400/220/33 kv transformer, in 33 kv side (tertiary side)BIL 72.5 kV, how to calculate 33kV side cable sizing,
@edisonjohnson45577 күн бұрын
Sir, What is the exact difference between open delta and broken delta pt.
@ronaldosilva33014 күн бұрын
Nice explanation!
@surya.r346317 күн бұрын
Thank you sir
@annkitvj17 күн бұрын
Pls make videos on Transport testing as per IS
@s.senthilkumar13620 күн бұрын
Excellent demo 👌
@lokeshchandra-jl4wn23 күн бұрын
very nicely explained
@djturbine756527 күн бұрын
Is this relevant to the UK system?
@ENGRMDRAKIBULHASAN29 күн бұрын
What is the Suitable value for pH? (motor 3150KW, 11Kv, R-Vol: 2305 Ro-Amp: 828A) please reply me, Thanks sir
@rupeshsivakumar1748Ай бұрын
Crisp, well explained. Thanks
@divyadongele9713Ай бұрын
Thank you sir, you understand very well and your material content is very best. Keep uploading substation related videos like this and keep giving us knowledge.
@ahmadrazarizvi7819Ай бұрын
Noise issue
@asifasj6479Ай бұрын
Sir What is the reason for during resistance out time , stator carries high current, more than 5 times of full load current
@MadanSingh-un9ymАй бұрын
Ais substation installation commissioning video Hindi
@charinath5445Ай бұрын
In an M-T-M configuration, when carrying out short-term (momentary) paralleling, where should the synchro check relays be placed? a) On the Main Incomers (A & B)? b) On the Tie? c) On both the Main Incomers and the Tie? What is the standard practice?
@alimohibkazmi89732 ай бұрын
how to size the PT Fuse ???
@priyal53542 ай бұрын
Vs =60V will appear across secondary terminals of CT, right? How to choose Is?
@vasc07332 ай бұрын
If i understood it correctly, the thermal withstand curve (running) is for safe stall time/ stall time, and locked rotor withstand curve is for lrc cold and hot right ?
@housseineltahan55822 ай бұрын
Please Can you help me How to do wiring in reactor???
@nagarajamk70262 ай бұрын
Excellent Video, informative and nicely explained. Gurubhyonamah.
@hayderameer17672 ай бұрын
Hi Gents i don't understand what is reset factor of GEN. & why is consider 0.95 ?
@velmuruganperumal53222 ай бұрын
Basics well explained using good hand sketches and good English communication. Thank you.
@gautamev74732 ай бұрын
Sir in definition you are saying pick up current as 120% of full load current however in calculation you are dividing it by CT ratio. I guess definition should be corrected. Similarly for PSM.
@adityayadav67122 ай бұрын
Very much useful sir❤ I HAVE WATCHED ALL YOUR VIDEOS,TOO IMPORTANT FOR INTERVIEWS
@kucingbloon84622 ай бұрын
Good video, thankyou.
@dipdevilgaming53012 ай бұрын
What about the harmonics ?
@Mtenesac3 ай бұрын
Why the angle between the vref and the flux v is not 90 degrees, i have seen many text that stated that, by the way thank you very much for the content i am studying this at my university and i am a little bit struggling haha
@sumitsahu1313 ай бұрын
Nice explanation
@suchayan-vu2ld3 ай бұрын
0.859 sq.inch=554sq.mm, provided Busbar 1000sq.mm>554sq.mm; Hence 1000sq.mm is more than the required minimum size busbar.
@ashokar91353 ай бұрын
Hi I believe in both the fault conditions NCT sec. Current direction direction will be same. Your considering two different directions for outside and inside faults. Could you please correct me if I am wrong
@lovemybrothers7273 ай бұрын
Great effort friend
@chamiduabeynayake47533 ай бұрын
Great one small explanation but all thing include
@krnair22553 ай бұрын
Aptly explained. Hope this the tutorial will aid students as well as beginners of profession a handy presentation. Thanks a lot.
@mohammedt29564 ай бұрын
Long time
@AbeerBaber-h8p4 ай бұрын
It was really informative video. Please can you provide a clear view regarding Io and I1' both are same and if they are not, then Is Io will be considered as no load current or I1'?
@deltawye2974 ай бұрын
amazing video.
@EberFarmo4 ай бұрын
Hi. Are you sure about your explanation for close the disconnector???? 9:00 to 10:00 You can not close the disconnector just because the voltage of both side is equal.
@electricaltechnologyandind53354 ай бұрын
Possible. Isolator can be closed if there is no change in current or voltage.
@EberFarmo4 ай бұрын
but you did not say that in video. Please check again your description about the priority of disconnector and circuit breaker. You said before opening the outgoing CB , you could close the disconnectir. Even you said , first close the coupler CB and after that close the bypass disconnector . It is completely wrong and impossible
@abirjana81674 ай бұрын
Thank you sir,so much helpful🙏🙏,Plz Upload new video☑️
@abirjana81674 ай бұрын
Thank you sir,very informative video🙏🙏,Plz Upload new video☑️
@abirjana81674 ай бұрын
Thank you sir,so much helpful🙏🙏,Plz Upload new video☑️
@sumangorai20314 ай бұрын
How to calculate generator or transformer earth fault current which one we are limiting through NGR.
@kumaran414ify4 ай бұрын
can someone pls share link to part 2 of this video
@sumangorai20314 ай бұрын
When outside fault are occurring near light why mcb are phase 50ka fault current..
@palashdas53464 ай бұрын
Need video on ferroresonence resistor
@sarans38235 ай бұрын
Can you please add some ups sizing contents for NiCd/Lead acid .