Пікірлер
@antonzol
@antonzol Ай бұрын
Hi! Thanks for this video. Thinking about buying 8719ES have it power sweep mode?
@azadehghasemi3690
@azadehghasemi3690 Жыл бұрын
Can we leave the port open for Open calibration when we are performing SOLT calibration?
@Networkengie
@Networkengie 2 жыл бұрын
You mentioned about not threading in the calibration standards into your test leads as opposed to threading in the female side as a tip and you'd explain why later but you forgot to explain this. Is this because you could damage your calibration standards kit? I've heard of this a few times from others online but never understood why.
@idan_w
@idan_w 2 жыл бұрын
it could be a good idea to use it only with silicone mat when you doing any reflow or soldering because using wood could be a fire hazard also a good idea: find one of those thick aluminum tin foils or a disposable cheap aluminium oven tray you can buy at the supermarket and use it to cover the wood surface, that could add a little bit extra safety from fire risks
@remontlive
@remontlive 3 жыл бұрын
Thank you for special video about VNA
@joe10117
@joe10117 3 жыл бұрын
sorry theese filters do not work tried two it s ashared RF signal issue not cell towers not 5 6 G
@shayakbhattacharyya2160
@shayakbhattacharyya2160 3 жыл бұрын
Hello. You forgot to mention why the male was screwed onto the female SME and not the opposite? Would be a big help if you could clarify that
@ericabarrera7659
@ericabarrera7659 4 жыл бұрын
U stole my user
@user-xlario
@user-xlario 4 жыл бұрын
Thanks for this video! I'm not an expert on RF at all, but love it and I'm curious: why are these small squares in two rows near the output of the switch? An why the is a single strip of these squares near the left input but not on the right? I guess them are to adapt impedances, but I've not found yet a book that explains it.
@peterphanh203
@peterphanh203 5 жыл бұрын
I have a problem with my 2-1 Log Mag being to high of a dB @18GHz and it's reading at -40dB. any ideas? i think my setting is not set right. do you have a email?
@jaseclark9916
@jaseclark9916 3 жыл бұрын
dont know if you guys gives a shit but if you are stoned like me during the covid times then you can watch all of the latest series on instaflixxer. Been streaming with my girlfriend during the lockdown xD
@jerichokayson9509
@jerichokayson9509 3 жыл бұрын
@Jase Clark yea, been watching on instaflixxer for months myself =)
@ZL1CVD
@ZL1CVD 5 жыл бұрын
Some good explanations by why do you not clearly show what port you are plugging the short/open/load into?
@rfstuff5205
@rfstuff5205 5 жыл бұрын
Chris - Thank you for your question. In this video I am connecting the open/short/load to port 1 of the network analyzer (which is the leftmost port). This way, when that part of the calibration is complete the analyzer "knows" what each of these standards are and can calibrate based on them. In the calibration we're showing the analyzer a predictable open load, a short circuit, and a 50 ohm "good" match. Once we attach the device under test (DUT) it will be able to accurately measure how well (or how badly) the DUT reacts to the input stimulus across the frequency band we're calibrating with. Let's say that the device is well matched from 50 Mhz - 1.5 GHz, and is not well matched in other frequencies. We will then see a "good" match in that band (example: < -15 dB S11) and a "bad" match (example: > 4 dB S11) in those areas. I defined "good" and "bad" in quotes because those good and bad values all depend on what you are measuring. I hope this answers your question - I welcome any additional requests to explain/clarify in the comments if others have similar questions. Thanks again.
@roylt21
@roylt21 6 жыл бұрын
where are the rest of the videos you were talking about? Very interested in those, thanks
@muhammadiftikhar1206
@muhammadiftikhar1206 6 жыл бұрын
Thanks dear very iseful
@slumdogskillionaire923
@slumdogskillionaire923 6 жыл бұрын
1:40 OSL 3:55 Through 5:10 Display 6:20 StartStopFreq 6:36 Marker 7:10 Active Channel Button 7:45 CalInputReflChannel 11:00 CalOutputTransChannel
@slumdogskillionaire923
@slumdogskillionaire923 6 жыл бұрын
you are a genius, thank god you made that useful video!! I need it for university purposes because my proffesor does not want to help me with it!! Thank you, again!!!
@enochmarco448
@enochmarco448 3 жыл бұрын
Dont know if you guys gives a damn but if you guys are stoned like me during the covid times you can watch all the new series on instaflixxer. I've been binge watching with my girlfriend lately :)
@marceljaxson3481
@marceljaxson3481 3 жыл бұрын
@Enoch Marco yea, I've been using instaflixxer for years myself :D
@karsynkylo5002
@karsynkylo5002 3 жыл бұрын
@Enoch Marco definitely, I have been watching on InstaFlixxer for since november myself =)
@talclipse
@talclipse 6 жыл бұрын
A better option is to get a mic boom arm,or like i used a desk lamp arm(exactly the samething).i also used one of those cell phone dash mounts with the flexible arms and modified the end with a CCTV camera wallmount so it will screw right into the 201..
@sinosplastic
@sinosplastic 6 жыл бұрын
Hi, can show us some pictures,m?? Thanks
@lowearthorbit-delio
@lowearthorbit-delio 6 жыл бұрын
thanks for the presentation
@ElettronicaRiparo
@ElettronicaRiparo 6 жыл бұрын
kzbin.info/www/bejne/h4HEY6ZjndGWn9E
@slavapinchuk4829
@slavapinchuk4829 6 жыл бұрын
When will be the next video`s ? Thank you for this one!!!
@rfstuff5205
@rfstuff5205 6 жыл бұрын
Slava - much appreciate the feedback - this weekend I will post a follow on to this going over a simple passive device measurement (RF filter) and will work to put new content up every 1-2 weeks thereafter. Thanks again.
@mbaker335
@mbaker335 7 жыл бұрын
I am wondering why you are trying to clean up the pads with dry wick. A god dollop of liquid flux and the whole process takes seconds. You need liquid flux to get wick to work at all. It got quite painful to watch.
@rfstuff5205
@rfstuff5205 7 жыл бұрын
I’m sorry for the pain that this video you voluntarily watched has caused you. I agree that using additional liquid flux would be a good way to quickly clean and prepare the area. I’ll try that sometime. However, solder wick is impregnated with rosin-based flux, so saying that you “need to add flux for it to work at all” is not accurate.
@doanhpg
@doanhpg 7 жыл бұрын
hi, thank for sharing this useful video. i have some questions but i don't know if you could leave your email here to more easily contact .
@rfstuff5205
@rfstuff5205 7 жыл бұрын
Please post any questions you have in the comments. It may help others that have similar questions.
@doanhpg
@doanhpg 7 жыл бұрын
thank, sir. so what is the difference between the calibration from end user (e.g SOLT) and that from manufacturer's service
@rfstuff5205
@rfstuff5205 7 жыл бұрын
A very brief explanation: When a piece of equipment is calibrated by the manufacturer (or a cal company after initial calibration has expired), the equipment's stand-alone performance is verified, i.e. they make sure that the equipment is correctly performing and reporting accurate measurements. Typically, the reference points for these measurements during calibration are the connection ports of the equipment. The purpose of a user calibration is to remove any of the losses or measurement differences from other components connected to the device under test. For example, if you are measuring a filter, it's impossible to connect it directly VNA ports without using test cables, RF connector adapters, and other components in between the filter and measurement ports of the VNA. If you measured the filter without re-calibrating the test setup (with any cables and adapters used during testing), you would not be measuring the filter 's VSWR and insertion loss. You would be measuring the VSWR and insertion loss of the filter, the test cables, and any adapters you are using . That would not be an accurate measurement of the filter. The purpose of the user calibration is to compensate for the insertion loss and VSWR effects of all components you've set up between the device under test and the VNA, in order to get an accurate measurement of only the device being tested.
@doanhpg
@doanhpg 7 жыл бұрын
thank you, i would like to talk about the manufacturer's calibration. i know that there are many tests in each calibration, for each equipment (e.g VNA). so how do we establish these tests ?