Corrosion rate got initially is 0.0054 inch/year but you have taken 0.5 while calculating Remaining life
@inspectioncorrosion Жыл бұрын
RLF calculated for first example where CR in mm/year
@mohamedriyasdeenm5630 Жыл бұрын
The above all Inspection Are Qualified by Cerified person or Can Anybody be a Qc Inspector with experience.
@mohamedriyasdeenm5630 Жыл бұрын
For example API 510 Are certification So would All do this or Simply can Be an QC insp
@inspectioncorrosion Жыл бұрын
Experience important but certification also required for inspector to prove his knowledge and skills as per Client requirements
@mohamedriyasdeenm5630 Жыл бұрын
@@inspectioncorrosion that is my problem sir, Actually I was working as QC Welding Inspection And Need lots of cource cert to prove who am I.. so, I desicided to change mechnical Technician Job In Same Field Refenery or oil and gas plants... That's it Sir.
@sanatanvedicdharm1999 Жыл бұрын
Gd morning sir, What is code of CS, ltcs and alloy bolt code
@inspectioncorrosion Жыл бұрын
Find details in ASME B18.2.1, B18.2.2, B18.31.2, B16.5
@amirulafif9000 Жыл бұрын
What the Latest technology for inspection and monitoring atmospheric corrosion?
@inspectioncorrosion Жыл бұрын
New development ongoing like corrosion monitoring sensor available now in the market
@RyanBacheldorFMXКүн бұрын
Best way to find the front line is to find the competition. Tons of exciting things happening in the industry today. Understanding coatings and CP is a wild thought still. That's what makes it exciting.