Why is my Control Panel Chirping?
3:58
Is the Fujimac 80 for you? Short
1:06
Is the Fujimac 80 for you?
3:48
Жыл бұрын
Is the HiBlow 80 For You?
3:10
Жыл бұрын
What Septic Pump Do I need?
22:49
Жыл бұрын
Aerobic Control Panel Overview
2:39
Septic System Riser Kit Install
11:05
Duplex Panel Overview
4:51
Жыл бұрын
Dosing Panel Overview
3:16
Жыл бұрын
Septic System Panel Overview
4:39
Simplex Panel Overview
2:18
Жыл бұрын
Simplex Control Panel
2:41
Жыл бұрын
Septic Riser Location and Sizing
8:38
My septic air pump will not turn on!
7:30
Пікірлер
@wrtrmike
@wrtrmike 9 күн бұрын
A recent experience with rebuilding a Hiblow. It’s highly important to obtain genuine Hiblow parts. I found out there are some inexpensive knockoff parts that can end up causing you more problems…
@wholesalesepticsupply9801
@wholesalesepticsupply9801 7 күн бұрын
@@wrtrmike Yes it is very important to get real kits.
@ascent42
@ascent42 24 күн бұрын
Publish the video of running this engine with 220 in 220 out vfd. I am waiting in curiosity.
@rodgeri2892
@rodgeri2892 27 күн бұрын
thanks mate, usefull tips, got me up and running again
@wholesalesepticsupply9801
@wholesalesepticsupply9801 26 күн бұрын
@@rodgeri2892 your very welcome
@jonbfrom254
@jonbfrom254 29 күн бұрын
Thank you fof making thus video it has helped me out tons i was gokng crazy lookkng for saftey screw.
@YannuPapi
@YannuPapi Ай бұрын
My pump runs but water wont come out to the sprinklers ive tried rinsing it off with a garden hose but still no luck could use some help
@YannuPapi
@YannuPapi Ай бұрын
I have a sta rite high head pump
@wholesalesepticsupply9801
@wholesalesepticsupply9801 Ай бұрын
@@YannuPapi spray heads might be clogged, you may also need a clean out. have you pulled the pump out.
@Needfreedom8953
@Needfreedom8953 Ай бұрын
Great in depth installation video. Thanks for taking the time!
@Babihrse
@Babihrse Ай бұрын
Didn't know Americans used connector blocks. A bit of both in play wire nuts and connector blocks.
@josephcashdan4309
@josephcashdan4309 Ай бұрын
This video doesn't in any way answer what type of air pump you need for a specific application. It explains how to determine what type of pump you have, so you can obtain the proper rebuild kit for it.
@stevenwood7131
@stevenwood7131 Ай бұрын
I have a liberty FL51M effluent pump. The pump runs at 120 volts AC at 12 running amps. Many mechanical floats I've seen are 13 amp rated. Would it be OK to run with a 15 amp float to give the eff. pump a leeway without damage to any component (pump or float)? What float brand is compatible with the FL51M? I Have a SJE Rhombus dose timer control box. I need a float that has the low level cut off (not the alarm float)
@wholesalesepticsupply9801
@wholesalesepticsupply9801 Ай бұрын
@@stevenwood7131 yes it will be fine
@chrisosborn1693
@chrisosborn1693 Ай бұрын
A great video and very informative. Many thanks.
@natalieavalos2520
@natalieavalos2520 Ай бұрын
What if the white lever does not stay in place? Can that be replaced?
@wrtrmike
@wrtrmike Ай бұрын
I have an HB 80 that had bad diaphragms which I replaced. The overheat screw is fine as it didn’t overheat… but the white power lead going to the coil keeps burning off… I solder it back on and the pump will run for a while only to reborn that wire off… suggestions?
@mardigrasqueenofthesouth8847
@mardigrasqueenofthesouth8847 Ай бұрын
thanks for this, the installer didnt give me a walkthrough
@robert574
@robert574 2 ай бұрын
I'm working out the connections at the tank. I used to have the 4x4 wood post, outlets and alarm box with the 3 cords (pump and 2 float switches). I have a new septic panel and disconnect to go on the wall like you have. The remaining issue is bringing the 3 cords from the tank (about 6ft from the wall) to the control box, there is no unground "box", just cords coming out of the tank. I bought a 10" round x 12"dp sprinkler box and I'm planning to run a conduit underground and glue a 4x4 sealed box on the end with 3 sealing cord connectors in the sprinkler box. If the float and pump cords aren't long enough, I'll put a sealed splice on them so they are continuous through the conduit with no connections underground. When it comes time to replace one, it can be fed through the conduit without having to dig up all the wiring again. What do you think? I don't see much if anything readily available for the actual tank connections or any videos.
@themaster11199
@themaster11199 2 ай бұрын
Awesome info! Just did a rebuilt on mine and couldn't find any info on the small hose.
@Leo-gm5cv
@Leo-gm5cv 2 ай бұрын
Let's say the power was out for 3 days and the aerobic bacteria all died. What are the following steps for recovery?
@wholesalesepticsupply9801
@wholesalesepticsupply9801 2 ай бұрын
@@Leo-gm5cv Turn the aerator and they will re establish a colony pretty fast. When a system first goes in there is nothing in the system and they do just fine building a colony out. It might smell for a couple days that is from the aerator being out and it’s normally only noticeable on a spray system.
@Leo-gm5cv
@Leo-gm5cv 2 ай бұрын
@@wholesalesepticsupply9801 Thanks! That's easy enough. I was afraid I need to put in some additives and/or do something extra to re-gain normal bacterial operation.
@davekoch317
@davekoch317 2 ай бұрын
My wiring had to go out from the holding tank through 1" conduit, so I had to cut the plug-ins off. Once I got the wiring pulled through, I couldn't figure out how to wire it. Followed your instructions and I was in business in 10 minutes. Thanks man!!
@eugeneandrew5011
@eugeneandrew5011 2 ай бұрын
Thanks a lot! Watching from Russia. Best video on how to fix this thing.
@wholesalesepticsupply9801
@wholesalesepticsupply9801 2 ай бұрын
@@eugeneandrew5011 Thank you.
@MT_Pant_Suit
@MT_Pant_Suit 3 ай бұрын
Thanks much
@genewoodell6970
@genewoodell6970 3 ай бұрын
Well done video. Quick, but not too fast. Good sound and camera. Thanks for having background music low enough so we can hear what the speaker is saying. Mostly this procedure will be done out in the sun on the ground since the units are usually hard wired so I like to have all of the wrenches and pieces ready to go as to do it quickly, if that is possible. I heard the diaphragm nut is a 7mm? The set screw is kind of a mystery for me as I have not done the replacement before. I also heard you can rebuild the units 2-3 times and then the unit will need to be replaced. Thank you for the informative video.
@gaspervidovic8089
@gaspervidovic8089 3 ай бұрын
@wholesalesepticsupply9801 I unscrewed the 4 screws on the casing, but can't get it open. It's hard to apply force to get it apart. Is there another screw or why does it stick that hard together?
@wholesalesepticsupply9801
@wholesalesepticsupply9801 3 ай бұрын
@@gaspervidovic8089 rubber mallet works well it does happen sometimes
@donpreble2380
@donpreble2380 2 ай бұрын
How hard do I hit it with the rubber mallet?
@keevincomeaux2281
@keevincomeaux2281 4 ай бұрын
How do you reset the pump with the old safety switch?
@wholesalesepticsupply9801
@wholesalesepticsupply9801 4 ай бұрын
@@keevincomeaux2281 you can’t if it’s a screw type you need another screw. if it’s the slide stop then you move it back to the position that depresses the switch. on the slide type it sometimes wears down and you need to hold it in position the best thing we have found without completely replacing it is to fold a business card and slide it in to hold the switch down.
@johnacord6224
@johnacord6224 4 ай бұрын
Best vedio yet. All the others showed the older version. So thank you, thank you, thank you. I thought I was from another planet 😊
@bobbattiste980
@bobbattiste980 4 ай бұрын
Ok so I have a water proof box in my tank and a receptical, the white wire melted off and the black connection has a small burn mark , any ideas?
@wholesalesepticsupply9801
@wholesalesepticsupply9801 4 ай бұрын
@@bobbattiste980 Run new wires is your best bet.
@bobbattiste980
@bobbattiste980 4 ай бұрын
I run a new heavier wire, was 16 gauge, and replaced with 12
@ralphwilliams5589
@ralphwilliams5589 4 ай бұрын
Trying yo find out the difference in the HP-80. What is the 1120, 1112, 1127 after the 80. What is different
@wholesalesepticsupply9801
@wholesalesepticsupply9801 4 ай бұрын
@@ralphwilliams5589 nothing internally some have conduit slips on the wire on the outside but overall and performance wise they are the same.
@mathieupetit6001
@mathieupetit6001 4 ай бұрын
Thank you worked for me
@flintknappingtools
@flintknappingtools 4 ай бұрын
On a 220v pump….does the float switch need to have the ability to open or close both HOT wires? Seems odd that just one hot would be switched and one would remain energized. Thanks for your help
@andreacasto160
@andreacasto160 4 ай бұрын
I’ve never worked on something like this before and I am so thankful for you! This video helped me save my mom 1500 to replace and install a new aerator. I did it for the cost of the kit. I appreciate the guidance.
@SeanCreswell
@SeanCreswell 4 ай бұрын
where did the screw go??
@aprilzeringue6519
@aprilzeringue6519 4 ай бұрын
My issue was a tube that was disconnected. Super simple solution. I freaked out over a simple solution.
@wholesalesepticsupply9801
@wholesalesepticsupply9801 4 ай бұрын
@@aprilzeringue6519 sometimes it is that simple always good to check and see yourself.
@rhymereason3449
@rhymereason3449 4 ай бұрын
1.5 hours to do it... 2 months to deal with the code people... (if your location allows a non-licensed electriction do it at all).
@Jack-Surreal_Panes
@Jack-Surreal_Panes 5 ай бұрын
I got the 80 retro. Only modifications I did was a flat lid for it to sit on top of tank..The second was an elbow where the 1/2 Flex comes out the bottom. instead of the curve from the hose I added an elbow so the areator line enters center of lid rhen down and added a conduit clip to support the hose. The air pump is so much better tham that shaft areator. The smells pver the last 16 years are gone when sprinklers come on. When heavy rains come and flood the chambers it still areates, less electricity. No more shaft bearings going out burning out theotor or popping the fuse
@Turbosha777
@Turbosha777 5 ай бұрын
Thank you, this video was very helpful.
@wholesalesepticsupply9801
@wholesalesepticsupply9801 4 ай бұрын
@@Turbosha777 Gald you liked it.
@JH-bf1bv
@JH-bf1bv 5 ай бұрын
Looks to be a 1/4” port in the side. What is that for?
@wholesalesepticsupply9801
@wholesalesepticsupply9801 5 ай бұрын
@@JH-bf1bv it’s for the little air hose that goes to the switch for the low air alarm activation.
@radiocjl
@radiocjl 5 ай бұрын
Our air pump is working fine but liquid in the aeration tank has stopped bubbling - was recently pumped out and thinking something got disconnected (diffuser?) or dislodged. There is a check valve in the airline from the air pump - could that be part of the problem? Nyadic 600 gal.
@wholesalesepticsupply9801
@wholesalesepticsupply9801 5 ай бұрын
@@radiocjl could be you in a nyadic you would hear air because of how they are set up. you can see most of the pipes inside the tank they are not hidden. so if you can’t hear air or see it bubbling it’s probably disconnected where it comes into the tank or close to the aerator. you can call the office our family has installed nyadic for 25 years so we know just a little bit about them lol.
@radiocjl
@radiocjl 5 ай бұрын
@@wholesalesepticsupply9801 Thanks for your comments! It seems the issue may be with the check valve as I knocked it a bit with a pole and got bubbling to resume. So, am thinking it's not the diffuser down at the end of the airline piping. We have an older M-6 Nyadic.
@wholesalesepticsupply9801
@wholesalesepticsupply9801 5 ай бұрын
@@radiocjl Call our office we never put a check valve on ours. if it’s a diaphragm pump it’s not needed as it would never vacuum in. If you have a rotary vane unit it could possibly have one we never put one on with our nyadic units but doesn’t mean you don’t have one. Call the office monday i will help you.
@raydelfa1125
@raydelfa1125 5 ай бұрын
Anyone can make a video...lmao..
@raydelfa1125
@raydelfa1125 5 ай бұрын
Your wrong bro!
@iconoclad
@iconoclad 5 ай бұрын
I found the alignment tabs on a new diaphragm repair kit were not quite vertical. This caused the magnet to be misaligned/sloped. The resulting vibration destroyed the switch such that it was locked on and went on and disintegrated the new diaphragms and bellows. Bits of plastic everywhere.
@wholesalesepticsupply9801
@wholesalesepticsupply9801 5 ай бұрын
@@iconoclad where do you buy the kit i’m guessing amazon.
@iconoclad
@iconoclad 5 ай бұрын
@@wholesalesepticsupply9801 Ebay and Aliexpress. I haven't figured out yet which were faulty. I suspect some are made of inferiour materials.
@JeffZiegler76
@JeffZiegler76 5 ай бұрын
Being the rings only come in 6" & 12". Can you cut them down? Do you take it off the top or bottom?
@wholesalesepticsupply9801
@wholesalesepticsupply9801 5 ай бұрын
@@JeffZiegler76 no you can’t they come in 3,6,and 12
@Timeshifter32
@Timeshifter32 5 ай бұрын
Awesome tutorial guys. Thank you so much!
@Jack-Surreal_Panes
@Jack-Surreal_Panes 5 ай бұрын
old video but worth a shot. my installers screwed up 17 years ago and issues since. the 1.25 pvc comes in riser almost at tank level with a typical elbow box. Flooding during heavy rains so all the switches and pump wired there. I am adding an elbow and bring the box near top since difficult to seal 4 sets of wires into this WP lidded box. I am trying to run buried flex conduit for pump, probably use 12/2. The floats, probably use TW wire but see other shielded stranded wire a fraction of the 20' needed, so 120' for all 6 wires. Would I be OK running waterproofed similar wires to the floats probably 14G 15 amp?
@wholesalesepticsupply9801
@wholesalesepticsupply9801 5 ай бұрын
@@Jack-Surreal_Panes i would run 12g for 120 ft it also depends on what was ran from the main breaker box to to control panel.
@Jack-Surreal_Panes
@Jack-Surreal_Panes 5 ай бұрын
@@wholesalesepticsupply9801 I got 25' of Gear It SJOOW 12/3 power cable. Sturdy water proof durable wire. Running 14 THWN for 3 floats, that is what, well, THHN, now. Since the D elbow hole is almost directly at tank opening I an running all new wires to new box as well as using 1" 90s and a 45 to mount a waterproof box on riser wall. All connections watertight not. Currently is 14 wire and I see Romex. Since the D box was co stantly looded no wonder the floats were always messed up and fried my Norweco box. The only.reason my pump lasted was when I replaced it I used the waterproofing nuts with self fuse tape. so the pump and on off float could withstand being submerged for days. I have to blow out the 1" but unless a super flood all com.ections should wothstand a bit of flooding. I gotta say the air pump conversion is amazing. Got a whirlwind. I got a flat riser lid and it sits on top. added an elbow for spa tubing can drop straight down bit. OMG the smells almost disappeared when sprinklers go on. The old shafts can't compare plus if it floods the aerator will.still diffuse and not blow and tear up bearings. Been watching the float set ups and I may keep the float where it is but lower the override and set the alarm just before the inlet pipe. That should alert me that the water level is almost at the bio filter outlet. I am definitely taking that class to do own servicing and reporting to the county. I nearly.rebuilt an entire septic mechanically. Thanks for these videos. They really do help. Septic companies gotta eat too but 700 for wiring a new box, 30p for bio fter clean, 100 per float These cost can kill a person financially.
@mewshifter
@mewshifter 5 ай бұрын
we don't sell a rebuild, hiblow does, guess I know who i am buying the replacement from since these POS break every 1.5 years (it was the 80s, they are just as faulty imo)
@amandaarnold3486
@amandaarnold3486 5 ай бұрын
Hi! Loved this video! I would love to connect and chat with you about an issue we are currently having. We have spoken to 4 Septic Engineers, plumbers, and other Septic professionals and they are ARE stumped. We are desperately searching for answers for a problem we are having. We are located in California. Are you available to chat via phone for a consultation so we can explain our situation and hear your thoughts? Thank you!
@wholesalesepticsupply9801
@wholesalesepticsupply9801 5 ай бұрын
@@amandaarnold3486 sure you can call the office at wholesale and ask. you willl need to to ask for reuben and tell him I said it’s okay. he is also very knowledgeable about septic. it is difficult not being onsite to figure out things but we can usually narrow it down to a couple of things it will be.
@amandaarnold3486
@amandaarnold3486 5 ай бұрын
@@wholesalesepticsupply9801 Thanks for the response! We have recently discovered that our WEEKLY cleaners were cleaning showers/toilets/bathtubs with chlorine bleach. About 5-8 cups worth of bleach each week. So our tank was getting 20-30 cups of bleach per month since March. We have since gotten our tank pumped (2 weeks ago), and were advised to add baking soda to the septic (which neutralizes the bleach) and are also adding weekly commercial septic bacteria compound to the tank. The cleaners did come once before we put two and two together. The company we purchased the commercial septic bacteria from said for 5-8cups of bleach could take 6-8 weeks to rebalance the tank, Right now we are just being patient and going 100% bleach free for the 6-8 weeks to see if we see (or smell) any improvements.
@IronHorse2007
@IronHorse2007 5 ай бұрын
Dumb question. Why do you put water back in when you called to have it emptied?
@wholesalesepticsupply9801
@wholesalesepticsupply9801 5 ай бұрын
@@IronHorse2007 on a aerobic septic a pump discharges the water in most applications. You are cleaning it to remove solids not water. Aerobic systems are sometimes fiberglass so it’s important they have weight added to them so they don’t float out of the ground is one reason. also the alarm switch needs back pressure to engage the switch properly or the alarm will go off endlessly until that tank has water in it. since it is the second tank depending on how many people that could be days so we fill the aerobic unit so this doesn’t happen.
@IronHorse2007
@IronHorse2007 5 ай бұрын
@wholesalesepticsupply9801 Thank you for explaining that.
@riversongblest
@riversongblest 5 ай бұрын
Excellent..thanks
@pepeepupoo
@pepeepupoo 5 ай бұрын
I love youtube
@acepokemontrainer1
@acepokemontrainer1 6 ай бұрын
Do you recommend this fujimac 80 for koi pond aerator? I am deciding between this one and a Medo-80bn. My pond is 10,000 gallons 6 feet deep and I'm planning to spread amongst two 9 inch dics diffusers (matala). Located in NC. Among the koi hobbyist everyone knows and trust Medo for longevity, but not many talk about fujimac. But this one you talk about sounds pretty comparable, if not better.
@wholesalesepticsupply9801
@wholesalesepticsupply9801 6 ай бұрын
@@acepokemontrainer1 that’s a great choice same pressure output at 80 lpm Fuji Macs have a 5 year warranty also.Medo was sold directly to pond dealers is why they are not as popular. Japanese koi food maker Hakari actually had them as their preferred aerator branded for them but never really did anything in the states with them. The Hiblow XP 80 is also a great choice.
@Latest68
@Latest68 6 ай бұрын
Hi, can i use the same diaphragm for the xp80, than for the hp80? Thanks, Good Job!
@wholesalesepticsupply9801
@wholesalesepticsupply9801 6 ай бұрын
@@Latest68 no
@Ymiyt
@Ymiyt 6 ай бұрын
THANK YOU SIR! CLEAR,THOROUGH, AND CONCISE. I APPRECIATE YOU.
@Uncle_Matt_
@Uncle_Matt_ 6 ай бұрын
Any videos showing how to rebuild one that has a safety screw?