Пікірлер
@tjsylla
@tjsylla 5 жыл бұрын
Sounds like Human valve..lol
@leehart9055
@leehart9055 6 жыл бұрын
Why does you rdept not use 5 inch hose. Just curious not critisizing...
@Bravo-Too-Much
@Bravo-Too-Much 4 жыл бұрын
They are using 5 inch.....
@Wirdgetrunken
@Wirdgetrunken 3 жыл бұрын
@@Bravo-Too-Much He's talking about the secondary portion of the HUMAT. That's a 3" on the secondary.
@pilotbartramnon-flyingvide7684
@pilotbartramnon-flyingvide7684 6 жыл бұрын
Are you suppose to drain the Hydrant before you connect the Humat? I've see departs do it some don't. Mainly because when you first open a Hydrant what comes out isn't water. I guess you wouldn't have to worry about that at the academy. However a general rule of thumb do you drain the plug first so that stuff doesn't get into your pump?
@refusecollectionofsanjose
@refusecollectionofsanjose 7 жыл бұрын
How many engines, ladders, command vehicles you guys have? How many stations?
@craigscherer563
@craigscherer563 7 жыл бұрын
In the city there are 32 structural fire houses with 29 engines, 6 district assistant chiefs, 6 towers, 9 trucks, two rescues and one Hazmat rig. The airport has 2 structural houses and 3 ARFF stations with two engines, two smaller engines (similar to a type 6) for airport tunnel suppression, a red chief, a truck, a hazmat rig and 6 crash trucks City side also has two type 6 and one type 3 wildland rigs, normally unmanned. Both city side and airport have a command rig but neither is regularly used. Station 39 breaks ground this year and station 40 next year.
@macktruck6407
@macktruck6407 7 жыл бұрын
Curious...? Your department doesn't use the 5" for supply line? If not , in what application would you use it since you have it on the engine?
@denverfiredepartmentsafety9391
@denverfiredepartmentsafety9391 7 жыл бұрын
We have four engines equipped with 5 inch supply. The rest of our engines are equipped with A 4 way Humat valve and Three inch supply line. In situations that apply first in Company can lay in with the Humat valve and 3 inch line drop a second 3 in line and second arriving Engine can work at the plug and supplement the water supply. The 5 inch companies have the discretion to lay in with the 5" or the Humat Valve depending on the situation. I hope that answers your question.
@macktruck6407
@macktruck6407 7 жыл бұрын
Great, thank you.