If I replace both checks 1 and 2, the top is screwed on tight, there are no leaks, and it was tested properly. Why would both checks still fail? I am completely lost.
@DancnWitDethКүн бұрын
I'm referring to a 2 inch 007. Both checks fail when I test it
@deebo641316 күн бұрын
WHAT THE TOOL CALLED HOMIE????
@MrSportkatАй бұрын
Y’all did a great job!! I couldn’t stop smiling! Merry Christmas 🎄 Adam Miller’s Backflow Solutions
@deankirkner5307Ай бұрын
Always so funny! Keep ‘em coming!🎄🎄🎄
@lindablack5587Ай бұрын
That was too funny! I think they get better and better every year! Happy Holidays and Merry Christmas!!
@_backflowjoeАй бұрын
Your video gave me a big chuckle, now I have to replace my buckle. Merry Christmas to all at American Backflow Products Company & warmest wishes this holiday season. Let's have a great 2025. Sincerely, backflowjoe
@ADZ.Ай бұрын
This was AWESOME!
@samwatson8429Ай бұрын
Excellent video !!!
@jackhayes1051Ай бұрын
I ain't drunk enough to keep watching this, and I'm in Louisiana, maybe once I got a shot or two in me, I'll continue
@yucasolaАй бұрын
Another great one! Merry Christmas from your fans at Padest Inc
@pedrocortez16832 ай бұрын
Thanks
@ChrisReitzel2 ай бұрын
I can't get either of the clips to pull out. Im scrapping this 8"unit so I will cut the edges with a torch
@brianrafferty18972 ай бұрын
i Just installed a 1inch watts LF009 backflow and it spits water from vent when the water pressure drops from 60psi to 20psi, then the booster pump kicks on and raises the presure back up to 60-70 with in a 1-2 second time frame. any ideas what could cause the quick spurt of water from vent in that small time frame?
@AmericanBackflowProducts2 ай бұрын
Brian, sounds like you are seeing the effects of pressure fluctuations. When the backflow senses that quick drop in pressure the relief valve will open temporarily to discharge. Once the pressure stabilizes the relief valve will close. This is the way an RP is set up to work so your device is working great.
@louiswilk8392 ай бұрын
Great video. Thank you
@jclbuxfan3 ай бұрын
I can’t get either one of my check valves to pull out WTF
@MrFernandes853 ай бұрын
Thank you!
@KalHassan-c6v4 ай бұрын
Thanks!
@JohnnyDominoRican5 ай бұрын
Dumb question can I use cooper anti seize on the valve steam for lubricantion on old valves ? I work at a oil refinery I’ve used it before and it helps on valves that are hard to spin
@kenm91706 ай бұрын
I test and repair hundreds of Backflow prevention devices annually, and I always use a smear of food-safe lubricant on all o rings upon reassembly of any device.
@Superguapo1007 ай бұрын
This particular model seems to fail a lot , even after repairs, have replace a few and next year some fail again… a guy from a different com also mention having issues with it .
@testtest6487 ай бұрын
I love that American Backflow is the only company that doesn't say "if you need to, flip the gasket and reinstall as a temporary fix until a new gasket can be found"
@josephballance23197 ай бұрын
Great video. Need help on why the relief valve would leak water. Found a rock in spring area. Cleaned the 860. Tia
@AmericanBackflowProducts7 ай бұрын
Joseph debris could cause your relief valve to leak or drip. Be sure to check the #1 and #2 check for debris as well. It is possible that the debris has damaged the parts which would mean you need to replace the parts. You can call us at 800 575-9618 for more technical help or to discuss replacement part needs. Thanks!
@TheBuddyLama8 ай бұрын
The two main check valve springs are different gauges. Which goes where? No videos ever say.
@dlchill8 ай бұрын
The stronger spring will go in the #1 check valve which is the check that is upstream. The weaker spring goes in the #2 check (downstream) check.
@gregfiggy98 ай бұрын
I have one with a constant stream coming from the relief, I’ve replaced the parts and still have the same problem. Any idea what would cause this issue?
@jonathanduncan64268 ай бұрын
Thank you for the video. Very helpful to see. I used a Relief Valve repair kit. After I installed the diaphragm and cover, I opened the ball valve from the water main. Water started shooting out from the sides of the Relief Valve where the diaphragm is. I have replaced Relief Valves in the past and I have never seen this behavior. I thought perhaps I did not tighten the bolts enough, so I tightened the more, the spray lessened slightly. I ran one of the sprinkler stations to get water flowing through the backflow assembly, the spray did stop briefly, but when I stopped the water flow the spray continued. Have you see water shoot out from the Relief Valve cover plate before? I am not sure how to proceed.
@jonathanduncan64268 ай бұрын
Well, I found this video that seems to have answered my question. kzbin.info/www/bejne/epfKXnqViq6NlcUsi=cxXm_RHWe2QKWp0M&t=275
@arturomonreal74328 ай бұрын
2" watts 009 , replaced all the rubers and still dumps every time I turn the water On , why , any help will be appreciated.!? Thanks I'm advance
@AmericanBackflowProducts8 ай бұрын
Thank you for reaching out. It could be a few different reasons the device is dumping. Please contact us and ask for our tech team so we can try and troubleshoot for you. Our number is 800 575-9618
@ChromeCalion9 ай бұрын
Now show us a video with 150 pounds of water on the valve while replacing the packings
@krakhare71119 ай бұрын
Ah Watts/Ames, whoever the hell currently owns you: your engineers must have graduated at the depths of their classes. I sincerely hope they spend the rest of their careers flipping burgers or dumping fryer oil for producing such a horrible device. Truth be told, no backflow preventer is easy to service; however, this is arguably the worst. Whenever customers approach me as to the best device to install, I will continue to trash talk your products and berate your staff. G.F.Y.’s
@makaulyleon72679 ай бұрын
Name of tool?
@hustletown201009 ай бұрын
Backseating has never worked for me the past 10 years
@DDunc10207 ай бұрын
Same here
@OD91MJ9 ай бұрын
Thank you. Saved me 300-1000 bucks finding this! I was going to just buy the whole backflow. The prices on these vary wildly.
@elkskiutah82049 ай бұрын
it would be nice if the demo repair unit looks like the ones us guys work on after 25 years in service... plus you didn't say to check the relief plate for flatness... should have been a 6 screw design.
@elkskiutah82049 ай бұрын
you damaged the relief valve stem removing that small o-ring... use a plastic pick.
@TheGardista10 ай бұрын
💪🏼
@RobieBrantley10 ай бұрын
I can't get the check valve assembly, or modules, to come out no matter how much I rock them, or how hard I pull. We have real hard water here. I was thinking that I could pour a muratic acid/water mix into the holes and let them sit for a few minutes like cleaning out my salt cell on my pool. Any other ideas?
@AmericanBackflowProducts9 ай бұрын
Robie, sounds like the scale from the hard water is locking those check in place. You need to be careful with anything that you add into the water system. You will need to make sure that it is safe and acceptable to use in a potable water system.
@cvltzilla9 ай бұрын
pouring acid into an rpz is bananas! 😂
@40hrplusservicetech11 ай бұрын
My favorite part is when he sticks the #2 check out past the flange knowing that’s not possible. This valve design is a joke , send the engineer back to his failed career as an Uber automotive enginerd.
@plumberjim492611 ай бұрын
It’s doesn’t tell you how to know if it is the relief valve
@AmericanBackflowProducts11 ай бұрын
Jim, what can we help you with on the relief valve of the 009?
@wallacefarrah675711 ай бұрын
How do I know which is shutoff number 1 or 2
@matthewracki801111 ай бұрын
Shut off number 1 will have a tapped ball valve (test cock on it) and the shut off number 2 will be non tapped.
@jeremybarnes15407 ай бұрын
#1 is on the inlet side. #2 is on the discharge side
@tapeman2000 Жыл бұрын
Yeah, i worked with a plumber who had a specialized ticket for it. I was trying to explain it to others, and it's hard.
@jbyers3005 Жыл бұрын
Great video
@aaronhayes4635 Жыл бұрын
Perfectly done ✅
@Thomasz126 Жыл бұрын
Hi the bottom seal is not reaching the relief valve seed on the bottom. Any advice? Water comes out from the bottom once I turn it on
@AmericanBackflowProducts Жыл бұрын
Thomasz, there are a few things that could cause that. It could be debris, sensing line issue or relief valve parts that need to be replaced. Please feel free to reach out to our tech team at 800 575-9618, we would be happy to help.
@Backflowandbeyond Жыл бұрын
You guys are Crazy, Looks like a great work environment. Thanks for the laughs. Glenn Pourteau, Bayou City Backflow & Plumbing.
@nondazwald Жыл бұрын
Oh man, thanks for making my day! Nonda Zwald Tillamook, OR :-)
@emilycallaghan5644 Жыл бұрын
OMG I wanna work with you guys it looks like you have so much fun on the job!!!!!
@yucasola Жыл бұрын
Thanks for the laughs. Padest Inc.
@deankirkner5307 Жыл бұрын
Your crew always posts the funniest videos !!!!😂😂😂😂~
@MikeBresler Жыл бұрын
What a joke having to site through commercials when I'm trying to get a job done. Shame on Febco for using KZbin.