Meer W dan Wp 1 aug 2023
3:35
10 ай бұрын
boiler slim verwarmen
0:30
Жыл бұрын
013 VID20230423144153
1:11
Жыл бұрын
012 afname bij 0PV
1:08
Жыл бұрын
011 afname bij 800PV
0:36
Жыл бұрын
006 afname scope
0:34
Жыл бұрын
005 VID20230415181559
3:30
Жыл бұрын
004 VID20230415184612
0:28
Жыл бұрын
004 sol sel 3000
0:38
Жыл бұрын
003 sol sel 1520
0:43
Жыл бұрын
Пікірлер
@USA-Truck-Train-Ship-Car-lover
@USA-Truck-Train-Ship-Car-lover 10 күн бұрын
Oud maar een zeer leuk verslag, deel 1 en 2 is toch geweldig om naar te kijken, bedankt stoom heier.
@SiBex_ovh
@SiBex_ovh 12 күн бұрын
MultiSIBControl can be connected to Deye or only to a battery ?
@stoomheier
@stoomheier 11 күн бұрын
Sorry I do not know the answer.
@SiBex_ovh
@SiBex_ovh 12 күн бұрын
Does is possible to downgrade to FW6023 who seams the best ?
@stoomheier
@stoomheier 11 күн бұрын
6023 has the same bugs. I do not think they change anything. Therefore they do not present a change log...
@SiBex_ovh
@SiBex_ovh 12 күн бұрын
with MicroInverter a grid consuption 40W, without MI is 50W - and this is a problem here in this video ?
@stoomheier
@stoomheier 11 күн бұрын
When grid setpoint is set at 0W, then grid power should be 0W !!! It is not rocket science, this costs me 365kWh a year. Victron can do almost 0W (26kWh a year). Why can't Deye fix this?
@SiBex_ovh
@SiBex_ovh 11 күн бұрын
@@stoomheier I consume daily 34kWh and in my perspective a Zero Export to Grid, means NO any Watt to Grid at all, is the most important scenario and this 0,040W is just PERFECT, even set a "guaranteed consumption" to 300W is ok for me just have be sure nothing will go out to ElecticCompany. Even if device consume all 100W for consumption from grid will be ok for me . I understand you point of view - that should be 0W when we have small ongrid CT consumption. I will check that too on my 3f 12kW deye in 1mth. Thanks for showing problems what you discover, I will check them on my unit too.
@SiBex_ovh
@SiBex_ovh 11 күн бұрын
or other words, for me a grid setpoint set to 300W must give me SURE that any of Watt not be produced into grid - this is my MAIN topic. Your is to have a setpoint set to 0W. And both point of view should work, I hope in future your setpoint 0W or my 300W will work as should be ! True ZeroExport and True 0W from Grid.
@stoomheier
@stoomheier 10 күн бұрын
@@SiBex_ovh My year consumption was 800kWh. With deye always connected to the grid; my bill will be150%........
@SiBex_ovh
@SiBex_ovh 10 күн бұрын
@@stoomheier lol., so low consumption compare to my 9000-11000kWh/y. We have 2 oposite point of view on setpoint, I hope they do it perfect for both of us. BR
@USA-Truck-Train-Ship-Car-lover
@USA-Truck-Train-Ship-Car-lover 13 күн бұрын
Echt waar wat een geweldige video. !!
@Malamutoed-dc5lj
@Malamutoed-dc5lj Ай бұрын
what monitoring program are you using?
@stoomheier
@stoomheier Ай бұрын
at what time/ moment do you mean?
@Malamutoed-dc5lj
@Malamutoed-dc5lj Ай бұрын
@@stoomheier 2,10
@stoomheier
@stoomheier Ай бұрын
@@Malamutoed-dc5lj look at 2:00 At 2,10 is solarman. 2,16 is deyecloud . They both are not correct when you also have micro inverters. I bought Solar Assistant: that is beautiful.
@husainalli
@husainalli Ай бұрын
Do it all again in Chinese. It will make sense.
@erik7853
@erik7853 2 ай бұрын
Wel tevreden verder? Ik ben van plan de 12kw 3fase aan te schaffen
@stoomheier
@stoomheier 2 ай бұрын
Ik had hiervoor een victron multiplus2 en die hoorde je door het hele huis brommen als een lastrafo uit 1930. Andere merken kan ik niets over zeggen. Ik heb wel een relais met accuspanningsmeter om bij te lege accu het net aan te koppelen en bij een bijna volle accu het net aan te koppelen. De rest van de tijd ben ik dus off grid, at scheelt me 1kWh per 24 uur "eigen verbruik" voor de inverter. Na vele maanden heen en weer mailen heb ik vanmorgen antwoord gekregen. Ze bevestigen dat zij ervaren wat ik als "bug" heb aangegeven. Ze erkennen echter niets en het ziet er naaruit dat ze er verder niets aan gaan doen. Voor de rest werkt het perfect. Hi friend 1.For single-phase low-voltage inverters, there is no function to keep the energy from the MI from going to the grid at this time. The zero export to+ mode with disable solar sell can only limit the energy from PV and battery from flowing to the grid, it doesn't work for MI. 2. We have confirmed with our engineers that the new program does make a little change here. As in the video, modifying the grid charge will indeed reduce the charging current of the battery, but only a little bit, so this is a normal phenomenon. Hun "only a little bit" is bij mij 33%......
@elainemariamoreiraramosram7472
@elainemariamoreiraramosram7472 2 ай бұрын
Está fazendo falta para nós Sinéad O'Connor é a única e melhor voz de todos os tempos. Nos deixou cedo e por morte natural, mas está em paz com seu menino e na proteção de Deus. Nunca será esquecida através das tuas músicas que ficou pra marcar. Vou te ouvir e amar sempre minha cantora especial. ❤
@carlvanzelderen
@carlvanzelderen 2 ай бұрын
Ik snap het niet? Zie in het midden ook een symbool bij die 757 watt, wat ik niet heb.
@stoomheier
@stoomheier 2 ай бұрын
Dat is de "gen port" ingesteld om daar micro omvormers op aan te sluiten. Dan doet de inverter alsof dat gewoon panelen zijn en voedt het huis, de accu of desnoods het net. En juist die keuze "micro omvormers op de gen port" veroorzaakt alle ellende. Deye is ondertussen ingelicht en dan komen ze met hun bewijs video's dat het bij hen wel werkt........ Ja: ZONDER micro inverters maar met de gen port benoemd als "smart load". WAAR ben je dan mee bezig als ontwerper?
@stoomheier
@stoomheier 2 ай бұрын
Dit was bij een vorige software versie: kzbin.info/www/bejne/aHXJn3xsbdtoa9E
@smirnovd
@smirnovd 3 ай бұрын
turn off micro inverter input and check it again
@stoomheier
@stoomheier 3 ай бұрын
Wonderful idea. And what should I do with the micro inverters then?
@kgrzeg
@kgrzeg 3 ай бұрын
I have the exact same problem on Deye 5kw hybrid. Wrote the manufacturer about that, they said they'll try and look into that. In the meantime I found a workaround by using Home Assistant to switch Deye from "Zero export to CT" to "Selling first", wait 5 seconds and then switch back to "Zero export". The script is doing it every 1 minute. It seems to work for me, at least for now. If they'll fix it I'll let you know.
@joostkrabbe3545
@joostkrabbe3545 4 ай бұрын
ik denk dat ik te maken heb met het zelfde probleem, :(
@stoomheier
@stoomheier 4 ай бұрын
Succes dan met de ombouw.
@PHPJN7
@PHPJN7 6 ай бұрын
Ja eens houd het op
@JinAlba85
@JinAlba85 7 ай бұрын
Hast du den Inverter parallel am Hausnetz angeschlossen oder am Load vom Inverter?
@stoomheier
@stoomheier 7 ай бұрын
Deye-Wechselrichter sind echte Hybrid-Wechselrichter, Sie können sie also nicht parallel anschließen. Sie versorgen es mit einem Netz und der Ausgang des Wechselrichters geht an den Verteilerkasten.
@JinAlba85
@JinAlba85 7 ай бұрын
@@stoomheier Ja theoretisch ist es auch möglich den nur parallel am Grid zu betreiben. Dafür hat man ja auch die CT Klemmen um den Parallel zu betreiben.
@JinAlba85
@JinAlba85 7 ай бұрын
Hi, wurde das Problem mittlerweile durch ein Firmware Update gelöst?
@stoomheier
@stoomheier 7 ай бұрын
Nein, ich habe seit 4 august nichts mehr von importeur und herr Deye vernommen.
@gde-zwaan6900
@gde-zwaan6900 7 ай бұрын
Hier is het zelfde probleem maar kan er niet achter komen hoeveel rpm het vijzelmotor is ,normaar staat dat er op maar helaas niets hoop dat iemand dat weet het gaat idd over dielle idro14
@stoomheier
@stoomheier 4 ай бұрын
Ik weet niet meer welke parameter aangeeft welke motor er in zit, want dat wordt wel ergens genoemd/gebruikt ivm de tacho op de motoras. Ik heb zelf een besturing gemaakt en die van Dielle na 5 jaar niet meer in de parate kennis.
@bogdankushlyk
@bogdankushlyk 8 ай бұрын
nice. what do you have connected there as a microinv input?
@stoomheier
@stoomheier 8 ай бұрын
A deye micro 800 with two panels 375Wp end a APS 600 with two panels 245Wp each
@bogdankushlyk
@bogdankushlyk 8 ай бұрын
@@stoomheier so basically two microinverters, correct? did you put them on the same phase or different ones?
@stoomheier
@stoomheier 8 ай бұрын
Same phase, its a one phase inverter @@bogdankushlyk
@bogdankushlyk
@bogdankushlyk 8 ай бұрын
@@stoomheier got it. Thanks
@donlatinohits
@donlatinohits 3 ай бұрын
how is this working for you? is it very efficient?@@stoomheier
@jhopmann2000
@jhopmann2000 8 ай бұрын
Nice to see that it is working. BUT HOW DID YOU COME THERE? Can you describe the relevant settings? Please?
@christianhausfeld6184
@christianhausfeld6184 9 ай бұрын
Hallo, habe einen Deye 12k . Kann ich einen zweiten 12k an den Gen Port anschließen?
@stoomheier
@stoomheier 9 ай бұрын
Fragen Sie am besten Ihren Verkäufer.
@svn5669
@svn5669 9 ай бұрын
Kan het ook met een SE ?
@stoomheier
@stoomheier 9 ай бұрын
Geen ervaring met dat merk met die onzinnige optimizers.
@Doejedingdoejedans
@Doejedingdoejedans 9 ай бұрын
Welk systeem is dit?
@stoomheier
@stoomheier 9 ай бұрын
DEYE.
@mokum4me_944
@mokum4me_944 10 ай бұрын
Tja zo werken monopolies en kartels, op basis van vervreemding van eigendom.
@tomasg3905
@tomasg3905 10 ай бұрын
Thanks, I have seen the same problem when enabling battery. Buying anda selling Up to 90w all the time.
@frans4136
@frans4136 10 ай бұрын
Ongelofelijk mooie machine.
@frans4136
@frans4136 10 ай бұрын
Is dit een tweetact motor?
@stoomheier
@stoomheier 10 ай бұрын
met spoelluchtpompen.
@frans4136
@frans4136 10 ай бұрын
@@stoomheier Net als mijn vroegere Deutz OM122 dan. Ook een tweecilinder.
@christophweidner6801
@christophweidner6801 Жыл бұрын
Make no sense, if there is no Micro-Inverter on gen port, to activate this function
@stoomheier
@stoomheier Жыл бұрын
It is to show that the software error becomes visible when the gen port is set to microinv input. And I deliberately didn't plug in any micros because Deye told me there were some issues with enphase. So they couldn't use that as an excuse again. (I have Deye and APS micro inverters)
@stoomheier
@stoomheier Жыл бұрын
WHAT do you not understand? Where did I say that it is only activating the port and not connecting any micro inverter. Please stop defending the brand Deye. It is full of bugs!!!!!! Grid consumption is always, even with 700W coming in on the micro inverter input and 3kW on the MPPT for charging the battery and feeding the house.
@stoomheier
@stoomheier Жыл бұрын
By the way, after one week you still did not prove that Firmware 6024 is on your inverter. And still you say your inverter is working without any problems with this firmware that is only for testing and only in one inverter at Deye's factory and in mine inverter!
@christophweidner6801
@christophweidner6801 Жыл бұрын
@@stoomheier okay, that was not clear in the video because the is no power on MI. The software for the single phase is buggy, i don't mind an say anything other
@christophweidner6801
@christophweidner6801 Жыл бұрын
@@stoomheier I said that it is not MY inverter, but one of a customer. I have more than 100 pieces among customers. but almost everything 3 phase. may I not ask a question? I just want to understand the videos and offer help if necessary
@christophweidner6801
@christophweidner6801 Жыл бұрын
Which firmware?
@stoomheier
@stoomheier Жыл бұрын
6024
@stoomheier
@stoomheier Жыл бұрын
Apologies, previous answer was incomplete. FW with errors is 6022 and 6023. The 6024 is not on the market I just got it for review / test from Deye.
@christophweidner6801
@christophweidner6801 Жыл бұрын
@@stoomheier i know. The 6022 and 23 are very buggy
@PhilippeCJR
@PhilippeCJR Жыл бұрын
Any idea to mail this video to Deye support and ask?
@vostraga
@vostraga Жыл бұрын
Yep, I have the same.
@stoomheier
@stoomheier Жыл бұрын
Deye is working on it. I received update FW6024 on april 21 for the 1 phase 8kW . It look the same. I keep you informed.
@christophweidner6801
@christophweidner6801 Жыл бұрын
And now?
@stoomheier
@stoomheier Жыл бұрын
Deye software department is working on it.
@stoomheier
@stoomheier 11 күн бұрын
1 year later deye told me they will not fix this.
@christophweidner6801
@christophweidner6801 11 күн бұрын
@@stoomheier I am also quite disappointed with deye...
@stoomheier
@stoomheier 10 күн бұрын
@@christophweidner6801 I have 6 more bugs in the firmware........
@stoomheier
@stoomheier Жыл бұрын
After trying the newest firmware, (not yet available for others) this problem seems to be history.
@pa7fa
@pa7fa Жыл бұрын
Dit is wel heel vaag.
@gilbertviloria2366
@gilbertviloria2366 Жыл бұрын
Your ac couple production will take the house load and the rest goes to the grid, it will not charge your battery unless you disconnect your inverter from the grid…
@videosfromniek
@videosfromniek Жыл бұрын
Als ik het goed begrijp heeft u de AC uitgang van de SMA aangesloten op ACout 1 van de Multiplus. (PV installatie is van mij 8Kwp) enphase 230 volt. Wat is de max stroom op ACout1. PV zit via relais op AC net.
@stoomheier
@stoomheier Жыл бұрын
Daar kan ik geen antwoord meer op geven. Ik heb vanwege de nare 50Hz brom die continue uit de multiplus kwam, de inverter het huis uitgegooid. Heb nu een 1 fase 8kW hybride inverter van DEYE.
@gerardkolenbrander5797
@gerardkolenbrander5797 Жыл бұрын
Top al die oud DSC Mannen
@myvideostudio7143
@myvideostudio7143 Жыл бұрын
can you pls video the CT wire connected to deye inverter...
@stoomheier
@stoomheier Жыл бұрын
CT is not active, setting is: Zero export to load. Solar sell? YES.
@myvideostudio7143
@myvideostudio7143 Жыл бұрын
wrong connection.... CT
@stoomheier
@stoomheier Жыл бұрын
NO inverter always take 1kWh every day. THAT is the problem. kzbin.info/www/bejne/d4OQZJ-hiNZljsk
@biancademilo
@biancademilo Жыл бұрын
Enige uitleg, behalve die paar sheets, over wat je doet en waarom zou een verbetering zijn op uw video 's Enkel wie nu (een beetje) bekend hiermee is kan u volgen . . . Bedankt voor het delen en tot de volgende (je hebt toch een duimpje van me gekregen 😉😂)
@stoomheier
@stoomheier Жыл бұрын
Dank voor uw reactie. Ik ga er vanuit dat iemand die niet kan zien wat er gebeurt ook geen oplossing zal kunnen geven. Het lijkt me gewoon een softwarefout. Je kan tegen deze omvormer zeggen dat hij niet mag terugleveren het net op. Dat blijft hij echter doen. Ondanks dat ik NIET toesta om solar te verkopen (solar sell). Verder kan je tegen deze omvormer zeggen dat hij de kWh meter op nul moet houden. Dat is erg belangrijk in landen met prepaid kWh meters, die gaan in storing wanneer wordt teruggeleverd. De mogelijkheid bestaat dan om het referentiepunt / instelpunt (grid set point) op 50W te zetten. De omvormer probeert dan altijd rond de 50W afname te zitten. De ene keer zal dat 90 W zijn, de andere keer 10W. In de hoop nooit op -10W te komen. Ik heb hem op 000 staan en toch levert hij terug. En in het tweede deel van de video (met die setting ook op 000) gebruikt hij 40W. Ook al is er overdag volop zon en in de nacht volop in de accu.
@okaymak
@okaymak Жыл бұрын
Hoe is de installatie gedaan met de meterkast? Grid aansluiting van de omvormer is aangesloten op het net. Load aansluiting van de omvormer voorziet het huis van stroom?
@stoomheier
@stoomheier Жыл бұрын
correct. Kabel naar de Deye (grid) komt vanaf de hoofdschakelaar in de groepenkast en de kabel van Deye (load) =UPS gaat naar de groepenkast-"rails" waar de aardlekschakelaars op zitten. Het hele huis heeft dus nog spanning bij netuitval. En panelen blijven dan actief.
@okaymak
@okaymak Жыл бұрын
De voorbeelden die ik van Sunsynk heb gezien gebruiken de load uitgang alleen voor essentiële zaken, zodat zware verbruikers niet je accu leegtrekken. Via de gewone grid aansluiting wordt de rest van stroom voorzien. Voor beide is wel iets te zeggen. Maar bv als je omvormer te zwak is, dan kun je niet aanvullen vanuit het grid. En hoe vaak zal het grid wegvallen.
@michaelvw11
@michaelvw11 Жыл бұрын
Precies de vraag die ik wilde stellen 😁
@michaelvw11
@michaelvw11 Жыл бұрын
Het beantwoord ook gelijk de vraag die bij mij opkwam, zodra er net uitval is en de generator input waar een netsynchroon omvormer op aangesloten is, geeft deze dan spanning waar de net synchroon inverter tegen aan kan hangen. Blijkbaar wel als ik het zo zie 👌
@PhilippeCJR
@PhilippeCJR Жыл бұрын
@@michaelvw11 ik heb de 12KW 3fase variant van Deye Hybrid. Alleen Grid port aan gesloten, gewoon achter de HS in de MK. Die keer dat t grid uitvalt zet ik de HS wel uit, en wissel ik de 4 draadjes van GRID port naar LOAD port in de Deye. Loopt het huis ook door op solar+accu. Die keer in 5 ...10 jaar? Dikke bak wel die 12kw ! :)
@philippekhaki2320
@philippekhaki2320 Жыл бұрын
Kajun KKK
@zidan07168
@zidan07168 9 ай бұрын
What?
@carlossantini
@carlossantini Жыл бұрын
did you find a sollution to this problem?
@riendiemel6346
@riendiemel6346 Жыл бұрын
Ik heb je proberen te bereiken via het pelletkachel forum maar ik begrijp dat je daar niet zo vaak komt kijken. Ik heb een Dielle Scirocco Evo 60 en heb nu na 5 jaar hetzelfde probleem gekregen met de uitgesleten as. Vorig jaar begon het lawaai met oorverdovend zoemen en trillen vooral bij het opstarten. Ik had geen idee wat de oorzaak was maar door jou filmpje wijs geworden. Na het afschroeven van de dekplaat zag ik direct dat de as de branderpot had uitgesleten wat een schande is voor zo een dure kachel. Na lang zoeken ben ik erachter gekomen dat er geen Dielle importeur meer is in Nederland maar een agentschap. Dit is 123pelletkachels uit Steenwijk. Ik kan daar ook niet meer aan een modificatie set komen. Ik heb een nieuwe branderpot besteld maar wanneer die komt en hoeveel dat kost was niet bekend. Wat ik mij wel afvraag of de vijzel as bij mij ook krom is want dan heb ik een mega probleem. Zit er aan de achterkant wel een lager? Ik kan dat zelf moeilijk bekijken. Heb jij enig idee of zo een vijzel as altijd krom trekt? Bij het opstarten stopt de vijzel soms met draaien maar als de kachel op temperatuur is draait hij wel goed. Als ik een nieuwe branderpot krijg is dat dezelfde als ik nu heb dus na 4 jaar krijg ik weer hetzelfde probleem. Zou ik een koperen glijlager kunnen laten plaatsen bij een metaalbedrijf met een diameter van 16mm? De nieuwe Dielle kachels hebben sinds 2 jaar een modificatie waarbij ze de as wel gelagerd hebben maar niet te gebruiken voor onze kachels. Ik ben zelf geen techneut maar hooguit een handige doe het zelf'ver van 70 jaar dus daarom veel vragen. Hopelijk kan je me een beetje helpen. Je kan me ook bereiken via [email protected]
@stoomheier
@stoomheier Жыл бұрын
Dat pelletkachelforum was van euronkachels/ Nando Boogaars (nu AAAeco). Je snapt vast wel dat ik daar een IP blokkering heb gekregen na enkele kritische opmerkingen over zijn functioneren als importeur. Ik heb ondertussen ook aan de motorkant een kogellager en een taatslager geplaatst, daar zit de stalen as in een bronzen bus. Dit soort bedrijven zijn zo vreselijk frustrerend. Zetten een prototype op de markt en geloven het dan wel. En dan voor die prijs. Schandalig. Kachel doet het nu wel goed. Heb ook kans gezien zelf een print en besturing te maken. Helemaal onafhankelijk van die importeur. Succes met de reparatie. Ik heb ook geen onderdelen en had niet het plan om zelf kitjes te gaan maken.
@LVBRIP
@LVBRIP Жыл бұрын
what a useless vid.
@christiankulmann3325
@christiankulmann3325 Жыл бұрын
With the Dimmer + PV, self-sufficiency will now increase to almost 95% in summer, which means a huge breakthrough. The prerequisite is that you have at least a small balcony power station, and you don't need an expensive battery either. Example of a kettle: Without a dimmer, the 2500W - 600W PV system needs = 1900W, which you have to pay more for. If I turn the kettle down to 600W with a dimmer, then every weak PV system can now supply each consumer independently and independently, because the 2500W kettle becomes a 600W kettle thanks to the dimmer. Magic... The 2000W e-heater becomes a 500W e-heater with a dimmer, which can run 12 hours a day free of charge via PV. kzbin.info/www/bejne/h5OviHeYf85pm9k . The 4000W oven is also tamed. Not the solar systems have to grow, but the consumers just have to drop by 75%, which is sooo easy with the dimmer. are you convinced now I have already switched my entire household to dimmers. Please have a look at my channel. ............. 🌞 ...................... ..................................................
@christiankulmann3325
@christiankulmann3325 Жыл бұрын
With the Dimmer + PV, self-sufficiency will now increase to almost 95% in summer, which means a huge breakthrough. The prerequisite is that you have at least a small balcony power station, and you don't need an expensive battery either. Example of a kettle: Without a dimmer, the 2500W - 600W PV system needs = 1900W, which you have to pay more for. If I turn the kettle down to 600W with a dimmer, then every weak PV system can now supply each consumer independently and independently, because the 2500W kettle becomes a 600W kettle thanks to the dimmer. Magic... The 2000W e-heater becomes a 500W e-heater with a dimmer, which can run 12 hours a day free of charge via PV. kzbin.info/www/bejne/h5OviHeYf85pm9k . The 4000W oven is also tamed. Not the solar systems have to grow, but the consumers just have to drop by 75%, which is sooo easy with the dimmer. are you convinced now I have already switched my entire household to dimmers. Please have a look at my channel. ............. 🌞 ......................
@pa7fa
@pa7fa Жыл бұрын
Mooi werk. Eindelijk een hybride die zonder onderbrekingen doorgaat als het grid uitvalt. Nu nog een pittige 3-fase versie met een hogere DC-accuspanning mogelijkheid. Dat zou de lijn wel compleet maken. Ook fijn is dat bij grid uitval de zonnepanelen het gewoon blijven doen, en de accu laden / huis voeden.
@stoomheier
@stoomheier Жыл бұрын
Battery Voltage Range (V) 160~800 bij de binnenkort te verwachten inverters 25, 30, 40 of 50kW....
@erwin757
@erwin757 Жыл бұрын
Wat een herrie idd! Wat zegt Victron hiervan?
@stoomheier
@stoomheier Жыл бұрын
Na lang genoeg klagen hier en daar (blijkbaar) is de multiplus2 op 3 mei terug gegaan naar de groothandel. Die heeft ook geconstateerd dat deze MP2 lawaai maakt. Daarom is hij naar Victron Almere gestuurd. Daar vindt men echter dat hij fluisterstil is........ Gelukkig staat nu wel zwart op wit dat zonder accu opstarten aan het net, zodat dat wordt doorgeschakeld, geen kwaad kan zoals eerder wel beweerd werd. Ik heb hem dus toch niet kapot gemaakt, wat wel beweerd werd. Ondertussen al 22 dagen zonder inverter......... Je zou er maar van afhankelijk zijn. Service laat dus duidelijk te wensen over. Ik heb wel begrepen dat er meer problemen zijn met dit type. . . Na klagen over wachttijd kreeg ik bericht van de groothandel dat ik hem kon ophalen. Was niets aan gedaan. En de groothandel wist ineens te vertellen dat zij de inverter naar Almere hadden gestuurd voor een second opinion. NIET omdat ook zij vonden dat hij herrie maakte..... Dus die groothandel is ook maar een marionet van victron . Ik heb deze MP2 kunnen verkopen aan iemand die hem in een garage gaat hangen. Ik heb nu een 8kW Deye, die fluisterstil is.
@aplancelot
@aplancelot 2 жыл бұрын
We’re you able to find out what the problem/solution was?
@stoomheier
@stoomheier 2 жыл бұрын
NO.! I sold it to someone who will instal it in a shed. The multiplus went back to the wholesaler. They found it noisier than normal and shipped it to Victron Netherlands. Victron said it was quiet as a mouse........... So back to the wholesaler, who promptly told me that they did sent it to Victron for a second opinin, NOT for the "more noise"..... So the wholesaler is just a puppet on Victron's strings. I will NEVER buy a victron product again! I think that very much/many (?) multiplus 2 and perhaps also the modern Quattro's have a huge noise problem, so Victron will try as long as they can to deny the noise problem......