Why Does Specific Information Matter?
3:12
How We Fire Test Pipework
2:51
2 ай бұрын
MEP Considerations - Part Two
16:46
What Is an Annulus?
3:42
4 ай бұрын
MEP Considerations - Part One
19:15
Пікірлер
@HassanAhmed-pu4wd
@HassanAhmed-pu4wd 5 күн бұрын
Yet another great episode!
@FirestoppingSolutions
@FirestoppingSolutions 5 күн бұрын
Thanks Hassan!
@waynebarrow7260
@waynebarrow7260 12 күн бұрын
I deeply appreciate your focus on early engagement in firestopping, how strongly you have carried the skills, competency & behaviors message forward, and the "Because it's your job" campaign. Well done to you all!
@FirestoppingSolutions
@FirestoppingSolutions 11 күн бұрын
Thanks for your support Wayne!
@alexorza83
@alexorza83 27 күн бұрын
WELL DONE GUYS
@FirestoppingSolutions
@FirestoppingSolutions 21 күн бұрын
Thank you!
@davidbathe4108
@davidbathe4108 Ай бұрын
Thank you These videos are so useful
@FirestoppingSolutions
@FirestoppingSolutions Ай бұрын
Thank you David!
@davidbathe4108
@davidbathe4108 Ай бұрын
Brilliant Hassan does really have a clear compass on his development with in other industries
@davidbathe4108
@davidbathe4108 5 күн бұрын
I really do need to speak to one of your team for guidance with in the industry
@davidbathe4108
@davidbathe4108 Ай бұрын
That was brilliant gents Thank you I was glued to your conversation My role with in my company has changed and I am getting more and more involved with the fire stopping side of the company I have so much more to learn and tbh don’t feel confident speaking about what we are installing Could I contact either of you guys directly Many thanks
@FirestoppingSolutions
@FirestoppingSolutions Ай бұрын
Hi David - thanks for your feedback. Certainly, we'd be more than happy to help. If you could contact us at [email protected].
@davidbathe4108
@davidbathe4108 Ай бұрын
@@FirestoppingSolutions do you have a e mail that I can contact someone on
@tonyprice3944
@tonyprice3944 Ай бұрын
What fixings are you using … we have to use 8mm mushrooms when fixing to concrete … fire rated screws would defo save my arm from hammering in mushrooms all day
@FirestoppingSolutions
@FirestoppingSolutions Ай бұрын
Hi Tony, thanks for your question. Please refer to pages 4, 5, 6, & 7 of detail QB-CF150-P-06: quelfire.co.uk/wp-content/uploads/QB-CF150-D-06-Plastic-pipe-penetrating-a-rigid-floor-QuelCoil.pdf.
@shyabudheensurur1127
@shyabudheensurur1127 Ай бұрын
Is ter any vacancy for ti's job
@stefanescuradu9649
@stefanescuradu9649 3 ай бұрын
It would be great if the services would be like this on the actual site as well but what you find in there sometimes is terryfing.
@HassanAhmed-pu4wd
@HassanAhmed-pu4wd 3 ай бұрын
Yet another excellent presentation with loads of great information!
@FirestoppingSolutions
@FirestoppingSolutions 3 ай бұрын
Thanks Hassan!
@AdamP-le2we
@AdamP-le2we 4 ай бұрын
UKPN doesn't accept this detail due too it hasn't got any structural element' if services fall the fire batt would fail.
@ingusandersons3800
@ingusandersons3800 4 ай бұрын
Service supports should be 100 - 400mm of firewalls, 400mm or less means that they can install it tight to wall and when you have to istall face fit batt service support is in the way.
@jimmccorry7193
@jimmccorry7193 4 ай бұрын
Very informative as usual
@FirestoppingSolutions
@FirestoppingSolutions 4 ай бұрын
Thank you for your feedback!
@user-md8mi6kv5m
@user-md8mi6kv5m 4 ай бұрын
you have examples how do this?
@dayarchitectural3843
@dayarchitectural3843 4 ай бұрын
Another great episode!
@FirestoppingSolutions
@FirestoppingSolutions 4 ай бұрын
Thank you!
@arekarek1991
@arekarek1991 4 ай бұрын
Uk is so backwards to compare to Europe.
@yeehawongi4920
@yeehawongi4920 5 ай бұрын
Great stuff! All of the metal pipes need to be wrapped with insulation? Why not for those metal cables on cable tray 8:20?
@waynebarrow7260
@waynebarrow7260 5 ай бұрын
Well done Quelfire! Genuinely appreciate your efforts to educate and that you are taking such a practical and full scope look at passive fire protection, not just promoting your products. I can see where the Glenfell tragedy has driven much discussion of competency and Dame Judith Hackitt's statement of "Competency can no longer be assumed", but it is great that you are pushing that truth to your field and customers. I especially appreciate the comments about Engineering Judgments and Mandy's comments about NOT certifying "solutions" that have not been tested or that have no test data to support them.
@user-md8mi6kv5m
@user-md8mi6kv5m 5 ай бұрын
great company)
@Bh1979.
@Bh1979. 5 ай бұрын
Can't fault your company for testing all sorts of details, my issue is why is the fire batt so brittle?
@sudoku1980
@sudoku1980 8 ай бұрын
Great presentation. But I don't think it was a sleeved gas pipe.
@arturasmarchelo4696
@arturasmarchelo4696 9 ай бұрын
Its not a fierstopping, its decorative hp mastic applying, because mastic should be in all depth of fierbatt😢
@FirestoppingSolutions
@FirestoppingSolutions 9 ай бұрын
Hello, thanks for your comment. QuelStop HPE Sealant should be installed as per our fire test evidence and for this application it is a 25mm depth, as shown on detail QB-FW100-D-02.
@davidiarus
@davidiarus 3 ай бұрын
​@@FirestoppingSolutionswhat for hp onto armoured cables ?
@martinbainbridge7355
@martinbainbridge7355 10 ай бұрын
Very informative thank you. I am still not clear if hospitals and residential care homes over 7-floor or 18-metres only, will in the future fall into the higher risk category. Or, if the intention is for all hospitals and care homes to be considered higher risk?
@alecpurdie7181
@alecpurdie7181 10 ай бұрын
If you go to this Gov.uk page it provides the current criteria: www.gov.uk/guidance/criteria-for-determining-whether-a-new-building-that-is-being-designed-and-constructed-is-a-higher-risk-building#:~:text=For%20the%20design%20and%20construction%20part%20of%20the%20regime%2C%20higher,have%20at%20least%207%20storeys. You will see this paragraph: For the design and construction part of the regime, higher-risk buildings are defined as buildings with at least two residential units, care homes, and hospitals which are at least 18 metres in height or have at least 7 storeys.
@user-md8mi6kv5m
@user-md8mi6kv5m 10 ай бұрын
Hello,how you testing your details?)you have video?)
@HassanAhmed-pu4wd
@HassanAhmed-pu4wd 11 ай бұрын
Hi Glenn. Great presentation, thanks. Question regarding the one sided batt application, us it tested from both sides or just the application side? Thanks.
@FirestoppingSolutions
@FirestoppingSolutions 11 ай бұрын
Hello Hassan, thank you for your feedback and question. Our single-side access details are always tested from both sides to replicate a worst-case scenario. If you would like more information on these details and the testing, please contact [email protected].
@garnolan34
@garnolan34 Жыл бұрын
Great video again Glenn. Thanks for the information. Garrett
@BarryDean007
@BarryDean007 Жыл бұрын
Will this be good study for Level 2?
@FirestoppingSolutions
@FirestoppingSolutions 11 ай бұрын
Hi Barry, thanks for your question. It most certainly has some useful content for Level 2. Episode 6 might be a good watch as it specifically delves into Level 2 & 3, discussing the exams: kzbin.info/www/bejne/b5XVlKRnjsx9gM0si=c4YH8r5mtP0_T6ca
@bardechampagne7710
@bardechampagne7710 Жыл бұрын
😕 Promo'SM
@liamwilson5830
@liamwilson5830 Жыл бұрын
Doesn’t hp corrode cvpc?
@FirestoppingSolutions
@FirestoppingSolutions Жыл бұрын
Hello Liam, thanks for your question. Certain products can be non-chemically compatible with CPVC pipes. Only approved HPE sealants such as the QuelStop HPE Sealant, which has been approved by both Lubrizol and Spears for use on their CPVC systems, can be used. For more information, read this knowledge hub piece: quelfire.co.uk/knowledge-advice/considerations-when-firestopping-cpvc-pipes/ or contact us at [email protected].
@ytshorts-nx8vb
@ytshorts-nx8vb Жыл бұрын
That one is new to me
@eddymk8381
@eddymk8381 Жыл бұрын
Is it true that before applying HPE on it, we have to use reflective tape on the pipe?
@FirestoppingSolutions
@FirestoppingSolutions Жыл бұрын
Hello, thanks for your question. In some cases, reflective tape is required when the sealant is not approved. However, this is not the case for our QuelStop HPE Sealant as it has been approved by the two main manufacturers of CPVC pipes. Read our short article for more information: quelfire.co.uk/knowledge-advice/considerations-when-firestopping-cpvc-pipes/ If you do have any more questions, please don't hesitate to email us at [email protected].
@waynelister1285
@waynelister1285 Жыл бұрын
He'll happily tell you I was the best about haha
@waynelister1285
@waynelister1285 6 ай бұрын
@@MICHAEL-wg2lh what do you mean by a horse 🙄
@waynelister1285
@waynelister1285 Жыл бұрын
I used to work for these, probably the best company you can work for in passive fire protection, keiran the manager is a top man
@waynelister1285
@waynelister1285 Жыл бұрын
@@ytshorts-nx8vb keep your head down and work to the correct detail they will love ya
@cyanide170
@cyanide170 Жыл бұрын
when are M&E going to start taking into considertaion for service seperations..
@coralmorgan4005
@coralmorgan4005 Жыл бұрын
Brilliant - really useful and engaging. Well done🙂!
@FirestoppingSolutions
@FirestoppingSolutions Жыл бұрын
Thank you, Coral!
@fcbarcelona9149
@fcbarcelona9149 Жыл бұрын
Great🎉 looking foward to part 3
@FirestoppingSolutions
@FirestoppingSolutions Жыл бұрын
Thank you for your feedback. We are pleased to hear this! If you do have any questions you'd like answered then please don't hesitate to send them into [email protected] and we will be happy to help.
@HassanAhmed-pu4wd
@HassanAhmed-pu4wd Жыл бұрын
Thank you chaps - some great tips again!
@cyanide170
@cyanide170 Жыл бұрын
the man behind phone. aidan j hare
@Globaltecbrasil
@Globaltecbrasil Жыл бұрын
👏👏👏
@fcbarcelona9149
@fcbarcelona9149 Жыл бұрын
This video can help you with IFE level 3
@FirestoppingSolutions
@FirestoppingSolutions Жыл бұрын
Thank you for your feedback, we are glad you find this useful. If you have any questions you would like the team to answer regarding IFE level 3 then please email them in at [email protected] and we will be happy to help!
@davidl2229
@davidl2229 Жыл бұрын
👊 𝓹𝓻𝓸𝓶𝓸𝓼𝓶
@thomaswelbrn8522
@thomaswelbrn8522 Жыл бұрын
what EI rating do you achieve on the trunking?
@FirestoppingSolutions
@FirestoppingSolutions Жыл бұрын
Hello Thomas, thank you for your comment. We have a number of trunking details - some standard details and also some future details. Please contact our technical team regarding your application at [email protected]
@mgcservices7524
@mgcservices7524 Жыл бұрын
Hello Alec, excellent video and fantastic range of products. Can you tell me if there are any tests conducted on plastic concertina pipes, the type normally witnessed from the back of a tumble drier or bathroom/kitchen extraction fan system; would a fire collar be suitable - pipe diameter is approx 110mm.
@FirestoppingSolutions
@FirestoppingSolutions Жыл бұрын
Thanks for your feedback. We don't know of any tests carried out on the material you describe. Because the material is so thin and combustible, it is likely that it would burn quicker than the intumescent can react resulting in an integrity failure. It is always worth checking whether these ducts are actually penetrating a fire compartment wall initially. For more technical questions please send in specific details to our technical team using [email protected]
@NINJASTYLEART
@NINJASTYLEART Жыл бұрын
👍
@mattdewet6908
@mattdewet6908 Жыл бұрын
Hi Alec, this is a fantastic range, well done. Could you please give me a bit more detail about the gas pipe passing through a sleeve. it looks like QB-FW100-D-12. I have seen similar, with copper pipes passing through another copper sleeve. i never got an answer as to the reason for the sleeve and need for the gap between 2x pipes. also, is there no need for a HPE or wrap? as the yellow gas pipe would surely not be sealed off by acrylic seal alone? many thanks
@tudorcasian1812
@tudorcasian1812 2 жыл бұрын
Great video Alec, thank you
@LILAH4YOU
@LILAH4YOU 2 жыл бұрын
Super star ⭐️ xxx❤️
@kirbymoody6985
@kirbymoody6985 2 жыл бұрын
🤗 ≋p≋r≋o≋m≋o≋s≋m
@mindaugasgudas1952
@mindaugasgudas1952 2 жыл бұрын
Amazing as always! What about compound? Any showcase videos on that? Thanks in advance.
@alecpurdie7181
@alecpurdie7181 2 жыл бұрын
I will be doing a walk through of our floor application demo boards soon
@FirestoppingSolutions
@FirestoppingSolutions 2 жыл бұрын
Hi Mindaugas, thank you for your feedback. We have just uploaded a compound video, you can find it here: kzbin.info/www/bejne/fYHMmpmYh7qseqs. We hope this helps!