SOP MCP 5X00 Polarimeter - Anton Paar
13:07
Пікірлер
@Strightcontrol
@Strightcontrol 2 ай бұрын
Can you please make a video on how to perform monthly calibration on SVM 3001
@agung9745
@agung9745 5 ай бұрын
untuk uncertainty densitas nya bagaimana ya?
@mohamedthahir7496
@mohamedthahir7496 Жыл бұрын
Hi Dear, Could i use 1:1 diluted mixed acid (HCl & HNO3) for cleaning the measuring cell?. A black color solution discharged, while cleaning using 1:1 diluted mixed acid. Any advice pls.
@foxhound-0
@foxhound-0 Жыл бұрын
Hi dear, Name of the solvent using for cleaning?
@barbarapadjasek1599
@barbarapadjasek1599 Жыл бұрын
How to fix Peltier error ?
@equivaligandindonesia
@equivaligandindonesia Жыл бұрын
hi, you have to contact local Antor Paar representative. Maybe need to check
@mujtabaalyasin3853
@mujtabaalyasin3853 Жыл бұрын
Can i call ? I need help
@festusoyinbo883
@festusoyinbo883 2 жыл бұрын
Hi, nice video, we have this SVM 3001, it was working perfectly, but now its showing out of range for KV when running a sample, what could be the cause? and how can i rectify it.
@equivaligandindonesia
@equivaligandindonesia Жыл бұрын
hai, maybe the measuring cell is dirty and have to clean. You can watch video "Maintenance SVM 3001"
@muhammadnawaz136
@muhammadnawaz136 2 жыл бұрын
Hi, I am using SVM 3001, it's giving 'filling warning' error, I cleaned everything very well, but still no result. Can you please guide me about this...
@equivaligandindonesia
@equivaligandindonesia 2 жыл бұрын
Hi Nawaz, Please tell me how do you filling sample into the instrument? Usually, a filling warning appears because first when the sample is injected there is still a bubble in the syringe, second when the sample injection presses the syringe too quickly so the sample will cause bubbles in the motor in the instrument, lastly is the viscosity of the sample very thick? A filling warning appears when the sample is thick. The explanation for the filling warning itself is that the instrument detects the presence of bubbles in the sample in the instrument. The filling warning can be ignored if the sample does contain a lot of particles/bubbles that are difficult to remove or if the sample has thick characteristics.
@muhammadnawaz136
@muhammadnawaz136 2 жыл бұрын
@@equivaligandindonesia Thank you for your time, I have been using different viscometers and density meters for more than 9 years. Trust me there is no bubble at all, nor am I using very dense or very light samples. Also, I am using the appropriate syringe with very smooth injection, but still having problem of filling error. The sample doesn't have any particle or impurities. Actually I am getting a blue tick after each analysis but there is error in background too after each analysis, and it's going on addition until I clear it by myself.
@nurettinbilgili2938
@nurettinbilgili2938 2 жыл бұрын
Did u mesurre blood sample of covid19
@geetadaveeathirrakunia9902
@geetadaveeathirrakunia9902 2 жыл бұрын
anton paar re fractometer model 550 raning hindi vidio persant karay
@ouzytheoriginal
@ouzytheoriginal 2 жыл бұрын
What are the products occured after process if we pit fuel
@equivaligandindonesia
@equivaligandindonesia 2 жыл бұрын
Hello, after the process is complete, the sample remains as it was in the initial form, but because it has gone through oxidation, the sample will smell rancid and saturated
@wahyuwijanarko5131
@wahyuwijanarko5131 2 жыл бұрын
Terima kasih mas bro Barusan beli alat ini, lagi cari cari SOPnya Pas banget nemu ini
@sutrisnasandy2302
@sutrisnasandy2302 3 жыл бұрын
Beli nya dmn ya ? Harga brp
@equivaligandindonesia
@equivaligandindonesia 3 жыл бұрын
Untuk pembelian dapat mengunjungi website berikut equivaligand.com Terimakasih
@moussiferroudja8002
@moussiferroudja8002 4 жыл бұрын
Comment règle méthode baume
@equivaligandindonesia
@equivaligandindonesia 4 жыл бұрын
Hi Moussi, Pour régler la méthode Baume, il vous suffit de sélectionner la méthode puis de sélectionner Baume. Si ce n'est pas le cas, essayez de créer une nouvelle méthode et de sélectionner le paramètre baume. J'espère que ça aide.
@nabilaothman2623
@nabilaothman2623 4 жыл бұрын
Hi there. I did exactly according to steps in the video but the result i got after testing the standard is outside the range of kinematic viscosity at both 40 and 100 C. What do you think could be the reason for this and what can i do to fix this problem? Thank you!
@equivaligandindonesia
@equivaligandindonesia 4 жыл бұрын
Hi Nabila, May I ask first Is your SVM tool calibrated? If it is calibrated, is the measuring cell clean? Please do cleaning by selecting the cleaning icon. if already, do the standard sample measurement again. For futher information, please do not hesitate to contact us ([email protected]) Thank you
@nabilaothman2623
@nabilaothman2623 4 жыл бұрын
Hi there. Can this cleaning steps use for svm 4001, which has 2 measuring cells? If so, may i know where to do the rinsing with cleaning liquid and drying for each cells? If I clean the rotor of cell 1, i should rinse from cell 2 (outlet) right? Then Should i remove the rotor for cell 2 before i start rinsing cell 1? And when i clean rotor for cell 2, is the rinsing from cell 1 (inlet)? Another question, in the lab i work at, the svm cell 1 is set at 40 degree C and cell 2 is set at 100 degree C. so very hot when i remove the rotor of cell 2. Should i set the temperature to below 50/60 before i clean cell 2? Thank you!
@equivaligandindonesia
@equivaligandindonesia 4 жыл бұрын
Hi Nabila, Yes of course. Notice. Handle the measuring rotors separately and one after the other. The measuring rotors or their parts must not be exchanged. Otherwise, viscosity values are no longer valid. Leakage might occur. For detail information you can read in the manual book section 9 Upkepp and Additional Cleaning. In order to remove the rotor, it is recommended to first remove the rotor in room temperature conditions to make it easier to remove the rotor.
@muhammadtaufikputra6672
@muhammadtaufikputra6672 4 жыл бұрын
Mau tanya pak/bu, unit yang saya pakai ini tidak punya tampilan cleaning indicator dan tidak bisa tau cleaning value nya, cara memunculkan nya dimana ya? Saya hanya menemukan quality factor nya saja di live raw data. Mohon penjelasannya pak/bu
@equivaligandindonesia
@equivaligandindonesia 4 жыл бұрын
Selamat siang Pak, Pada quick access area pilih icon << (berada paling kanan pada home screen) terdapat icon setting, disana bisa dimunculkan pak cleaning value nya. Jika masih ada yang ditanyakan silahkan email ke [email protected]
@siqbel6196
@siqbel6196 4 жыл бұрын
Ditempat saya jg ada alat Anton-Paar . 👍
@equivaligandindonesia
@equivaligandindonesia 4 жыл бұрын
Mantap, semoga bermanfaat dan awet alatnya ya pak
@fadhelfebriangafar3602
@fadhelfebriangafar3602 Ай бұрын
kerja dimana pak pakai anton paar? Produsen aspal kah ?