How to Rail Mount a Tigo TS4 MLPE
0:41
OTIMIZAÇÃO TIGO MLPE
5:08
10 ай бұрын
Пікірлер
@bikhard1078
@bikhard1078 6 күн бұрын
I’m confused with the 120volt power supply to a 15 amp breaker? What does that mean? Can I not make plug or use a plug for this part?
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 3 күн бұрын
The DC power supply requires a 120V input (line and neutral) that typically goes directly to a breaker on the main panel. Since this device is used for rapid shutdown and will turn off your array if it loses power, we do not recommend plugging the device into a receptacle in your home. If someone inadvertently disconnects it you will lose array production since the TS4s will go into rapid shutdown.
@ronaldchong
@ronaldchong 8 күн бұрын
is the internet required for commissioning if i dont want monitoring? (you don't make an rsd and optimization only device so i have to get the ts4-o-a.) if the internet is not available, do i loose the RSD capability? surely not right?
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 3 күн бұрын
Great question! You will need internet at first since you must fully commission the TS4-A-O and complete Discovery for RSD to enable. After that, the TS4-A-O does not need the internet for rapid shutdown or optimization. But why wouldn't you want to know what is going on with your system? However, your application would impact the warranty conditions since we require an internet connection. You will drop from 20 years to only 5 years.
@ronaldchong
@ronaldchong 2 күн бұрын
@@Tigo_Flex_MLPE @Tigo_Flex_MLPE hey, thanks for the response! i didn't know about the "20-year only if" warranty thing. that makes my decision easier.
@ronaldchong
@ronaldchong 8 күн бұрын
cloud-dependency is not a feature if you ask me. i'd prefer the *option* for the cca to stream messages on a port on my local network that i could capture on a pc or raspberry pi. is this possible?
@grzegorztawkinowicz8387
@grzegorztawkinowicz8387 25 күн бұрын
Czy wy możecie uaktywnić automatyczne tłumaczenie na język polski. W Polsce także są sympatycy TIGO.
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 9 күн бұрын
Dobrý den a děkuji za váš komentář! Všechny jazyky jsou dostupné prostřednictvím nastavení KZbin. Klikněte na ikonu CC a poté na ozubené kolo. V rozbalovací nabídce vyberte Titulky/CC a poté vyberte automatický překlad. Poté můžete vybrat svůj jazyk z rozevíracího seznamu.
@pds4184
@pds4184 29 күн бұрын
Dude why dont you just spit in a cup or something ...VERY distracting. You might as well just light up a freaking cigarettes'.
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 11 күн бұрын
Sorry, we don't speak Dorkanese. Can you elaborate?
@savedforever7702
@savedforever7702 Ай бұрын
If I'm using two inverters in split phase then do I need 2 rss transmitters?
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE Ай бұрын
It depends on how many strings each inverter has. Since the RSS Core can accommodate 10 strings, as long as both inverters have 5 strings max, then a single transmitter may be used.
@savedforever7702
@savedforever7702 Ай бұрын
@@Tigo_Flex_MLPE Thanks for the reply. It will be 2 strings each inverter for a total of 4 so I will be able to use 1 transmitter. 👍
@londoncharging
@londoncharging Ай бұрын
When I try to connect via bluetooth to the CCA I am asked for a PIN, nothing seems to work, I've tried 1234 0000 9999 etc.
@fernandopalumbo4798
@fernandopalumbo4798 Ай бұрын
What is the distance máxima of the reception in meters
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 9 күн бұрын
The maximum distance between the CCA and the TAP is determined by the RS-485 communication cable. Typically, this distance is about 4000 feet. However, the transmission distance between the TAP and the farthest TS4 is 115 feet. Please contact our support line if you have any further questions.
@MrHakiii
@MrHakiii Ай бұрын
Brauch ich bei den tigo ts4 a o sonstige hardware um zu betreiben?
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE Ай бұрын
Um die 25-jährige Garantie aufrechtzuerhalten, müssen Sie CCA und TAP verwenden. Ist dies nicht der Fall, verkürzt sich die Garantie auf 5 Jahre.
@MrHakiii
@MrHakiii Ай бұрын
@@Tigo_Flex_MLPE wo ist der sinn?
@alexxela1788
@alexxela1788 Ай бұрын
I componenti si possono acquistare separatamente? Esempio io ho gia un alimentatore adatto, mi basterebbero cca e tap, dove acquistarli online?
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE Ай бұрын
Sì, puoi acquistare CCA e TAP separatamente. Tigo vende tramite distribuzione oppure puoi trovarli online.
@alexk6745
@alexk6745 Ай бұрын
somewhat useless. It is for dummies. without explaining its schema. In short. They claim it just works.
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE Ай бұрын
Can't give away all our secrets. Good thing the 1 TW of data we collect data proves our tech works.
@imacmacnerd
@imacmacnerd Ай бұрын
If the grid goes down and the hybrid inverter switches into backup mode, can the inverter supply power to the load center with just solar input only or does it needs the addition of batteries to do that?
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE Ай бұрын
Every hybrid inverter in the world must have a battery to provide power when the grid goes down. In backup mode, solar power is used to charge the batteries and power loads if there is enough left over.
@kolo1484
@kolo1484 Ай бұрын
Sehr hilfreich! Vielen Dank
@imacmacnerd
@imacmacnerd 2 ай бұрын
Hi, can you use other types of batteries with the Tigo inverter/ATS?
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 2 ай бұрын
The Tigo Residential Solution is compatible with AC Coupled batteries. Please contact the battery manufacturer to confirm this application.
@imacmacnerd
@imacmacnerd 2 ай бұрын
Do you have to have batteries to use this inverter initially? Or can you add them later after installation?
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 2 ай бұрын
Great question! You can absolutely add the batteries later, although you would need to also add the automatic transfer switch.
@StonesXu
@StonesXu 2 ай бұрын
Hola, somos una empresa de apoyo relacionada con el almacenamiento de energía. Queremos ver si hay alguna oportunidad de cooperar.
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 9 күн бұрын
¡Envíe un correo electrónico a [email protected] y estaremos encantados de hablar con usted sobre esta oportunidad!
@dfjr6525
@dfjr6525 2 ай бұрын
Don't call them if you need help on the install. Tech support was terrible for me
@dogfart8101
@dogfart8101 2 ай бұрын
Let me guess, you effed up something in this video, or didn't RTFM like this guy says, and now Tigo won't send you a replacement? 💩💩
@dfjr6525
@dfjr6525 2 ай бұрын
Na system is up and running now. Called for some help and the tech guy was just a dick. Actually you might be perfect for that job bud
@dogfart8101
@dogfart8101 Ай бұрын
Support gets like that when they have to talk to idiots. lulz, you liked your own comment 🧰
@harism5589
@harism5589 2 ай бұрын
Can I use this inverter TSI-3.8K-US 3.8kW 208/240VAC with no battery installed?
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE Ай бұрын
Absolutely! A hybrid inverter does not need a battery to operate and may only run on solar. However, it will not provide backup power when the grid goes down without a battery.
@fullyelectric
@fullyelectric 3 ай бұрын
I think you guys need to learn how to truly describe your products, most new people getting in to solar just want to save of crazy high electric rates, they don’t really care about off-grid they just want grid-interactive products thats crazy easy to install, like back feeding your main panel from the grid/AC connection on the inverter, and using any 48v battery with coms etc. take a look at the EG4 18Kpv and make it for a much better price and you’ll have a winning product in this space for new and existing solar customers.
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 9 күн бұрын
We do all of that, not sure where the confusion lies.
@fullyelectric
@fullyelectric 9 күн бұрын
@@Tigo_Flex_MLPE thats my point .. you know you do all that however its not clearly stated anywhere ..that is the confusion .. and it doesn’t matter if it’s in a manual because you only get the manual after you buy the product it needs to be clearly stated in the description of every product that support those feature on the website in ads etc.. plain and simple no confusion, that’s called marketing 101, the fact i have to make the post like this shows whatever you all doing now is not working and need to change. Just trying to help do nothing and remain at the level you are, does not affect me one bit.
@fullyelectric
@fullyelectric 3 ай бұрын
OMG Tigo i like your power optimizers but omg you should get rid of everyone who work on this new product, major flaw you can’t call any of your inverter hybrid because it support PV and Battery lmao 🤣, an Hybrid inverter is one that does GRID interactive, like 240v backfeed your main panel with PV or Batteries in conjunction with the grid!, and the ability to sell back to the grid if needed, only inverters with that ability are given the title Hybrid, you are the new guy on the block why start to confuse people who are new to solar etc.. also 120v inverters are mainly for off-grid small deployment, make better inverter with 240v for large off or on grid applications with competitive price, or EG4’s will continue to walk all over you!! You’ll never get in this space, best of luck.
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 9 күн бұрын
Yep, that is exactly what our hybrid product does- it allows PV, batteries and the grid to supply power to the loads. You may need to watch the video again or contact our sales team.
@fullyelectric
@fullyelectric 9 күн бұрын
@@Tigo_Flex_MLPE my issue is, its not clearly stated even in the video .. watch it again .. because you know it may seem its stated but you have to look at it from a new person to your product line prospective, and its not clearly stated, also people don’t like calling or emailing anymore, everyone want information clearly provided as they research a product and i can tell you other company does much better clearly marketing .. take a page out EG4 website and product features description anyone not familiar with this type of product can understand it clearly as it is stated very simplest. Hope this feedback helps .. just trying to help you guys out as i do not gain anything from this..
@fullyelectric
@fullyelectric 3 ай бұрын
OMG Tigo i like your power optimizers but omg you should get rid of everyone who work on this new product, major flaw you can’t call any of your inverter hybrid because it support PV and Battery lmao 🤣, an Hybrid inverter is one that does GRID interactive, like 240v backfeed your main panel with PV or Batteries in conjunction with the grid!, and the ability to sell back to the grid if needed, only inverters with that ability are given the title Hybrid, you are the new guy on the block why start to confuse people who are new to solar etc.. also 120v inverters are mainly for off-grid small deployment, make better inverter with 240v for large off or on grid applications with competitive price, or EG4’s will continue to walk all over you!! You’ll never get in this space, best of luck.
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 2 күн бұрын
You may need to watch the video again. We are a hybrid inverter and do all of those things.
@fullyelectric
@fullyelectric 2 күн бұрын
@@Tigo_Flex_MLPE the fact you have to say i need to watch the video again is a fail .. doing the same thing over again will not net anything new, a better video is needed.
@keithlee9378
@keithlee9378 3 ай бұрын
Hi a Question. I have 9 panels on one string on a ballast mounted tilt system. (Four panels on a roof for the other string). Three of the panels of the 9 panels string will get some shading. Can i just put the Tigo DC optimisers only on these 3 panels or do I need them on all the 9 panels of that string. Help
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 9 күн бұрын
Great question! You may only use optimizers on affected modules. Our Help Center article goes into more detail. support.tigoenergy.com/hc/en-us/articles/360024860193-TS4-Systems-Methods-of-Deployment
@user-rk8pb2pr5t
@user-rk8pb2pr5t 3 ай бұрын
15 year service tech here. Why did hollins ferry catch fire? Tigo sucks. Thats why. Why did santa barbara burn? Tigo. Why is your product so fire unsafe your company is banned in maryland districts? Oh. Its tigo. Thats why. Im so glad alexandria renew didnt use your product. I was responsible for them not purchasing this. 2 companies ill never install or service. Tigo and Delta. Not worth the liability to my insurance when it eventually burns a hole in someones roof. Oh and the sites i mentioned that burned, all were installed correctly which is why you guys settled.
@dogfart8101
@dogfart8101 3 ай бұрын
15 years and you still don't know how to install these? Looks like you need to watch more videos.
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 9 күн бұрын
It would be interesting if anyone from your company submitted their designs to our support team. Did any of the installers go through our online course or read the documentation that came with the products? Please share your company name and we can check on that.
@user-rk8pb2pr5t
@user-rk8pb2pr5t 9 күн бұрын
@Tigo_Flex_MLPE my comment isn't to help your company. My comment is to mainly mock but also make installers aware of the liability and how counties in a state banned your product. All of our electricians are journeyman at minimum and any solar tech touching wiring is NABCEP. We do weekly meetings with product updates and quarterly company wide meetings so when people like you sound stupid asking questions like, "did they take our course", of course they did. They are fucking professionals. Weve worked extensively with solaredge r&d and set their SOP for troubleshrooting synergy inverters. We are second to none in commercial industry east coast. And your companies products start fires.
@user-rk8pb2pr5t
@user-rk8pb2pr5t 8 күн бұрын
@Tigo_Flex_MLPE why you delete my response?
@earthenergyhex
@earthenergyhex 3 ай бұрын
I didnt know Tigo sold inverters. I have been looking to replace my Schneider Electric System. I am going to take a hard look into Tigo
@SaymonPM
@SaymonPM 3 ай бұрын
When designing the RSS transmitters, where should we achieve the source of the main power supply unit that converts the a/c to dc voltage for the transmitter itself? Meaning do you install the Transmitter kit via power supplied from the Solar system, or the utility system?
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 3 ай бұрын
Great question! The RSS Transmitter must be fed by an external 12V/1A power supply fed by a breaker on your AC panel to ensure proper rapid shutdown operation. Please follow the instructions in this video for a safe, Code compliant, and worry free system.
@quackmire
@quackmire 2 ай бұрын
@@Tigo_Flex_MLPE stupid noob question here but my (probably flawed) understanding is that the RS devices at the module level initiate rapid shutdown when the signal from this device is lost, correct? Wouldn't a power failure from the utility then initiate a rapid shutdown of my panels, and subsequently kill my solar array? That seems to be counter to what I'd want in a situation like that, where I'd be depending on my panels to act as a backup? I'm sure I'm missing something, just trying to understand how it all works.
@SaymonPM
@SaymonPM 3 ай бұрын
Does the power that feed the power supply unit that converts to DC supply, need to be from the Solar power or permanent utility power supply? And why?
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 3 ай бұрын
Great question! The RSS Transmitter must be fed by an external 12V/1A power supply fed by a breaker on your AC panel to ensure proper rapid shutdown operation. Please follow the instructions in this video for a safe, Code compliant, and worry free system.
@diegomontez6810
@diegomontez6810 4 ай бұрын
Właśnie planuje zakup TIGO TS4-A-O i nie wiem czy jeszcze jakieś kable musze dokupować czy te co są w module będą wystarczającej długości
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 3 ай бұрын
Cześć! Ogólnie rzecz biorąc, kable w TS4 są wystarczająco długie. Możesz sprawdzić nasze arkusze danych, aby uzyskać informacje na temat opcji zamawiania dłuższych kabli. www.tigoenergy.com/downloads
@savedforever7702
@savedforever7702 4 ай бұрын
Thank you for this video. This is very valuable information for my install. If I'm running two inverters with two strings per inverter, should I have 2 separate RSS transmitter kits? Thanks
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 3 ай бұрын
Excellent question! Since each RSS Core can handle 10 PV conductors, you may only use one RSS Transmitter for both inverters! If you have any questions please contact our support team.
@profispass5746
@profispass5746 5 ай бұрын
Hallo, wo bekomme ich eine Anleitung wie ich am CCA (Cloud Connect Advanced) die Tigo-Optimierer erfassen kann? Mit der App die QR-Codes scannen, funktioniert nicht wenn man nicht weiß was man wo tun soll.
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 9 күн бұрын
Vielen Dank für Ihre Frage. Dieser Artikel beschreibt die Lösung. support.tigoenergy.com/hc/en-us/articles/4471339029395-Commissioning-a-TS4-System-Getting-Started
@christophergill2391
@christophergill2391 5 ай бұрын
Your CCA 24V power supply is labelled "Output: 12 volt 1.25 amp". Why?
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 5 ай бұрын
That is the rated output to the Tigo Access Point(s). Does that rating conflict with your application?
@MrDaggul
@MrDaggul 5 ай бұрын
Hello, is it possible to place the transmitter coils on the positive (red) wire?
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 5 ай бұрын
Our documentation states to use the negative conductors to ensure consistency amongst installations, but the positive conductors may be used if your question pertains to an existing installation.
@steve_787
@steve_787 6 ай бұрын
Multiple orientation question, I have a quote which has 20 panels total. 10 are on one string East facing and then 5 South & 5 North on the other string all with optimisers. Is the north/South string going to be ok? Using a Solis 6kW hybrid inverter. Panels are JA Solar 440w bifacial and I'm in the UK. Cheers
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 6 ай бұрын
We love complex roof geometries like yours, Steve! These are applications where optimization shines, no pun intended. The optimizers will work as hard as they can to harvest as much energy as possible from those modules. Although we do not recommend looping a string over multiple roof faces, the system will still perform well. One concern would be the placement of the Tigo Access Point (TAP) since it is installed onto a module in the center of the array. Since you have multiple strings covering 3 different orientations, we want to ensure the TAP will have a strong signal to reach the other TS4s on their roof faces. Contact our Sales Engineering team for a free TAP Placement review. Worse case, you many need another TAP. support.tigoenergy.com/hc/en-us/articles/4401866316307-Contact-Support
@steve_787
@steve_787 6 ай бұрын
@@Tigo_Flex_MLPE many thanks for the quick reply! So ideally I'd have them all on their own string but could have them on the same if needed 👍 My roof is a little odd as the house was extended but should be able to get the TAP in the middle of the roof and reach all the panels as its all fairly close together. Hard to explain in comment but on main east roof and then the extension to the rear which would have been too wide the keep the new ridgeline below the original ridge height so have a double peak roof at the back, so essentially 4 roof faces (2 north and 2 south). It may be that I have a second invert running the battery so might get them to split anyway but at least I know it's not an issue if I don't. Thanks again and I look forward to generating so sun power soon!
@aleksstriz2414
@aleksstriz2414 6 ай бұрын
Is there a specific distance from solar to transmitter, for it to work properly
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 6 ай бұрын
Great question! For a single transmitter and Core, the total round trip distance of the DC lines must be less than 300 meters. If you use the dual Core Transmitter then this distance is extended to 500 meters. The Tigo Academy TS4 course covers this important design consideration along with other criteria to ensure a safe and lost lasting system. www.tigoenergy.com/tigo-academy
@astro_sun_pv9050
@astro_sun_pv9050 6 ай бұрын
I have the question, Is the warranty void if the optimizer is mounted at the bottom of the panel and on the roof? Thank you for your answer
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 6 ай бұрын
This is a common question and the answer is yes. Our installation instructions explicitly prohibit installing the TS4 with the gland seals facing upwards. This could introduce water intrusion into the device over time. Please visit our Downloads page to find the TS4 quick start guide for your project. www.tigoenergy.com/downloads
@astro_sun_pv9050
@astro_sun_pv9050 6 ай бұрын
@@Tigo_Flex_MLPE Ok, thank you for answering. Greetings
@user-rk8pb2pr5t
@user-rk8pb2pr5t 6 күн бұрын
@astro_sun_pv9050 get away from this product. Many fires started from faulty products. Insurance backed our company and tigo settled as they were wrong. Please look into other products like solaredge or yaskawa. Chint solar and tigo are straight shit.
@tomsunlove
@tomsunlove 6 ай бұрын
Actually! Solar is still a great value under NEM 3.0 in CA! Just add solar with batteries to store any excess solar production in the batteries and avoid sending it to the grid, and use your stored energy to midgate high Time of Use (TOU) rates between 4pm and 9pm and to power your home overnight. I'm quoting solar and battery systems that have less than an 8-year payback and include a 30-year 100% solar parts and labor warranty with roof leak protection. Effectively, producing your own energy at a fixed cost that's 30% to 50% less than the utility $0.36 to over $0.60 per kWh rates that increase yearly at well over 8% per year. We expect CA utility rates to double in the next 10 years. Since 2011 I've personally helped over 1,000 homeowners protect their homes and families against high CA utility rates. Love to help! Tom Semark www.sunlove.us solar and roofing.
@marcneed
@marcneed 6 ай бұрын
Damping, absolute rubbish. EMV creates endless problems. The BNetzA immediately takes such systems out of operation in Germany
@SnarkySolarGuy
@SnarkySolarGuy 6 ай бұрын
EMV- as in using chip cards for payment? I think you may have commented on the wrong video.
@marcneed
@marcneed 6 ай бұрын
absuluter müll das zeug. erzeugt EMV problemem ohne ende. die BNetzA nimmt solche anlagen sofort aus betrieb
@clivebrown400
@clivebrown400 6 ай бұрын
Can I bundle my ground wire for my panel/rail with my home-run? I don't see where there would be any crosstalk there. I need to get that grounding wire across the roof and into my rooftop entry-box.
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 6 ай бұрын
That is acceptable. Thank you for asking!
@Lee-xs4dj
@Lee-xs4dj 6 ай бұрын
So many guys I work with get angry at me for reading manuals and pointing out things they're doing wrong and said "the manual is wrong, I always install it like this". Heated arguments have ensued on many occasions where I just tell them "do what the f___ing manual says to do". Drives me crazy that people think they know better than the engineers that designed the product and wrote the manual.
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 6 ай бұрын
Yes!! Thank you for your RTFM support, as it also keeps the warranty intact!
@MarcusBerger
@MarcusBerger 7 ай бұрын
Why don't your devices work with a Victron charge controller? At least Victron is missing from your manufacturer list. Thank you
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 6 ай бұрын
Thank you for your question! Please use our product request from so that we can begin testing. www.tigoenergy.com/inverter-compatibility#section-request
@massimilianobianchi5078
@massimilianobianchi5078 7 ай бұрын
Vorrei capire ma va collegato anche all'inverter? Oppure bastano i cavi fra i due conponenti e alimentaziine. grazie
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 6 ай бұрын
Grazie per questa domanda! L'ACC e il TAP creano un sistema indipendente. Non è necessario collegare questi due prodotti all'inverter. Si prega di contattare i nostri tecnici di vendita per ulteriori informazioni. +39 055 1987 0059
@tjmooney4181
@tjmooney4181 7 ай бұрын
Do i need a cca and tap for each string of 8 panels i plan to add the ts4 optimiser/rsd to?
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 6 ай бұрын
The TS4-A-O must have a CCA and TAP for full warranty coverage. This allows full system visibility using the EI App and Portal. www.tigoenergy.com/monitoring
@emmanuelpetilo7050
@emmanuelpetilo7050 7 ай бұрын
Is it ok if every transmitter have different main breaker in ac side. I mean is it ok if the followers have different breaker from a leader
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 7 ай бұрын
They leader and followers should turn on and off at the same time. So they should all come off of a single breaker.
@user-vn5uj5hp5j
@user-vn5uj5hp5j 7 ай бұрын
Hi, thanks for the clear videos. I have a question. With 1 CCA and 1 TAP, apart the quantity limity mentioned in the video, can I control the PV panel of two different installation? (the 2 installation are clearly on the same roof, but they belong on two different owner. Thanks in advance for your feedback.
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 7 ай бұрын
Please contact our Customer Success team.
@tjmooney4181
@tjmooney4181 7 ай бұрын
Would it be beneficial at all if i only install one of these on the 1 panel i have that has a shade issue every morning, bringing down the power from my other 7 in the string?
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 7 ай бұрын
You could just install one but it will need the CCA and TAP to have full 25 year warranty coverage. At that point, you may as well install 7 more and have full monitoring on all modules of your array. You will also get reclaimed energy on the modules and the optimizer will reduce module mismatch for the lifetime of the system.
@tjmooney4181
@tjmooney4181 7 ай бұрын
@Tigo_Flex_MLPE great thank you I have a set of 8 in my cart at signaturesolar but didn't know about the other 2 parts required, I'll add them and if the total is reasonable I'll get them otherwise next paycheck hopefully 🙏
@user-rk8pb2pr5t
@user-rk8pb2pr5t 3 ай бұрын
Tigos catch fire. We won't install or service them.
@dogfart8101
@dogfart8101 3 ай бұрын
@@user-rk8pb2pr5t Sounds like you need to watch more videos
@EvV-ny6zd
@EvV-ny6zd 27 күн бұрын
@@user-rk8pb2pr5t Oh is it real? Explain or make an KZbin video to show it or call the news outlet to spread the word. Thanks for warning us.
@user-kk2os8xn9m
@user-kk2os8xn9m 7 ай бұрын
Our power company is asking that we install our rapid shutdown buttons inside of a bubble cover. Is there an option for this with tigos rapid shut down button?
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 7 ай бұрын
We leave equipment selection up to the installer. We do not provide an outdoor rated enclosure for a rapid shutdown initiator.
@user-kk2os8xn9m
@user-kk2os8xn9m 7 ай бұрын
I've got a tigo transmitter and core sitting in my warehouse. It might be an older version, but it doesn't have any indication of black or white markings. If I use it would I be good to just install the core either way?
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 7 ай бұрын
Great question! We recommend swapping that older version with the newer Core that has a black and white side so you can tell the proper orientation.
@Waldoe16
@Waldoe16 7 ай бұрын
Very nice! Would like to see the full installation/comissioning(ATS/inverter/battery). When are the All-in-one systems coming to the USA? The european versions look like a nice option too.
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 7 ай бұрын
Yes, the European stack is pretty slick. We have some new things on the horizon for the US market. Stay tuned!
@nolanbatteryfowarder5932
@nolanbatteryfowarder5932 7 ай бұрын
great!!!
@Waldoe16
@Waldoe16 7 ай бұрын
😂RTFM! I understand Greg 100% and the staff even if I don't work there. The manual goes straight to the point with easy instructions. Installers frequently install the TS4 as if they were microinverters and think there is no need to read instructions. I have seen some youtubers make the mistake too and have issues. I have been educating myself on solar, because I want to make a full install on my own eventually.
@Tigo_Flex_MLPE
@Tigo_Flex_MLPE 7 ай бұрын
Thank you so much!