@aaronbratcher6197
@aaronbratcher6197 17 күн бұрын
🫣💩💩💩🥵
@TomLawson05
@TomLawson05 24 күн бұрын
Great job troubleshooting and fix. Thanks for the video
@ThePeavey23
@ThePeavey23 Ай бұрын
That install looks like a bunch of Mexican/hacks did it.. work pride has gone out the window
@Knightransport
@Knightransport Ай бұрын
Grest job explaining your troubkeshooting process. Thank you so much bro.
@divine7877
@divine7877 Ай бұрын
Please send me mail I need your assistance
@campwayde
@campwayde 2 ай бұрын
Nice job taking your time to explain everything so good. Nice job with this installation, you guys know what you are doing at Iron Shield. Thank you for sharing! Keep them videos coming please.
@veronicasofia7544
@veronicasofia7544 2 ай бұрын
checking these pressures and temperatures at the compound gauge,. first when refrigerant was added and sub cooling went up, but the super heat stayed the same, including the low suction pressure did not increased meaning you have a liquid line restriction , or txv problem,
@henrydang1644
@henrydang1644 2 ай бұрын
Thank you so much for the video
@bagtube
@bagtube 2 ай бұрын
To address a low VSAT (Vapor Saturation Temperature) reading, which is an indication of the temperature at which refrigerant evaporates in the evaporator coil, you should consider the following potential causes and corrective actions: Potential Causes: Low Refrigerant Charge: Insufficient refrigerant can cause the evaporator coil temperature to drop. Dirty Evaporator Coil: A dirty coil can restrict airflow, leading to lower temperatures. Restricted Airflow: Blocked or dirty air filters, closed vents, or obstructed return air can cause reduced airflow over the evaporator coil. Thermostatic Expansion Valve (TXV) Issues: A malfunctioning TXV can cause improper refrigerant flow, leading to incorrect temperatures. System Overload: High indoor humidity or excessive heat load can cause the system to struggle, affecting the VSAT. Incorrect Superheat or Subcooling: Improper superheat or subcooling settings can indicate an issue with refrigerant flow or charge. Corrective Actions: Check Refrigerant Levels: Verify the system has the correct refrigerant charge and add refrigerant if necessary. Clean the Evaporator Coil: Ensure the evaporator coil is clean to allow proper heat exchange. Inspect and Clean Air Filters: Replace or clean dirty air filters to ensure adequate airflow. Check Airflow Path: Make sure all vents and returns are open and unobstructed. Evaluate TXV Operation: Check the operation of the TXV and replace if it’s malfunctioning. Check for Air Leaks: Inspect the ductwork for any leaks that could be affecting airflow. Assess Load Conditions: Ensure the system is not undersized for the cooling load and check for excessive humidity or heat sources in the space. Adjust Superheat and Subcooling: Make sure superheat and subcooling levels are set correctly according to manufacturer specifications. Steps to Increase VSAT to 34 Degrees: Ensure Proper Refrigerant Charge: Add refrigerant if the charge is low. Improve Airflow: Clean or replace air filters and ensure all vents and returns are clear. Clean the Evaporator Coil: Remove any debris or buildup on the coil. Inspect TXV: Make sure the TXV is functioning correctly and adjust if needed. Check for System Load: Reduce any unnecessary load on the system, such as high indoor humidity or heat sources. By systematically checking these potential causes and making the necessary adjustments, you should be able to raise the VSAT to the desired 34 degrees.
@mrbillpurcell6203
@mrbillpurcell6203 2 ай бұрын
proof your a hack ! no scale to measure , your a thief ,
@mrbillpurcell6203
@mrbillpurcell6203 2 ай бұрын
what's wrong with your eyes , baggy an dark circles , , why aren't you using manufacturer chart , you hack
@Ojeramup12
@Ojeramup12 2 ай бұрын
Do most techs use this system of superheat and subcooling?
@ironshieldheatingair5751
@ironshieldheatingair5751 2 ай бұрын
@@Ojeramup12 you would be surprised how many techs are unfamiliar with it.
@Ojeramup12
@Ojeramup12 2 ай бұрын
@@ironshieldheatingair5751 That's exactly what I thought. Thanks.
@ironshieldheatingair5751
@ironshieldheatingair5751 2 ай бұрын
@@Ojeramup12 no problem 🤝🏻
@luislibre9616
@luislibre9616 2 ай бұрын
Thanks for your videos im a new technician and this really helps a lot.
@myerschase23
@myerschase23 3 ай бұрын
Hey brother thanks for sharing. I’m out in Texas in the trade also and you do a great job with explaining the systems functions in a way those can understand. Much appreciated. I have been a lead installer for 4 years but I also do service. Sometimes those Goodman comfort net systems can be a pain because of that firmware. Anyway thank you man keep up the good work
@ironshieldheatingair5751
@ironshieldheatingair5751 2 ай бұрын
Thank you for sharing that with me. Stay cool out there!
@peerod673
@peerod673 3 ай бұрын
So glad I'm out of the residential field I'd be the one to go back out after someone charged to gas a unit up and I go back to remove a dirty filter or tell them their coil is dirty.
@ironshieldheatingair5751
@ironshieldheatingair5751 3 ай бұрын
Ooof! I feel your pain buddy. That’s no fun
@chesstime356
@chesstime356 3 ай бұрын
Just subscribed your channel
@ironshieldheatingair5751
@ironshieldheatingair5751 3 ай бұрын
Welcome! 🫡
@keshaunlewis9825
@keshaunlewis9825 3 ай бұрын
Do you have your epa 608 certification or diploma cuz I’m in trade school right now I need to know which I need to get
@ironshieldheatingair5751
@ironshieldheatingair5751 3 ай бұрын
EPA 608 universal cert 👍
@nickma71
@nickma71 3 ай бұрын
Interesting how MVAC testing is so different. In MVAC, the manifold gauge tells you everything. Superheat and sub cooling isn't calculated. Charts are very common showing operating pressures at different temps and humidity. As well as vent temp.
@robertcherry4971
@robertcherry4971 3 ай бұрын
Low load ,charge is low as well I would bring sub cooling to specifications if specs are not listed bring sub cooling to 7-10 degrees .
@ironshieldheatingair5751
@ironshieldheatingair5751 3 ай бұрын
The charge was spot on. It was definitely a low load issue 👍
@robertcherry4971
@robertcherry4971 3 ай бұрын
@@ironshieldheatingair5751 disagree with you charge is low. Superheated is to high at them conditions and subcooling is low . That tells us to little refigerant on low side to little on high side what does that indicate? Sh 20 Sc 3-4 to low .
@brianwhite167
@brianwhite167 2 ай бұрын
​@@robertcherry4971 That is what I am saying as well. That unit is low on refrigerant. If your refrigerant is superheating 20° with a low inside temperature you're evaporators clearly starving for refrigerant, and I can't speak for anybody else but i have never seen a recommended subcooling of 3. The general guideline I have always been taught was subcooling between 7 to 12 degrees, and from experience I can say manufacturers want their equipment to be in a range of 10 to 13. Also it is entirely too cold outside for him to be adjusting refrigerant. His liquid saturation is 100° so his outdoor dry bulb temperature is probably between 70-75 degrees.
@NikkoApril
@NikkoApril 3 ай бұрын
That is a little low as well. Txv? You’re lsat is like 3 degrees above outdoor. Should be 15 minimum 8 degrees subcool. You’re VSAT will go up and low side. The indoor temp of 78 will not effect that maybe 65-68 degrees indoor would
@ironshieldheatingair5751
@ironshieldheatingair5751 3 ай бұрын
Txv indoor and the charge was spot on per charging table. Every system has a different subcool and superheat target. The indoor temp was 67 degrees and the return air temp was even colder due to a portable unit installed next to the return air. The homeowner wanted it cold. I see you didn’t watch the whole video based off of your comment 👍
@Sal-jy7sw
@Sal-jy7sw 3 ай бұрын
looks like an airflow issue possible low heat load, you will be returning to address ice up coil good luck
@emeliojuarez3617
@emeliojuarez3617 3 ай бұрын
Are you looking for a leak or just charging. I took a class once and he said never be Dr. Recharge if your low look for the leak.
@ironshieldheatingair5751
@ironshieldheatingair5751 3 ай бұрын
Just charging it. The system wasn't leaking. I was making adjustments to the charge
@Samlol23_drrich
@Samlol23_drrich 3 ай бұрын
Very good video. Thank you.
@ironshieldheatingair5751
@ironshieldheatingair5751 3 ай бұрын
Your welcome 🤝🏻
@seangriffon6502
@seangriffon6502 3 ай бұрын
How cold is he trying to keep the inside? Someone told me that your central unit can only cool 10 to 15 degrees below the outside temp. I dont know how true this holds. I prefer window units i can get my bedroom about 68 degrees on a 100 degree day. But my bedroom is on the north side. He needs a freeze protector stat on the evap coil. Its wired in with the 24 volt contactor in the outdoor unit so if it detects freezeing conditions on the evaporator it will shut off the condensor blower will run till frost melts, and outdoor unit will restart again. I worked on a trane unit that was set up as a low ambient unit to cool a server room, and it had a freeze protect device on the evap coil.
@ericnewton5720
@ericnewton5720 3 ай бұрын
I’m anxious to see the answer to this. Just installed $15k system sep-2023 that can’t cool my house below 82 degrees when it was 98 outside. Feeling pretty scammed.
@ironshieldheatingair5751
@ironshieldheatingair5751 3 ай бұрын
A freeze stat should be standard on all systems in my opinion. But a properly sized air conditioner with proper ventilation in the attic space where the duct work is located should keep the home 20-25 degrees cooler than the outside temperature. A slightly oversized 2 stage system is the way to go in Florida in my opinion so it can ramp up on the hot days and ramp down on the mild days 👍
@Bacongrease00
@Bacongrease00 3 ай бұрын
I’m in mesa az. When it’s 115f out I can keep it 72f if I want to watch that power meter spin. I also have 8 tons of cooling on a 2800 sq ft home.
@yogibare7207
@yogibare7207 3 ай бұрын
Man You Ain’t Lying About Them Window Units Especially If you Close The Door To That Room 🙌🏾
@JR-mj8kh
@JR-mj8kh 3 ай бұрын
⁠@@ericnewton5720that’s 100% on how the install was performed. Something’s definitely going on because I’m a hvac tech myself and I have a 20 year old r-22 system that works perfect on 95 degree days . Something’s going on there w
@rokashi2104
@rokashi2104 3 ай бұрын
You will go back .... to adress air flow
@ironshieldheatingair5751
@ironshieldheatingair5751 3 ай бұрын
No, I wrapped it up. The homeowner had a portable unit sitting in front of the air return causing a really low return air temp. The home was 65 but the return air temp was 57 degrees. Causing a freezing temperature evaporator coil. The filter was clean and the static pressure was .06 😎
@andymasiddo8180
@andymasiddo8180 3 ай бұрын
Excellent explanation on troubleshooting!!! Loved it, man!
@ironshieldheatingair5751
@ironshieldheatingair5751 3 ай бұрын
Thanks Andy! Glad you loved it
@NewJackChris
@NewJackChris 3 ай бұрын
This is a horrible install
@ironshieldheatingair5751
@ironshieldheatingair5751 3 ай бұрын
The builder loves it, the new homeowners, and the inspectors. There's nothing wrong with this install buddy. Thanks for watching
@justynnoss2786
@justynnoss2786 20 күн бұрын
The hard start installed on a brand new system? 😭 and why is it upside down
@wauncarlo378
@wauncarlo378 3 ай бұрын
0 DOLLA... MAKE YOU HOLLAAA!!!
@wauncarlo378
@wauncarlo378 3 ай бұрын
Nice work!
@ironshieldheatingair5751
@ironshieldheatingair5751 3 ай бұрын
Thanks!
@chuckhanshaw1638
@chuckhanshaw1638 3 ай бұрын
All johnson control brands have become total junk...80% have warranty issues.
@ironshieldheatingair5751
@ironshieldheatingair5751 3 ай бұрын
I agree Chuck!
@frankjackson1918
@frankjackson1918 3 ай бұрын
Did you measure indoor airflow with a manometer? Kind of looked like low indoor airflow to me.
@rpsmith
@rpsmith 3 ай бұрын
Just what I was thinking.
@ironshieldheatingair5751
@ironshieldheatingair5751 3 ай бұрын
The issue ended up being that he had a portable unit sitting in front of the air return so the return air temp was 57 degrees 😂. The guy was from Wisconsin and wanted it freezing cold in the home. I like my house cold but this guy was on a different level. The air flow was spot on. The static pressure across .06
@Balticblue93
@Balticblue93 3 ай бұрын
@@ironshieldheatingair5751 I have never seen or ever heard of static pressure reading of .06 in my entire career. That is basically no static pressure at all. .6 I can buy and see all the time, but .1 or .2 is hard enough to achieve with the newest systems. The rest of the video I am onboard with. In Colorado, everything is de-rated, so we have to adjust charges differently. But that SP is hard to believe.
@ironshieldheatingair5751
@ironshieldheatingair5751 3 ай бұрын
@@Balticblue93 nice catch! 😂 I meant to put .6 🙌🏼
@ironshieldheatingair5751
@ironshieldheatingair5751 3 ай бұрын
@@Balticblue93 I’ll be in Colorado next summer. Looking forward to it.
@ATAKace1
@ATAKace1 3 ай бұрын
cnt terminal got me laughing a bit there 🤣
@ironshieldheatingair5751
@ironshieldheatingair5751 3 ай бұрын
Hahahaha!
@thesilentonevictor
@thesilentonevictor 3 ай бұрын
Good job Victor
@ironshieldheatingair5751
@ironshieldheatingair5751 3 ай бұрын
Thank you sir!
@Brian_541
@Brian_541 4 ай бұрын
Long time no see Victor. Good to see you again man!
@ironshieldheatingair5751
@ironshieldheatingair5751 4 ай бұрын
Yessir, been building and haven’t had the time to make any videos in a while. I realized that my techs could use these for training so I’ll be making videos and posting them here. Thanks brother, glad to be back
@VictorofHVAC
@VictorofHVAC 4 ай бұрын
Hey that Guy looks familiar!
@ComfortMedicACHeatingServices
@ComfortMedicACHeatingServices 4 ай бұрын
Thanks for sharing brotha I’m out in the big easy doing hvac service work for my self also I agree with u to check super heat sub cool
@ironshieldheatingair5751
@ironshieldheatingair5751 4 ай бұрын
You’re welcome, glad you enjoyed the video. Stay cool out there 👍🏼 it’s been hot lately 🥵
@thesilentonevictor
@thesilentonevictor 4 ай бұрын
What's up Victor long time lol
@ironshieldheatingair5751
@ironshieldheatingair5751 3 ай бұрын
Hey Victor! I have been slammed with building one of the best HVAC companies in the area. Hard work but I'm starting to see the light. Hope all is well with you my man!
@Qualitytek414
@Qualitytek414 7 ай бұрын
Damn thought id never see another victor video glad to see you taking care of business hopefully see more vids comin soon
@ironshieldheatingair5751
@ironshieldheatingair5751 7 ай бұрын
Definitely more videos coming soon. Now that I have the team aligned, I can focus on making content and promoting. Thanks for watching and supporting 🤝
@thesilentonevictor
@thesilentonevictor 7 ай бұрын
What's up Victor long time
@ironshieldheatingair5751
@ironshieldheatingair5751 7 ай бұрын
Hey there! Yessir, I’ve been swamped lately but I’m doing great, hope the same for you Victor
@thesilentonevictor
@thesilentonevictor 7 ай бұрын
@@ironshieldheatingair5751 good to hear from you happy that business is good on your end I am there taking it one day at a time as a hospital tech HVAC-R
@richlikeg3722
@richlikeg3722 Жыл бұрын
Like how the builder actually incorporated for the air handler for once instead of putting in the attic
@ironshieldheatingair5751
@ironshieldheatingair5751 7 ай бұрын
We do a bunch of homes with the cutout in the garage like that. There’s only one builder that I know of that still puts them in the attic
@richlikeg3722
@richlikeg3722 Жыл бұрын
So did you just pump it up and go? With all that caulking, somone must had nicked the line when pulling it through
@ironshieldheatingair5751
@ironshieldheatingair5751 7 ай бұрын
We ran a new copper line through the attic
@thesilentonevictor
@thesilentonevictor Жыл бұрын
Victor at it again
@ironshieldheatingair5751
@ironshieldheatingair5751 Жыл бұрын
Watsup Vic! How you been?
@thesilentonevictor
@thesilentonevictor Жыл бұрын
@@ironshieldheatingair5751 I just came back from vacation I was out for a month
@ironshieldheatingair5751
@ironshieldheatingair5751 Жыл бұрын
@@thesilentonevictor nice! I'm sure it was much needed
@thesilentonevictor
@thesilentonevictor Жыл бұрын
Great job victor on this one
@ironshieldheatingair5751
@ironshieldheatingair5751 Жыл бұрын
Thank you sir 😁
@realSamAndrew
@realSamAndrew Жыл бұрын
Did you change channels? If so, why? Also, how did you come up with the name iron shield? Just curious since it doesn't sound like typical HVAC names
@ironshieldheatingair5751
@ironshieldheatingair5751 7 ай бұрын
I changed channels because I want to support my business and I’m no longer out there running service calls to support the channel. I will be making more videos but I want it to reflect my business and amazing team, not me. That’s the best part. Iron shield heating & air is unique and my sister company is iron shield electrical, which was already established so I rolled with that name for brand awareness. I now have iron shield plumbing in the works and who knows, might start iron shield insulation soon. I appreciate you following along and I’ll be making more content soon that’s even better 🤝 hope you enjoyed Victor of Hvac 😎