Trust me the ADD and Invert work perfect when probing into unknown territory. In high school (1970's) we were taught differently and will not go there do to liability but is does work and prefer not to use that method. It wasn't until I acquired a Tek 7854 which had a differential plugin only to find out later when someone showed me this method the plugin is not needed on a dual trace with ADD and channel 2 Invert. Just remember like this gent said if you were wanting to look at a phase in a motor controller even at just 20 amp fused that ground lead at 16AWG at best will pretty much explode in your hand and molten copper slung everywhere along with melted insulation. Also good 10X probes are not a bad idea either as most budget scopes only go up to 10 volts per division. Good job with the video.
@TheFinalFrontiersman7 күн бұрын
I'm currently a year 2 mechatronics student at BTC!! I found one of these in our trash bin and I've been cleaning it up and playing with it, and look what I stumble upon in researching it! If you are who I think you are, we used your EE textbooks and coursework last year and it was really good! o7
@sparkyfromel10 күн бұрын
Good God , worked with the 13A all over the world , that was when the US was at the front of technology
@Gamer2008hLVEH214 күн бұрын
cool
@bimbo-yw6ny15 күн бұрын
what i don't understand, why an NC contact is a not true once it allows current through and make the output true energized, ? i understand is the opposite of the NO, ..., but i found several videos with Nc Stop button once open once closed, ...?
@NancyAnderson-n7m20 күн бұрын
Presley Fall
@风景这边独好-g4k25 күн бұрын
I have a question that has been bothering me: after changing the settings of the protection relay, do I still need to conduct a test? For example, the overcurrent protection has been changed from 5A to 6A. Do you still need to test the relay protection? Thank you
It would be very informative if it’s possible to make demonstration when water level goes below water pump level and how to provide suction when water level is below pump
@CptWesker07Ай бұрын
I got confused by this so I asked ChatGBT to describe to me the difference like I'm 5 years old! Hub: Imagine a big classroom where the teacher (the hub) shouts every message out loud to everyone in the room, even if the message is only for one person. Everyone hears it, but it might be confusing or noisy, because every message goes to everyone, even when it's not for them. Switch: Now imagine a smart teacher (the switch) who knows exactly which student the message is for and whispers it directly into their ear. Only the person who needs the message gets it, and it’s much quieter and faster for everyone else. In short: Hub: Yells everything to everyone. Switch: Sends the message only to the right person. Switches are like smart helpers who make things quicker and easier by only sharing what’s needed!
@engsherif46572 ай бұрын
Great thanks for explean expermantal the cavation
@stretch62312 ай бұрын
Did this with my first pull. Good video, works well. Thanks.
@akpvdensolartv33892 ай бұрын
What kind of generator did you used?
@ptm47002 ай бұрын
Camera op should stop drinking
@bensherry47132 ай бұрын
Thank you
@aewcontrol29842 ай бұрын
you need to connect a 250ohm resistor in series for this, no?
@EonTide11112 ай бұрын
Is the signal generator and oscilloscope Both terminated at the entrance or positive lead of the cable ?
@Jerrec2 ай бұрын
Interesting video! I never saw a switch taking 5 minutes to update it's mac table. Is this a cheap netgear issue? Usually when a switch inidicates a port up, it refreshes the mac table.
@carmelpule84932 ай бұрын
My analogy of synchronising of three phase alternators is not using " rotating batteries" as that does not make sense. I rather thnk of three flying members of the red arrows flying 120 digress with respect to each other performing a " barrel roll in one direction and following them are three flying members of the Blue angels, The idea of synchronizing the two teams is to get a passenger in each of the blue angles to jump over to the cockpits of the red arrows Without ANYONE GETTING HURT. Hence the required state is that the each team must be 120 digress with respect to each other and roling on the same diameter circle and in the same direction . Only then the equality of the voltage, the right phase sequence and the frequency are met, The rotating battery is a silly example to suggest as it is much more than that, The two , three member display team is a more faithful analogy. Perhaps rather than two display teams one should use three fuel tankers while three F-22 are all trying to refuel at the same time with the three tankers flying the equivalent of a three phase supply system, with the three F- 22 following with the required synchronised state! Hunting about the final point is interesting and excitation and throttle control is not explained by using " rotating batteries". One can use a similar demonstration using synchros or two wound rotor induction motors, If one excites the rotor with AC and rotate the rotor one can get a rotating three phase on the stator Two such motors excited from the same AC source can remain non rotating with a similar effect . Also the three light bulbs are not connected so that they all show zero voltage at synchronization but two will be bright and one will be dark. and they do show the difference in rotation and not only the pulsating effect, A synchroscope is only a unit with a three phase winding on the stator and a three phase winging on the rotor where the excitation from the two incoming alternators rotate the magnetic fields in different directions with the shaft of the unit remaining stationary at a particular direction when synchronization is best to be activated. ,
@osmmanipadmehum2 ай бұрын
is there a way of braking a motor without spending electricity but instead generating it? I know, regenerating brakes, but how does one keep a constant rpm?
@Hoxworldph2 ай бұрын
Your video and set up is amazing. May i know if I can get your set up circuit for me to follow it and assemble it as well? Thank you so much
@jedpallan72372 ай бұрын
Thank you
@jimmytowns24713 ай бұрын
I have watched numerous videos about synchronizing generators but this is the only one i found that explains how they stay in synch! Wonderful job my friend, great demonstration and explination about this process. Thank you!
@ZygmuntKiliszewski3 ай бұрын
Hello, I invite BTCInstrumentation and Internet users to analyze my KZbin channel and website. Best regards 💖😀.
@gurituna3 ай бұрын
it is a very claer explanation. why 220 idiots didnt like it :D
@aholesahole3 ай бұрын
Holy crap
@petercollin56703 ай бұрын
I used to work in the Foxboro factory, for 2 summers. I never completely understood what the parts I made did! I find it interesting how you said that your unit had the wrong diaphragm. I worked in the capsule room, assembling and welding the diaphragms and flexures onto the capsules, then filling them with oil. Were you actually swapping out the entire capsule?
@sparkyfromel10 күн бұрын
you swap the capsule if it get corroded and or leaking , loosen the stirrup and re-tighten the fixtures one at the time you should get ~ the 3 PSI zero , the next problem is static alignment , increasing the pressure equally on both sides and still stay at zero differential
@AustinMayer3 ай бұрын
This made my day. One of the coolest demonstrations of AC I have seen 🙂
@alvieteal49804 ай бұрын
So I’m gonna go on a limb and say so the neons are connected phase to phase of each generator?
@amirouw4 ай бұрын
عجب جامع و عالی بود توضیحتون
@NicholasKandis4 ай бұрын
"Probably the most complicated or confusing part is the torque tube itself..." Really?? Sure buddy.
@laripope76604 ай бұрын
Thank you, very well illustrated
@ANONM60D4 ай бұрын
by what process is a total NOx reading filtered to determine NO2 and NO3 levels?
@mashed-out4 ай бұрын
Be careful, that cavitation you see just after the suction valve is caused by the pressure drop through the valve not the pump...sending them to the pump.
@ashishkumartiwari70314 ай бұрын
Excellent 👍
@planktonfun14 ай бұрын
Isn't there a tool that do this automatically?
@GuwancHaydarow4 ай бұрын
Turkce anladsana megeometir sail ulanylya
@sictransitgloriamundi2304 ай бұрын
*Absolut GEIL! Danke für dieses Video.*
@nexbedwars74085 ай бұрын
thank you
@jeffclark52685 ай бұрын
Waiting for the conspiracy idjits to chime in about how the gubberment is clearly hiding the infinite energy machines because you’ve got 2 running right there.
@kareemali18115 ай бұрын
wireless intrinsically safe transmitter did need a zener or galvanic barrier in control room to limit the voltage and current . please can anyone answer me
@AliAli-ww4pg5 ай бұрын
If I have intrinsically safe wireless transmitter Ex ia did I need zener or galvanic barriers in control room
@tgsopher5 ай бұрын
There used to be a tool making this easy to do. I have been looking for a set, but I guess they are no longer available.
@4DRC_5 ай бұрын
Does the slave PLC not need any code for modbus? If I’m seeing send/receive instructions in a ladder program do I immediately know I’m reading a program meant for a master PLC?