DuraWater, By Aplus Water LLC
0:40
2 жыл бұрын
Fleck 9100 SXT Installation Video
21:24
DuraWater Line Water Softeners
4:00
7 жыл бұрын
Duraline Well Water Softener
1:48
7 жыл бұрын
Air Injection Iron Eater Video
1:44
7 жыл бұрын
Iron Blaster
2:17
7 жыл бұрын
Air Injection Iron Eater
12:26
7 жыл бұрын
DuraWater City Softener
2:29
7 жыл бұрын
DuraWater Line Water Softeners
3:44
7 жыл бұрын
Пікірлер
@alfredofranco9719
@alfredofranco9719 5 күн бұрын
Thank you sir 👌
@emfarfan
@emfarfan 9 күн бұрын
Thank you for a very simple procedure to follow! Does the 5600 have memory of the settings that will persist across a power outage of several hours? It seems that it does except in my case the brine fill number was off for my tank, tia!
@ivandimeo4840
@ivandimeo4840 24 күн бұрын
I programmed the water softener, I chose gallons as the unit of measurement, at the end of the programming is the value on the water consumption display gallons or liters? Thanks for the explanations.
@AplusWaterLLC
@AplusWaterLLC 22 күн бұрын
With the Display Format set to Gal, the number of the consumption is in gallons! Hope that helps!
@ivandimeo4840
@ivandimeo4840 22 күн бұрын
​@@AplusWaterLLC thank you so much!
@allenpartyof6
@allenpartyof6 26 күн бұрын
My Iron test reads 0.03 mg/l so do i add 15 to the H parameter (.03x5) or is 0.03 not even considered a 1. TIA
@eddiecedillos8417
@eddiecedillos8417 Ай бұрын
Thank you very much. Amazing video
@dnycrane
@dnycrane Ай бұрын
What setting can i adjust that has the most effect on softness, I want the water softer than the "normal" settings for a 48K capacity system.
@taylorflowers4598
@taylorflowers4598 2 ай бұрын
I have a 5600sxt. Flow rate was 0.0 per diagnostic check, so I just cleaned out the control valve assembly and made sure there were no built-up iron deposits remaining. I put it back together and, still, flow rate is 0.0. When I turn a faucet on, the flow indicator (water droplet icon) does not show up, and the "gallons remaining" number does not change. I can successfully run a regeneration cycle and everything works (brine draw, fill, etc., with a good float assembly). What is my next step? I think the control valve assembly is in good shape.
@stierbyku4922
@stierbyku4922 2 ай бұрын
Good day, I have a problem with my Fleck 5600sxt, it does not count water consumption and therefore cleaning does not start. What could it be? Have you encountered such a problem? I would be grateful for any information. Best regards, Marek
@Nena800
@Nena800 2 ай бұрын
DIYer here...Thank you for these videos!!!
@holdentasillo588
@holdentasillo588 2 ай бұрын
Will this Fleck 5600 SXT Air Injection Iron Eater Filter work for removing colloidal iron?
@gauravagru1
@gauravagru1 2 ай бұрын
Do you recommend adding lubricants to seals and spacers ?
@balaspbponnusamy8592
@balaspbponnusamy8592 3 ай бұрын
Excellent video 👍👍👍
@vanessarizio8414
@vanessarizio8414 3 ай бұрын
Our instructions say to connect the incoming water to the DOWNFLOW inlet.
@CD318
@CD318 3 ай бұрын
Good job
@pefferie
@pefferie 4 ай бұрын
Wgere can I buy these 1" supply hoses?
@latourbrian
@latourbrian 4 ай бұрын
Thanks for posting these videos, it taught me a lot. But... I followed all the steps in both videos and no luck. When i had the drain flow button out, I did get draw. I changed the brine valve for like $15, still no luck. All the parts in the backwash injector assembly were very clean even when i first opened it up. So I ended up buying the main piston assembly with seals and spacers for $70. I honestly didn't think it would work. It did. I have brine draw again. So if you try all the tips and still get water flowing out to the salt tank during BD, as a last resort I'd suggest a new main valve. BTW, my main piston a green top and the one i bought from amz was white... it worked fine. Maybe i'm missing something there, but it just seems ok.
@destroyingtheworksofthedev9349
@destroyingtheworksofthedev9349 5 ай бұрын
Hi my brine tank seems to be low as in the level. For instance the level is sitting like 2 feet below the release valve, is this normal?
@rodneysanborn3183
@rodneysanborn3183 5 ай бұрын
On the turbine, / paddle setting, I have neither, I just bought the 5600, I have no other attachments, what would my setting be? And are any other settings I should know?
@MadisonandAustinVanderveen
@MadisonandAustinVanderveen 3 ай бұрын
Same here. I never received a meter?
@blockfather1375
@blockfather1375 6 ай бұрын
I followed these settings but my air injection head unit still spits water out of the air port before RR and then at the end before brine fill. brine fill is set to OFF and I now have all the settings the same as described in the video. any thoughts on why it insists on spewing out water for a few seconds at the start and maybe 15-30 seconds at the end of the cycle? thanks
@RomanKocherovsky
@RomanKocherovsky 6 ай бұрын
is the guy doing the demo Marc Ribillet 😁. Also, very helpful video.
@stephensaenz463
@stephensaenz463 6 ай бұрын
How do you turn it on
@trevorrussell7679
@trevorrussell7679 6 ай бұрын
Maybe a silly question, but is it possible to back-flush/drain back into the well itself? My system is not near my septic and I know it’d be putting debris back down, but didn’t know if it would be rough to filter back through or not.. also how many gallons does the backflush typically use?
@wsurfer2147
@wsurfer2147 6 ай бұрын
Thanks for the video, What to do if the controll valve electronic no longer function (broken) ?
@AplusWaterLLC
@AplusWaterLLC 6 ай бұрын
If the system is unable to be regenerated, you'll need to depressurize the entire home. To do this, you'll want to shut the main water off and run a faucet until there is no water left. Hope that helps! -Aplus Water
@wsurfer2147
@wsurfer2147 6 ай бұрын
@@AplusWaterLLC Thank you for the info. I have another question. My 5600 sxt screen is dead, I change the 24vac power supply but that didn't help. Is the controll board bad?
@AplusWaterLLC
@AplusWaterLLC 6 ай бұрын
@@wsurfer2147 If replacing the transformer did not help, there is a good chance that the circuit board is to blame for no power to the valve. (assuming the outlet that the system is plugged into is working properly)- Aplus Water
@wsurfer2147
@wsurfer2147 6 ай бұрын
@@AplusWaterLLC Thank you. I replaced the transformer but it also died. Because i think there is a short somewhere in the controll head. The original tramsformer died. I did check the outlet by plugging a light and it was fine.
@Partsunknown426
@Partsunknown426 6 ай бұрын
Is this a 9 x 48 tank? is that why a 40 min air draw? plus does the air draw push most of the water out of the tank in that time?
@pkdude5334
@pkdude5334 6 ай бұрын
should the softener or AIO be regenerated first? does it matter?
@AplusWaterLLC
@AplusWaterLLC 6 ай бұрын
Hi, It does not matter at all which one regenerates first, they just cannot regenerate at the same time! -Aplus Water
@stapler40
@stapler40 7 ай бұрын
What is the lifespan of the 5600sxt? I ask because I currently have one installed in my home, which is about 15 years old. So, how does one determine the condition of the unit. I've never had any errors with the unit in 15 years, but is it time to swap out for a new 5600sxt. If I do decide to swap out, should I buy the entire device, or do you think I would only need a tank? Thank you for any help you can provide.
@AplusWaterLLC
@AplusWaterLLC 6 ай бұрын
Hi! It really depends on water quality and water usage for how long a system may last. The only way to know it is time for a new one is when the old one goes out on you. If your current system is running fine, there's no reason to upgrade just yet. Whether you buy a complete new system or just new resin is up to you! There are benefits to both, such as new warranties on a new system or saving on cost by doing just resin. Feel free to give us a call and pick our brains regarding your situation. We are happy to help!- Aplus Water
@logikalx
@logikalx 7 ай бұрын
Thanks for the video, I saw my tank was full and just hit regen in panic. So that did nothing but while it was trying to do its thing i was able to pull the float system and syphon almost all of the water from the brine tank, so even if its not fixed at least it wont overflow before I can get a technician out!
@duckhunter8387
@duckhunter8387 8 ай бұрын
Well done!
@freddyrojas6956
@freddyrojas6956 8 ай бұрын
Any chance to get a model 9500 programming help
@felixandanavelazquez9245
@felixandanavelazquez9245 8 ай бұрын
I have the same unit that the clock is set to 24 hours instead of 12. How I can change to 12 hours.( I can not see the pm icon)
@AplusWaterLLC
@AplusWaterLLC 8 ай бұрын
It sounds like the display format on your system is set to Liters instead of gallons. You will just set the clock to 12:01 and hold both arrow buttons down until DF LTR pops up. Change this setting to DF GAL and the clock will read in gallons and the 12 hour clock. Give us a call if you're still having issues!- Aplus Water
@johna.ludwig2311
@johna.ludwig2311 8 ай бұрын
First of all, thank you for making it clear about the 12:01.......I tried with the correct time of day with no success. The rest is programmed ok but how do you program the NUMBER OF GALLONS BEFORE REGENERATON? Mine just has four dashes. - - - - What does that mean and how do I program it?
@AplusWaterLLC
@AplusWaterLLC 8 ай бұрын
The number of gallons should automatically be configured based on the capacity of the system, the hardness of the system, and the reserve setting. If you have the hardness cranked way up and the capacity set way low, you will experience the dashes. I would double check that your settings are set accurately. If you are still struggling, give us a call! - Aplus Water
@zachhopkins9719
@zachhopkins9719 8 ай бұрын
Thank you very much!!! Took a while to find your video. Everyone else was telling me to flow out lines that are probably blocked. Did two regular regeneration without using a shop vac to suck out the water to be below the float. I have three tanks total, two control heads but I believe the one that looks most similar to yours is a double unit and step 2 is brine/rinse. Jumped to that and see movement down in the brine well which I wasn’t getting before. Might not be fixed but thanks for providing an alternative troubleshooting method that sounds like I should have tried first if it’s that common
@HooverFamily-nn8di
@HooverFamily-nn8di 8 ай бұрын
Can you replace the manual valve control with a digital one?
@AplusWaterLLC
@AplusWaterLLC 8 ай бұрын
Hi! Yes! Most of the time, replacing a mechanical valve with a digital valve is an easy, direct swap. - Aplus Water
@ajeshrama2419
@ajeshrama2419 8 ай бұрын
During the last four years, we have had no problems with the same model, but now we are experiencing continuous drain, and softener tank is completely empty, would it be possible for you to suggest any solutions?
@AplusWaterLLC
@AplusWaterLLC 8 ай бұрын
Hi! Continuous leak to the drain is usually a red flag that the main piston seals of the valve are either worn down or compromised by debris. Once you replace/clean those seals, you should be back to normal operation. Hope that helps! - Aplus Water
@ajeshrama2419
@ajeshrama2419 8 ай бұрын
@@AplusWaterLLC thank you brother
@k50159
@k50159 9 ай бұрын
Much appreciated
@jimrudenberg6099
@jimrudenberg6099 9 ай бұрын
Thanks, This worked well! Very thankful.
@joeala762
@joeala762 9 ай бұрын
What if don't know how hard your water is?
@matjusz8985
@matjusz8985 9 ай бұрын
Can I adjust the hardness later on?
@AplusWaterLLC
@AplusWaterLLC 9 ай бұрын
Hi! You can always go back and adjust the hardness in the programming!
@3rdBNDeltaCo
@3rdBNDeltaCo 9 ай бұрын
What size are the O-rings?
@robertmartin4780
@robertmartin4780 9 ай бұрын
Please, this is a good video telling me nearly all I need to know. But what precisely should I see inside the tank before, during and after changing the media. If the time has come to change and I shine my light will I see a residual level of calcite or am I seeing internal tank structure? What am I actually seeing when the tank appears to have some calcite in it up to about a foot from the bottom? How much water should I remove before adding more calcite? Just above the shadow of existing calcite? Fill with new calcite to within six inches from top of tank? Thanks much. I'm about to service my filter in my crawl space and want to be assured of the proper procedure.
@FiveMinutesWithATechnician
@FiveMinutesWithATechnician 10 ай бұрын
Why do you not recommend using the smaller mesh screen in the brine line kit? 9:31
@AplusWaterLLC
@AplusWaterLLC 10 ай бұрын
Great question! We notice they tend to get clogged pretty easily causing a loss of pressure through the system. It just ends up being a hassle to clean it out every so often rather than just leaving it out. Hope that helps!!- Aplus Water
@aquariuswithfire
@aquariuswithfire 10 ай бұрын
Do these units require periodic maintenance and is so how often? TY Great Vid BTW!
@AplusWaterLLC
@AplusWaterLLC 10 ай бұрын
Hi! We recommend periodically cleaning the injectors and the drain line flow control washers. If you have iron in the water, we recommend this about once a year or so. We have videos on how to access these as well on our channel! Glad to hear you're enjoying the videos! Thanks! -Aplus Water
@christophe3281
@christophe3281 10 ай бұрын
Is the turbine valve necessary if it’s an AIO that recharges every 3 days anyway?
@AplusWaterLLC
@AplusWaterLLC 10 ай бұрын
Hi! An air injection system will not use a meter. It runs strictly on the day override setting. Hope that helps! -Aplus Water
@christophe3281
@christophe3281 10 ай бұрын
@@AplusWaterLLC thanks for the reply!
@snipex111
@snipex111 10 ай бұрын
Should i depressurize and bypass when going on vacation?? Say 7 days ?
@AplusWaterLLC
@AplusWaterLLC 10 ай бұрын
Hi, If you're only going to be gone for a while, just unplug the system from the outlet. This will prevent it from regenerating while you're gone. No need to depressurize or bypass the system! Whenever you get back, you'll just plug the valve back in and reset the time of day. The programming will remain indefinitely for you. Hope that helps! - Aplus Water
@snipex111
@snipex111 10 ай бұрын
Yes thank you
@paulh6591
@paulh6591 10 ай бұрын
Does Fleck sell a wrench to remove the head assembly? I have an oler model, and even after releasing pressure, it's on too tight to unscrew by hand.
@AplusWaterLLC
@AplusWaterLLC 10 ай бұрын
Unfortunately there are no wrenches to remove the valve. It sounds like yours may have been overtightened when it was installed. Most of the time, the valve unscrews fairly easily by hand. I would say keep trying your best, but be very careful not to damage the threads of the tank! If the threads are damaged you'll need a whole new tank. If you end up installing a new valve (or reinstalling your old one), be sure to only put the valve on until it is snug and secure. Also, be sure to not use any sort of pipe dope or teflon tape on this connection. A little lubricant and some elbow grease should get the valve on just tight enough to have a secure connection without making it impossible to remove the valve in the future.- Aplus Water
@paulh6591
@paulh6591 10 ай бұрын
@@AplusWaterLLC Thanks- maybe I'll use a strap wrench. That Fleck 5600 SXT digital head you have here... would it be a direct swap for my old motor-drived 14-day Fleck brine unit unit, so I can keep the old tank, which still looks good? The old Fleck had developed a hairline weep leak, I'm tired of hearing the little clock driver motor, and the unit hasn't been serviced for years so I need new beads anyway. While I'm at it I'd like to update the head unit. My other option would be to not use a softener- I've had this one on bypass for the last few months, now I'm toying with discarding/gifting it or fixing it up.
@pefferie
@pefferie 4 ай бұрын
I stick a scrap of copper pipe into an inlet port for leverage
@christophe3281
@christophe3281 10 ай бұрын
Are the valve heads interchangeable for a softener to an aio? For example, could you use the 5600sxt softener valve for an aio if you reconfigure the program and add a check valve where the brine draw would connect?
@AplusWaterLLC
@AplusWaterLLC 10 ай бұрын
Hi, The valves are built very similarly, but to convert the softener valve to an air injection valve, you would need to reconfigure the programming, add a check valve where the brine line connection is, replace the flow controls to suit the difference between the softener resin and the filter media, and add a check valve to the inlet side of the valve (to make sure your air pocket does not escape). A lot of times, it ends up being fairly close (if not better) in price to buy a brand new system than try to convert everything over. Hope that helps!- Aplus Water
@christophe3281
@christophe3281 11 ай бұрын
Is this the same type of valve that’s used for an air injector for iron filters as well as softeners?
@scottcarter9975
@scottcarter9975 11 ай бұрын
I am so confused! On the hardness setting. Our hardness is 2.5 grains per gallon. I understand that three is the maximum you want. Our iron is 0.15 ppm. I understand that 0.3 is the maximum healthy. These numbers are so different from your description. Am I misunderstanding something? Thanks.
@JamesDThomas1981
@JamesDThomas1981 11 ай бұрын
Excellent video. I had to disconnect my water softener so I can get my garage floors painted. So when I went to go put the water softener back in I need a directions on how to set up. The best I've seen thus far.
@MarkPeterson-u2x
@MarkPeterson-u2x Жыл бұрын
Had the 64,000 unit, it has run 2 cycles since it was installed about 3-4 weeks ago, last cycle a couple days ago. Level fills to about 1100, now down to 90 in 2 days, also says "rc" with blinking water faucet, what's going on? Of course always on weekend when you can't call anyone.
@AplusWaterLLC
@AplusWaterLLC Жыл бұрын
Hi, "rc" stands for reserve capacity. This means you are currently using the reserve of soft water that the system has built in through the programming. This is just to ensure you do not run out of soft water halfway through the day. When you see "rc" a regeneration gets queued up to occur later that night, hence why you see the blinking water faucet. 1100 gallons down to 90 in 2 days is really quick. This could be correct if there are a lot of people using the water. If you haven't already, though, I would double check that the programmed settings are correct and your hardness number is accurate. If everything looks accurate and you don't have a ton of water usage, check for leaks throughout the home (possibly a leaky toilet or something like that). We are in the office Monday - Friday 9am-4pm CST. Give us a call if you are still having issues! - Aplus Water