starts to flash. To confirm the operation, press the OPEN button again for 2 seconds within 4 seconds, at the end the door should work in two-way mode. Then reconnect COM-E and check the operations. If the EL16 is not powered (PWR Green Led OFF), please check main power line, the power supply unit fuse and the power supply unit output (approx. 27 VAC).
@rameshbabubabu9766
@rameshbabubabu9766 Жыл бұрын
Not open
@DitecTube
@DitecTube Жыл бұрын
Hello @rameshbabubabu - in order to help you, we would kindly need a few more details. Thank you
@Micro-YTgaming
@Micro-YTgaming Жыл бұрын
I have a question . What does it mean when you put in the correct code and the keypad light is red and green and not opening the gate anymore ?
@DitecTube
@DitecTube Жыл бұрын
Hello Bubba K! The red and green combination may occurs in case of mistake during replacement of the factory code with a new one, but usually it never appears. Try to RESET the keypad to Factory Default condition by pressing simultaneously 7 and 9 keys together for 10 sec (if the operation is successful, the RED LED flashes for 10 sec). Then verify that the factory codes (CH1=3333, CH2=4444, CH3= 6666, CH4= 7777) are working, then enable the Code Change function by pressing key 5 for 3 sec (if the operation is successful, the RED LED flashes for 3 sec) and finally try to replace the factory code with a new one. Good luck!
@Micro-YTgaming
@Micro-YTgaming Жыл бұрын
@@DitecTube Thank you for the reply . I tried to reset it using your instructions and it will not reset . Anything else I could try next to buying another keypad ?
@DitecTube
@DitecTube Жыл бұрын
@Bubba K - Sorry I skipped a step in the procedure... the correct sequence to RESET the keypad to Factory Default condition is: 1) - digit the config code 676158 2) - press the F function key for 3 sec -> the red Led light ON 3) - press simultaneously 7 and 9 keys together for 10 sec (if the operation is successful, the RED LED flashes for 10 sec) 4) - wait 30 sec to let the keypad exit from configuration mode You can download the technical manual here: www.ditecautomations.com/global/it/content-fragments/products/gate-automation-garage-and-industrial-doors-automation/accessories/controls/radio-digital-combination-keypad/assets/downloads/technical-manual/Ditec%20AXK4%20Manuale%20tecnico%20(multilingue).pdf
@albaharh
@albaharh Жыл бұрын
Thank you soo much,you’ve helped me to get this sorted after I😅 up lol cheers mate
@martinrssg1
@martinrssg1 Жыл бұрын
Buenas noches amigo una consulta tengo el modelo nes1000 y arroja error IO
@DitecTube
@DitecTube Жыл бұрын
Hola Martin, el error "IO" significa que el cuadro eléctrico detecta que el circuito de alimentación del motor está interrumpido debido a que el MOSFET (el componente electrónico que acciona el motor) no puede cerrar el circuito y por lo tanto alimentar el motor. Puede tratarse de una falsa alarma, que normalmente se soluciona realizando un RESET, es decir, desconectando el conector del motor, la red eléctrica y las baterías (si las hay) y volviendo a conectarlo todo, pero también puede ser que realmente haya fallado el MOSFET (Alarma "IO" persistente tras RESET) por sobretensión y en este caso será necesario sustituir la placa electrónica CS12M (el código de la placa electrónica de repuesto es NC6CS12M - contacta con tu instalador/distribuidor de confianza). Que tengas un lindo día!
@yeinstoro9929
@yeinstoro9929 2 жыл бұрын
Solo con un pulsador para abrir y cerrar es que tengo un cliente que no quiere sensores
@DitecTube
@DitecTube 2 жыл бұрын
Hola Yeins Toro, gracias por tu pregunta. Sí, por supuesto, no hay problema: puede usar uno o más botones (por ejemplo, uno interior y otro exterior) para abrir, luego la puerta se cerrará con cierre automático. La apertura de la puerta también se puede accionar con un empujón en la hoja, por lo tanto sin ningún dispositivo de mando externo. En cualquier caso, se recomienda la instalación de un selector de funciones para gestionar la habilitación y exclusión de los mandos de apertura, cualquiera que sea. Para cualquier otra información o contactar con nosotros visita nuestra web www.ditecautomations.com/es. Que tengas un buen día!
@yeinstoro9929
@yeinstoro9929 2 жыл бұрын
Una pregunta esas puertas se pueden usar sin el sensor
@louispj6078
@louispj6078 2 жыл бұрын
Good
@DitecTube
@DitecTube 2 жыл бұрын
Hello Louis P J, thank you for your comment.
@shakirafathima1337
@shakirafathima1337 3 жыл бұрын
Hi good products in automation for commercial, residential and industrial professional design services I can improve retail sales in Dubai if distributors are available kindly provide me details thanks for your media support best regards Arabian link doors sharjah
@DitecTube
@DitecTube 3 жыл бұрын
Hi, thank you for your comment. Please contact us here: www.ditecautomations.com/en/contacts/customer-service/ . Best regards
@shakirafathima1337
@shakirafathima1337 3 жыл бұрын
Good to learn very well explanations hope to be viwe like this in swing door operator also best wish to the media team from Arabian link doors sharjah
@DitecTube
@DitecTube 3 жыл бұрын
Hi, thank you for your comment. On our channel you can find also the video trainings for Swing door operators: kzbin.info/aero/PLuOFfmzjkgA0uV9NfxVidqj_dNmhXsprP kzbin.info/aero/PLuOFfmzjkgA0RFxBDKdjk4vRIJIM5CkE3 kzbin.info/aero/PLuOFfmzjkgA23RYrekgHRHPI3I4KehdFy Best regards
@yeinstoro9929
@yeinstoro9929 2 жыл бұрын
Instale una puerta ditec das 107 plus pero no la quieren con sensores, la quieren con un pulsador botón de accionamiento quiero saber si se puede
@serenaottanelli5061
@serenaottanelli5061 3 жыл бұрын
this remote control model have Rolling code?
@DitecTube
@DitecTube 3 жыл бұрын
Hi Serena, NO this models (ZEN2C / ZEN4C) work with Fixed Code or "Dip Switch" code only at 433 MHz frequency. The references for ROLLING CODE are: [433 MHz] = ZEN2, ZEN4, ZEN2W, ZEN4W, ZEN2G, ZEN2B, ZEN2Y, ZEN2R, ZEN2MT, ZEN4MT. [868 MHz] = ZENP2, ZENP4, ZENP2MT, ZENP4MT. All the Rolling code models can also be set in AES-128 Encrypted mode or in PROTECTED mode. Best regards
@gianluigiimpoliti6425
@gianluigiimpoliti6425 3 жыл бұрын
Per me gli svedesi non sanno il significato della parola automatica!!!!!! Come era piu' comoda la cara vecchia wel m
@elianksilva7008
@elianksilva7008 3 жыл бұрын
PODES ABRIR ATRAVEZ DO TELEMOVEL ?
@DitecTube
@DitecTube 3 жыл бұрын
Sim, o DAB105 pode ser conectado ao nosso sistema DITEC SMART CONNECT, útil para gerenciar qualquer automação via Smartphone: www.ditecautomations.com/pt-PT/produtos/automatismos-para-portoes-portas-de-garagem-e-portas-industriais/conectividade/entrematic-smart-connect/
@claudiosangaletti42
@claudiosangaletti42 4 жыл бұрын
buongiorno
@didaldaportoesautomatismos7431
@didaldaportoesautomatismos7431 5 жыл бұрын
DIDA,LDADISTRIBUIDOR OFICIAL DITEC ENTREMATIC EM BRAGA WWW.DIDA4720.COM