#DG ,LOAD CALCULATION OF DG
4:19
4 жыл бұрын
#ACB, Air circuit breaker maintenance
28:07
How to install AVR in CAT 500 KVA DG
4:19
Sinamic V20 master reset
0:48
5 жыл бұрын
How to run reverse ATV 310 VFD
1:53
5 жыл бұрын
How to convert Kva to Amps
0:27
5 жыл бұрын
How to convert kw to Hp
0:17
5 жыл бұрын
Bursting strength tester repairing
2:56
How to crimp an Ethernet cable....
1:54
HT cable maintenance Full tutorial
13:48
Home Automation with smart phone
8:55
Selec  TS2M1
7:01
5 жыл бұрын
Пікірлер
@T-Elecrical
@T-Elecrical 24 күн бұрын
@DhrubajyotiDeka-i9y
@DhrubajyotiDeka-i9y Ай бұрын
Moja🔥🔥
@DhrubajyotiDeka-i9y
@DhrubajyotiDeka-i9y Ай бұрын
Moja🔥🔥🔥
@DhrubajyotiDeka-i9y
@DhrubajyotiDeka-i9y Ай бұрын
Moja🔥🔥🔥
@supdasaaf
@supdasaaf 3 ай бұрын
Thanks..
@firozshaik4494
@firozshaik4494 3 ай бұрын
Nice video
@usmanshoukat5488
@usmanshoukat5488 4 ай бұрын
Is the input voltig of this AVR 110?
@vikasrana88
@vikasrana88 5 ай бұрын
Single phase ke liye formula?
@madhupathiyil9251
@madhupathiyil9251 5 ай бұрын
Nice timer, very easy to program, no complications ❤
@allrounderrk7341
@allrounderrk7341 5 ай бұрын
👍👍🙏
@ImranKhan-ot2eo
@ImranKhan-ot2eo 6 ай бұрын
Subha 6,oo baje on karna,12,30 baje band karna h,,and fhir shaam ko 6,baje fhir on hoga 12,30 band karna h please set video aplod kare
@ImranKhan-ot2eo
@ImranKhan-ot2eo 6 ай бұрын
Ak din do on off karna hai kese set karenge sir
@aliabdullah2928
@aliabdullah2928 6 ай бұрын
अबे ठीक से बता साले, झांट नही हो रहा कलिब्रेट
@ManjitSingh-nv4uz
@ManjitSingh-nv4uz 6 ай бұрын
Sir single supply ka parsents kasa nikla gya ov uv kya
@MalikJi-om5js
@MalikJi-om5js 7 ай бұрын
if we want to install VFD with FAHU how can we use thermostat. pleas explain with wiring diagram
@sashikantapanda2831
@sashikantapanda2831 7 ай бұрын
Sir please give a number
@gauravsharma-gc4cp
@gauravsharma-gc4cp 10 ай бұрын
Sir motor ka direction change ka bhi parameter btaye❤❤
@ajaylohar5007
@ajaylohar5007 10 ай бұрын
Thanks sir
@arvindsingh7355
@arvindsingh7355 10 ай бұрын
Red light blinking continuisoly
@arvindsingh7355
@arvindsingh7355 10 ай бұрын
Sir vfd display not showing anything only red light is blinking then what I do??
@mandeeptark
@mandeeptark 11 ай бұрын
auto on kaise hota hai???
@a-b-c628
@a-b-c628 11 ай бұрын
what´s the name of the blue paper?
@vikaskumar5497
@vikaskumar5497 11 ай бұрын
06 error kaise sahi hoga
@neilray9522
@neilray9522 Жыл бұрын
Promo SM 💖
@kabirajsyamal7695
@kabirajsyamal7695 Жыл бұрын
Po 109 paramer kiya hai
@deepakparida2749
@deepakparida2749 Жыл бұрын
Thank you for your valuable video
@mumraizakhtar3994
@mumraizakhtar3994 Жыл бұрын
Nice
@technicaljd4823
@technicaljd4823 Жыл бұрын
Thanks
@siliveriajay30
@siliveriajay30 Жыл бұрын
Am pm not showing
@abdelazizchebbi2814
@abdelazizchebbi2814 Жыл бұрын
Qui peut traduire la vidéo en français ou en arabe ?
@jumantos-technic3677
@jumantos-technic3677 Жыл бұрын
Thank you 🙏
@luisnunez1009
@luisnunez1009 Жыл бұрын
Si este equipo es de 440 volts no trabaja con 220 volts de linea
@rasikbambole185
@rasikbambole185 Жыл бұрын
Very Good explained... thanks
@TheHarman49
@TheHarman49 Жыл бұрын
Thanks bro
@inn2558
@inn2558 Жыл бұрын
How many ohms the exciter field this generator??
@beewbethel5221
@beewbethel5221 Жыл бұрын
Thank you sir ji
@ambassadorkees
@ambassadorkees Жыл бұрын
Still can't fathom how total disregard of safety and maintenance instructions there's guys are showing!
@KARMMAROC
@KARMMAROC Жыл бұрын
indeed but they know what they are doing for real
@ambassadorkees
@ambassadorkees Жыл бұрын
@@KARMMAROC Obviously not. They have drawn up their own action plan that looks nice to lay people on video. But in fact, they make about 20 dangerous mistakes and worsen the condition of the breaker, omitting the THREE most important things that should have been done.
@ambassadorkees
@ambassadorkees Жыл бұрын
@@KARMMAROC found my detailed list of a year ago: It still misses a few points, e.g. Level 2 or L3 maintenance training is obviously not received. These guys shouldn't be working on this breaker at all! Clearly NOT according to good ABB standards and practices: 😢 Let me spell it out: Fault #1: Not using protective clothing (hard-nosed shoes, arc protection, gloves etc) Fault #2: Breaker has been racked-in with excessive force Fault #3: Disconnecting breaker with open door. 😡 This shall be done with closed door, since the door is supposed to contain any arcs. Fault #4: Servicing the breaker with spring charged. Shall ALWAYS be discharged before any service or installation. EVERY mounting instruction starts with: OPEN and DISCHARGED. Danger for hands! Especcialy when 8:40 they remove the cover of the charged spring & trip mechanisms!! This makes me 😡 as well. #5 WD-40 is NOT an approved cleaning agent. Instructions 1SDH000460R0002 chapter 8 mention using dry and clean cloth and only for EXCESSIVE deposits Henkel 273471 or equivalent. #5a Sand paper 😱! Who came up with that idea? #6 7:35 is there debris on the bottom of the arc chamber? No cleaning performed. All WD40 and copper residue increase the risk of arc flash. Fault #7 8:55 - 9:28 and 21:34 Excessive forces used again. 😢 Supposed to be only 3Nm on the coil assembly according to mounting instruction 1SDH000579R0001, and 9Nm on the motor acc to 1SDH000460R0605, read up. Mind you, just last week had to visit a client whose molded case breaker disfunctioned only due to excessive torque on a cover. #8 12:17 I'm quite sure WD-40 not allowed or suggested in there as well! Fault #9 Puts his fingers into the mechanism area while the spring is still charged!!! 😧😧 13:17 and onwards! My stomach turns. Fault #10 Re-greasing with springs charged, not using a brush (can't reach where you have to), the WD-40 removed grease between hinges and other bearing surfaces, since the springs are charged, the forces on these surfaces are active and no grease will replace the washed away... Result: You SEE grease, but the necessary functional mechanisms are NOT LUBRICATED 🥺😢 17:33 FINALLY he discharges the springs, only to test the charging immediately afterwards... Fault #11 Small, non-dangerous mistake: They didn't timely realise the UVR / YU should be removed to allow testing. 😅 Fault #12 20:47 The carbon paper test is OK, but do you see the contacts aren't clean even with WD-40 and cloth? All over the paper there are black marks. Cleaning not succesful? Fault #13 23:42 Put the breaker back in fixed part with the relay cover reversed. It might easily get damaged. Fault #14 23:54 Racking in with OPEN DOOR. This is the most common situation to achieve arc flash. Fault #15 Doesn't check auxiliairy wiring 0,7Nm tightness as per manual. Fault #16 24:13 Closes door and ends work with still a reversed relay cover, and is proud of it! 😅 Fault #17 Ends project without doing a trip test using the PR030/B, Ekip T&P, PR010/T or other trip test equipment. Without a trip test, you can't call the breaker "serviced". Fault #18 Ends project without performing functional tests acc. to 1SDH000460R0002 chapter 8.3.9. Fault #19 Don't see a sticker with service date & signature. Fault #20 Ends project without the motor recharging the breaker (probably aux voltage not switched back on). Falut #21 Video ends with 4 minutes of empty black. Well, that last comment: I'n not a video editor, how would I know`? I'm only a ABB Technical Support Specialist.
@bantupallisiva2123
@bantupallisiva2123 Жыл бұрын
Dear sir. Please need to update calibration video
@pramodkumar9935
@pramodkumar9935 Жыл бұрын
इसका माडल नंबर क्यों नही दिखाया
@rambhualpal4914
@rambhualpal4914 Жыл бұрын
Thanku so much sir apka video bahut acha laga
@baskarchandrakasan995
@baskarchandrakasan995 Жыл бұрын
Good explain sir 👍
@AKASHDAS-ic9kh
@AKASHDAS-ic9kh Жыл бұрын
Thanks for you bro
@techabhijit5304
@techabhijit5304 Жыл бұрын
What is programming?
@kohein7918
@kohein7918 Жыл бұрын
OU2 error Why? bro thank
@fariedel3791
@fariedel3791 Жыл бұрын
Good Job!
@mattt8382
@mattt8382 Жыл бұрын
Very helpful
@arunpratap3318
@arunpratap3318 Жыл бұрын
Poor post why music is there
@devadon5607
@devadon5607 Жыл бұрын
Really suberb brother ✨
@aecpenginering7053
@aecpenginering7053 Жыл бұрын
Very good..sir ji
@aecpenginering7053
@aecpenginering7053 Жыл бұрын
Thank you sir
@aecpenginering7053
@aecpenginering7053 Жыл бұрын
Thank you so much...for solving my problem... sir can you provide your phone number...