Microinverters are sold to suckers. They clip the output of a 430 Watt panel to 290 Watts. If a string inverter has a wide MPPT voltage range like 60 to 480 volts, you can shade panels in the string and not lose the power from the others so long as the unshaded panels produce more than 60 volts. Micro inverters are a waste of $175 per panel. The sales guy loves them as they double the profit. Multi input string inverters are optimal. That's why the Tesla Powerwall 3 has six MPPT inputs. You can have six segments in the array and never have to climb on the roof to replace a failed microinverter.
@DontHaveTime5233 күн бұрын
That’s not trumps boy Elon says kzbin.info/www/bejne/noqraWhnec-AsJYsi=11fiZ8o5H1QCp2te
@wotanmituns335 күн бұрын
I've had this question on my mind for so long. And this is one the most comprehensive explanations I've come across so far. I really appreciate it!
@greecemobile761010 күн бұрын
What about the Ledvance inverters?
@greecemobile761010 күн бұрын
Victron Energy has good algorithm as string inverter for the shade or not?
@Nerdificationing11 күн бұрын
This is cringe. It's like an informercial. Most brands include a platform now. So Solar Analytics is redundant
@pwil701612 күн бұрын
Incredible work! I know a few people who have built great scalable businesses off the back of McDonaldsing :) Absolutely impressive, and the system you installed for me continues to go strong and always happy to recommend you!
@emmett306716 күн бұрын
Í guess Jake will be handing back the Enphase Award? What happened to the "safety" claims about DC not running through the roof?
@peterpanousis845817 күн бұрын
2 PW3’s with 2-inbuilt inverters. Is the second inverter utilised or is it redundant?
@philbowden637117 күн бұрын
What happened to the claim of "never installing DC string inverter systems"? 🤔
@ja802017 күн бұрын
Looks like Tesla can convert Jake too. Just wondering if that string system has all the flaws PSC evangelised about last year. Micro anyone??
@lupofiasc017 күн бұрын
Switchboard stated inverter in garage? What was the setup? 2 powerwall 3s setup as battery only?
@stephenbrickwood160217 күн бұрын
So no Enphase microinverters, 19 panels DC to batteries inverter. DC 600volts through the roof attic space and 600volts DC down inside the wall cavity. No rooftop fires, which is good. 😊😊
@stephenbrickwood160217 күн бұрын
people do not understand that the grid itself has a large cost to the customer. That is seen in my 5cents kWh feedin and 50cents kWh supply. But if all your energy comes off your roof and you stop gas heating etc, and petroleum purchases and grid supply electricity usage then the benefits to the customers just gets better. Grid owners are terrified of this. The suggestion that the grid may have to turn off rooftop PV with higher feedin causing grid destabilisation is a worry that customers may not turn the grid back on. Just leave the grid turned off until the customer needs a little more to top off the home battery now and again. As the grid cost itself are fixed, costs will need to be shared with fewer customers. 4million rooftop PV today, EVs being charged from home, v2g Australian Standards are being developed. More and bigger rooftop PV being installed. 10, 13, 17kW systems. People are trading in their old EVs for newer ones. The v2g features will stimulate more trade-ins. Selfplug-in selfparking will add to the v2g. When 20million 6.6kW rooftop PV then the customers will generate 660gWh. This is more than the fossil fueled 600gWh daily maximum possible. Actually, the avg demand is only 400gWh. I bet the grid owners will do a deal with rooftop PV customers and sign up heavy industrial customers moving away from fossil fuels. Same grid, more customers, less central generation, less distant renewables. Customers with an EV parked at home every day will have the v2g EV as a massive home battery backup. Customers who can plug in at work will do the same. Trickle all day long. 23hrs every day. 😊
@stephenbrickwood160217 күн бұрын
people do not understand that the grid itself has a large cost to the customer. That is seen in my 5cents kWh feedin and 50cents kWh supply. But if all your energy comes off your roof and you stop gas heating etc, and petroleum purchases and grid supply electricity usage then the benefits to the customers just gets better. Grid owners are terrified of this. The suggestion that the grid may have to turn off rooftop PV with higher feedin causing grid destabilisation is a worry that customers may not turn the grid back on. Just leave the grid turned off until the customer needs a little more to top off the home battery now and again. As the grid cost itself are fixed, costs will need to be shared with fewer customers. 4million rooftop PV today, EVs being charged from home, v2g Australian Standards are being developed. More and bigger rooftop PV being installed. 10, 13, 17kW systems. People are trading in their old EVs for newer ones. The v2g features will stimulate more trade-ins. Selfplug-in selfparking will add to the v2g.
@ZappedAU20 күн бұрын
Powerwall 3 or Sigenstor?!
@PatriciaJackson-u6i24 күн бұрын
Appreciate the detailed breakdown! Could you help me with something unrelated: My OKX wallet holds some USDT, and I have the seed phrase. (alarm fetch churn bridge exercise tape speak race clerk couch crater letter). How should I go about transferring them to Binance?
@Rags2Bags24 күн бұрын
i really no nothing when it comes to solar systems. i cant connect to the grid would a 6.6kw system be able to run 2 freezers 1 fridge and tv maybe some power tools and air compressor?
@aurion6125 күн бұрын
20mm corrugated conduit, Yuck, what with Electrician's, don't they know how to bend conduit anymore, everything the quickest and cheapest way.
@thereplacementfordisplacement25 күн бұрын
Would like to see Ron at Fronius explain to a customer that lost their system to a fire contributed to by Fronius in some reasonable accident that whole bike helmet inside your car analogy.
@thereplacementfordisplacement25 күн бұрын
Guaranteed in the 20-25 year life of your string inverter system you will need to replace it with a new one at least 2x so buying 3 inverters. For Enphase proven reliability is you will maybe replace 2 microinverters so you'll spend n+2 on microinverters.
@Iwishiwasflying25 күн бұрын
Well done and congrats Penrith Solar Centre
@EXD_voidz26 күн бұрын
Bullshit😂
@travschula27 күн бұрын
At that cost ...go with Echo flow..instead.
@paulkearsley9509Ай бұрын
I thought Tesla will be bringing a 3-phase inverter for Powerwall 3 in 2025
@dan23haslin25Ай бұрын
Hi Jake..We're building an all-electric home in Melbourne's south-east, opted in to use three-phase power. Now I'm doubting if I truly need the 3-phase. We are installing a 10kw solar system and considering putting the Tesla P3 as a battery backup. My concern is that one phase can power all of our electrical appliances, including heat pumps and split systems [23sq single storey home].Thank you!
@kiwidude8931Ай бұрын
Any issues with PW3 failures?
@marciogandolfiАй бұрын
Hi there, I'm in Brazil and I work with solar energy as well. What softare did you use for the layout of the solar modules? Very nice job!
@hifiky6882Ай бұрын
How did you run the wires between the two batteries? I don’t see any conduit, did you go out the back?
@opera5714Ай бұрын
I'm off grid and it is quite cheap to heat water with excess PV if you understand the technology. I designed a PV diverter to resistive heater that will only take the excess, be it 5W or 1KW, and puts that into heating water. It detects when array voltage exceeds the exceeds expected value and diverts only enough energy to bring that voltage back to Vmp. I didn't install any extra panels and it works fine in parallel with any MPPT charge controller. It costs less than $50US to build. I have a very minimal system and I can make enough hot water that my clothes washer uses hot water for every cycle. Amazing that everyone isn't doing this with units that China could easily produce. Solar people are just too technically challenged to understand this technology.
@TurreTuntematonАй бұрын
Looks nice. I also wait with great anticipation for the Enphase IQ 10p battery coming out Q1 2025. Should come at a similar price and enables all the inherent safety and other benefits of micro inverters systems: - Flexibility of panel placement on the roof. Can have different orientations as each micro and panel is independent . Can easily manage different roof levels as AC cabling more flexible. - System can be easily expanded later as you just add more panels with micros underneath. No need to change the whole central inverter. - Is very good managing shading - Safety as AC is low voltage and rapid shut down built in - Longer system life time and warranties compared to string inverters - Resilience. Should one micro fail then rest of system still producing - Module level monitoring and diagnostics - Sunlight backup without grid or battery power as long as there is sun (Enphase IQ8)
@marralim341Ай бұрын
Do you have tap the AP mode after successfully connected … or AP mode gets disabled automatically?
@bladerunner1458Ай бұрын
Thank you for all the information. My two power wall threes are working beautifully.
@bladerunner1458Ай бұрын
Thank you for your master classes. I have two powerwalls 3 in the USA. We have two wires and a neutral coming into our homes. The two wires are 180° out of phase and the neutral is between them. So each phase is 120 V and between the two out of phase wires are at 220 V. Almost all Outlets in our home are 110 V. Special appliances like a dryer electric stove, hot water heater most heat pumps and air conditioning are typically 220 V. The powerwall 3 supplies 220 V with a neutral so it can run the whole house. I have a Sawmill that runs on 220 V single phase 10 hp. Everything is running beautifully with 10K solar input. Very happy with the Powerwall 3
@bladerunner1458Ай бұрын
Thank you for your master classes. I have two powerwalls 3 in the USA. We have two wires and a neutral coming into our homes. The two wires are 180° out of phase and the neutral is between them. So each phase is 120 V and between the two out of phase wires are at 220 V. Almost all Outlets in our home are 110 V. Special appliances like a dryer electric stove, hot water heater most heat pumps and air conditioning are typically 220 V. The powerwall 3 supplies 220 V with a neutral so it can run the whole house. I have a Sawmill that runs on 220 V single phase 10 hp. Everything is running beautifully with 10K solar input. Very happy with the Powerwall 3
@bladerunner1458Ай бұрын
I have two power wall threes and they are working wonderful. thank you for the overview that has helped me interpret the Tesla app better
@gigyjose6134Ай бұрын
micro inverter will have clipping issues, max output for micro inverter is 480w there will be loss in this system
@stephenbrickwood16022 ай бұрын
Verandah in the roof space with Colorbond metal roofing would be safer with Enphase microinverters I would think. What can you tell me ?
@stephenbrickwood16022 ай бұрын
The roof attic space must be cooler under the PV panels. ??? 😎 ⛱️ 😎
@toni47292 ай бұрын
Excuse me, but Tasmania sun sets far later than it does in Queensland. Shouldn't that make a bit of a difference? When the sun sets in Qld, it's like someone switched a light off, it's that fast.
@jenniwoodruff64412 ай бұрын
What do you need for a one person occupant house?
@XxBloggs2 ай бұрын
Lost me at "I broke the solar industry". Pull the other one.
@s.lionelmcauley44552 ай бұрын
Jake, you have convinced me to sell my Enphase shares.
@bladerunner1458Ай бұрын
Should I buy Tesla stock?
@Hewagej2 ай бұрын
Great vi❤deo
@Topreddd2 ай бұрын
Yes you're right. Your huge battery storage will help it run longer but output will be maximised at 10kW only. On Single phase there is dostributor regulations, so despite the above limitation it will still be best solution as no distributor will approve more than 10kW Inverter capacity on Sngle phase
@kinjitex2 ай бұрын
bring on the DC OPTIMISERS
@kinjitex2 ай бұрын
can i run 2 POWERWALL3s on single phase ie 27kw?
@Topreddd2 ай бұрын
Yes ofcourse
@mattnbin2 ай бұрын
Recovery time is only quick in heat pump systems because of the traditional electric booster element!!!!
@s.lionelmcauley44552 ай бұрын
So, is Penrith Solar Centre dumping Enphase microinverters. TSLA is the best! Also, looking good there Jake, leaning out, keep it up, and congrats on the effort.
@John-B912 ай бұрын
How close together can Powerwall 3 batteries be placed on the inside of a brick garage and on a concrete floor?