Пікірлер
@cleudemirsilva4793
@cleudemirsilva4793 2 ай бұрын
I'm subscribed to your KZbin channel and I really enjoy the content and information you provide on maintenance and testing.
@FredAndrea-z3p
@FredAndrea-z3p 4 ай бұрын
Davis Scott Taylor Maria Jones Michelle
@serialupdates2330
@serialupdates2330 10 ай бұрын
Why black cable connect in conductor red cable in screen or armored
@iamfromthegov
@iamfromthegov 2 жыл бұрын
what percent of difference constitute a failure between cables
@bromaengiu
@bromaengiu 2 жыл бұрын
This is excellent. Thank you very much!
@hongildon8877
@hongildon8877 2 жыл бұрын
U are the best, man!
@aminsheilaandkiddos1686
@aminsheilaandkiddos1686 2 жыл бұрын
Thanks for the great knowledge...Would you share with us if the cable is in the subsea? What is the best method to find the cable fault or low Insulation resistance?
@D.Hozzie
@D.Hozzie 2 жыл бұрын
Excellent. Thank you for having this available
@irvinbriggs1161
@irvinbriggs1161 3 жыл бұрын
open your mouth and talk a little harder
@qus.9617
@qus.9617 3 жыл бұрын
This cleared up a lot of misconceptions I had about tdr. Immensely helpful video.
@helendu5241
@helendu5241 3 жыл бұрын
Do you need to remove the cable from SWGR before the cable test? What are the cons if the cable is connected on both ends of it?
@konbonfahchannel3626
@konbonfahchannel3626 4 жыл бұрын
Thank you!!
@aliumair3975
@aliumair3975 4 жыл бұрын
audio was not clear. please make it clear
@yasseryusuf4174
@yasseryusuf4174 4 жыл бұрын
Thanks. Where is part two ?
@sunilkumarsharma6462
@sunilkumarsharma6462 5 жыл бұрын
Thanks a lot Thomas Sir for your valuable Coaching
@josefbotha1346
@josefbotha1346 5 жыл бұрын
Thank for sharing
@EngineerRonaldGiler
@EngineerRonaldGiler 5 жыл бұрын
Thank you!! Please part 2
@EwavesTech
@EwavesTech 5 жыл бұрын
Good inform
@ivandavis4357
@ivandavis4357 6 жыл бұрын
great webinar
@ashrafelmarawany6825
@ashrafelmarawany6825 6 жыл бұрын
Thanks .sir .but I have a question what about using mejjer for testing a wire (line and natural ) used as a lighting homerun
@aswinhidayat941
@aswinhidayat941 6 жыл бұрын
need part 2
@earlmcginley9847
@earlmcginley9847 6 жыл бұрын
Need part 2
@uniqueman396
@uniqueman396 7 жыл бұрын
Hi coach, thank you for this course. please let me know about HV cable there is fault locator for HV cable? My regarding
@pearlzarb
@pearlzarb 7 жыл бұрын
<3
@ghanimuhammadusman2891
@ghanimuhammadusman2891 7 жыл бұрын
greatly appreciate for you kind time that you gave to make this video and uploaded. this video helps a lot. I hope you will upload more videos
@ghanimuhammadusman2891
@ghanimuhammadusman2891 7 жыл бұрын
I greatly appreciate for this video.
@davronengineer2519
@davronengineer2519 8 жыл бұрын
Thank you ever so much for relevant update !
@asadalisyed9938
@asadalisyed9938 8 жыл бұрын
dear sir this video sound very low please valum up
@pablomartinez8344
@pablomartinez8344 8 жыл бұрын
Really good video, This video cover exacly whay I needed to learn. Is there the second part somewhere? Thank you in advance.
@wkhanhangu3229
@wkhanhangu3229 8 жыл бұрын
thanks you
@faisalnawaz7162
@faisalnawaz7162 8 жыл бұрын
Dear excellent things for learning. you did it great
@paulmcqueen4749
@paulmcqueen4749 9 жыл бұрын
What PD threshold do you abide by on XLPE cables? Is there a std that states this?
@leeforrest9661
@leeforrest9661 3 жыл бұрын
i guess Im kind of off topic but does anyone know a good place to watch new movies online?
@fahadk484
@fahadk484 9 жыл бұрын
THAN K YOU FOR THE DETAILED EXPLANATION
@hanash8
@hanash8 9 жыл бұрын
PERFECT ,BUT WHERE IS PART2
@paulmcqueen4749
@paulmcqueen4749 9 жыл бұрын
What happened to part two? Its everything that I want to learn.
@franciscoalvarez5215
@franciscoalvarez5215 10 жыл бұрын
Thanks for this upload. Respects.
@alexandergale4514
@alexandergale4514 11 жыл бұрын
thank you this was a massive help towards my assignment
@superlocator69
@superlocator69 11 жыл бұрын
Great stuff! But what happened to part 2?
@albaraki
@albaraki 11 жыл бұрын
Thanks for the vid, i have a question, what is the minimum insulation resistance of MV cable (13.8kV) for it it can be considered healthy cable?
@cc519
@cc519 10 жыл бұрын
Normally when you are cable testing. There are done in sets of three (Three phase 13.8kV). Typically you compare the three. If one is very low compared to the other two. Then it would be up for concern. IF there all low. (kV low) You have a connected ground somewhere. Now assuming this is a 13.8kV distribution transformer having a wye connection...you probably know where I'm getting to. According to NETA standard the min IR resistance for a 15kV cable is 5 megaohms.
@rolandocera8000
@rolandocera8000 10 жыл бұрын
the question is how many mega ohm is acceptable for testing a medium voltage..low voltage cable.
@an5hontrapposelli650
@an5hontrapposelli650 9 жыл бұрын
+rolando cera kk
@asadalisyed9938
@asadalisyed9938 8 жыл бұрын
10 mega ohm's minimum insulation resistance
@Abdu86x
@Abdu86x 11 жыл бұрын
thank you
@paulwharton9845
@paulwharton9845 11 жыл бұрын
Excellent, just what I wanted. Where is part 2 please.