Channel Membership is LIVE!
2:21
3 жыл бұрын
Пікірлер
@tonymartin8640
@tonymartin8640 6 сағат бұрын
Great video. Still have a question. Does the daikin controller still need to be wired to the unit or can it be removed when the third party thermostat is intergraded? I thought I read that the Diakin controller would need to still be wired to the unit but switched to sub?
@cameronroach2674
@cameronroach2674 4 күн бұрын
Thank you for your videos 🙏🙏
@bosko8897
@bosko8897 7 күн бұрын
Hello, when I try access iTM via network, my web browser via the iTM IP address opens only the "Daikin iTM" image, there is no field for entering the user name and password?
@NavyVetGamer
@NavyVetGamer 11 күн бұрын
I got a Daikin heat pump, and imf*ckimg hate it. This is my first winter, and I found out they don't work 40 and below and I don't have an auxiliary heater so I'm f*cking freezing its 31 outside
@scaffoldedmath
@scaffoldedmath 13 күн бұрын
Schedule still runs when I have schedule off. At 6AM, the temp drops to what is in the schedule (that I can’t delete), even though schedule is set to off.
@Warboy21
@Warboy21 15 күн бұрын
Why would you put into forced fan? You could just put into recovery mode and look for green lights on stats. Especially if you have a job where indoor units aren’t visible.
@RK-hf2un
@RK-hf2un 18 күн бұрын
Hi, I have installed the Banet IP server, and I only get 5 points, any suggestion please? 1-Daikin ITM server control, 2-Enable ITM schedule of operations, 3-Enable ITM auto change over operations, 4-Timed override minutes and 5-System forced off. Thanks
@urbanturbine
@urbanturbine 19 күн бұрын
Are you able to successfully connect this to Google home? I connect it but the only available control is fan speed. İt connects to Alexa and more functions are available but something wrong about google home integration.
@marcellinotjia592
@marcellinotjia592 21 күн бұрын
Great video. Thank you for posting. In Tridium, is there a way to setup the ITM BACnet server to broadcast fan coil points as points and not devices? This way the controls contractor only need 1 tridium device license from the Daikin ITM (not # of fan coil = # of tridium device license required). Thanks in advance.
@deanrobb2993
@deanrobb2993 22 күн бұрын
Great teacher. I learned a lot from your videos
@adrianomuca6784
@adrianomuca6784 24 күн бұрын
Hello . Im a daikin vrv installer. Im interested in daikin start up. Your videos are wonderful and i thank you . Can you post or send me the the video where you do the start up of both old and new vrv start up . Ok the steps i understod because you explain to good. But can you post a video where you do the whole procedure not in theory but pushing the functions . all the procedure step by step. if you have done that can you please send me that video. Thank you
@kreep3r
@kreep3r 26 күн бұрын
thanks again for the education
@manliolasc
@manliolasc 26 күн бұрын
Hi, I have a Madoka controller installed for a FBA ducted unit. My question is: Madoka menu shows heat, temperature, and ventilation icons. I had to install Madoka assitant + setting bluetooth to can switch to cool menu. There is a way to have all icons on Madoka display by itself ? Thanks
@NotOurRemedy
@NotOurRemedy 27 күн бұрын
What if it doesn’t stop blinking??
@sajalchatterjee1439
@sajalchatterjee1439 27 күн бұрын
How can I baying this product, what is price
@tco282
@tco282 28 күн бұрын
Great Video thank you for the help!
@jimmejohn4252
@jimmejohn4252 28 күн бұрын
Where in America are you mate ? I’d love a job with a company like yours
@kreep3r
@kreep3r 26 күн бұрын
who wouldn't 😂 those commercial places require felonies/ drug addiction / tattoos all over your body, also a raging temper
@jimmejohn4252
@jimmejohn4252 Ай бұрын
What does ds2 port 4 do ? Close off the two ghost ports, like blocking zones on the wall controller when u have 8 zone control and only 5 zones?
@jimmejohn4252
@jimmejohn4252 Ай бұрын
Saved us today buddy
@ScottMellor-p2u
@ScottMellor-p2u Ай бұрын
I'm in a new building with 145 small units that need to be controlled 24/7. Temperatures are going into the 40's at night and up to 60 during the day. We have 20 master controllers throughout the building. Of course one side of the building gets hot in the morning and in the other side gets hot. I want all thermostats to respond to the temperature in the room and maintain a 70-72 degree temp. If I set up the schedule on each master with one scheduled setting of say, 7am, On, cool to 70, heat to 72, will all of the navs connected to the masters follow that schedule? Or do I have to set all of the navs to that same schedule? If I have to set all of them, do I have to set the masters first or does it matter? Thank you!
@juniornosa205
@juniornosa205 Ай бұрын
Do you have a WhatsApp channel
@alanm.6096
@alanm.6096 Ай бұрын
Do you recommend a troubleshooting process. My unit doesn’t appear to be heating at the moment. And the BRC1E73 is not displaying any error messages. If the filter was an issue, would it cause a message to display in any way?
@danhdo8233
@danhdo8233 Ай бұрын
where can i buy the isolation valves that meet the spec for Daikin VRV?
@InverterAlways
@InverterAlways Ай бұрын
Most any distributor stocks them.
@jakeeames725
@jakeeames725 Ай бұрын
I have a vrv 4 stuck in t09
@InverterAlways
@InverterAlways Ай бұрын
Kill power for 5 minutes. Power back on. Wait for initialization to complete. Good to go. Sometimes it gets stuck at step 9. Don't know why.
@comdinet
@comdinet Ай бұрын
Hello, I got 2 indoor units. fxsq125a2veb, fxdq40a3veb. 2 came with brc4c151 and 2 with madoka. I can install DKN cloud wifi adaptor on fxdq40 and control two thermostats remotely? The second unit is split unit, can I still use another DKN wifi controller for it? Do i connect it to wall or indoor unit? As of now it's supper annoying, I want remote controller and everything I tried with BT fails miserably with these two madoka thermostats that I have. Other two units at least came with outdated remotes.
@emhast2516
@emhast2516 Ай бұрын
Keep saying get the code I don’t see code😂
@ArnaudBourgeois
@ArnaudBourgeois Ай бұрын
Hi ! I've goy a big "1" displayed at the centre of the screen of my MADOKA (connected via P1P2 to the internal DAIKIN unit) and I'm stuck with this ONE in the center, none of the +/- buttons as well as the centre of the, do not change any thing And idea ?
@InverterAlways
@InverterAlways Ай бұрын
Usually that only happens when the unit doesn't fully boot up. Maybe check wiring on p1p2
@davecoolaircon
@davecoolaircon Ай бұрын
👍
@thecoolguy23
@thecoolguy23 Ай бұрын
So for the high voltage on indoor units if i have only one breaker how i power the rest of the indoor units? Daysi chain too? Im installing a 4 head vrv and i was going to run independent line for each into a secondary panel with 4 15amp breaker
@bjaquez27
@bjaquez27 Ай бұрын
Can we just make the ITM to be a view only option. I know there’s a Master/Slave switch on the itm. If I do this, would it just eliminate auto from the ITM. I think it just make sense to allow the BRC to do the Auto feature and show the differential at the BrC. I understand using the settings but the end user always ends up changing them regardless.
@InverterAlways
@InverterAlways Ай бұрын
It is possible to set up this way. Yes. You'll need to configure additional field settings at every nav though, and then program the itm differently. No need to set to slave though.
@melakukassye1789
@melakukassye1789 Ай бұрын
How can we make correct setting of DIP switch for this specified model?
@melakukassye1789
@melakukassye1789 Ай бұрын
Dear Dana i hope you're doing well ! I am one of your channel follower and a fan. Firstly, i am really greatful about you kind support ! You also helped me out before. I also need your support now. On the Daikin VRV III ...Unit model RXYQ-P9W1B, i was replacing a faulty main pc board. After i did the rewiring and plugged all terminals, when i start the unit it show PJ alarm on the remote diaplay. When i check for the PJ error code It is for 'Faulty field setting after replacing main pc board' Can you please support me on how to configure the new board or can you share me a service manual for the configuration procedure, i couldn't find a right service manual for my specific model on the daikin official website. Thanks, Melaku
@SRI-il2wu
@SRI-il2wu 2 ай бұрын
Bro I need VRV X commissing
@chokolatt8803
@chokolatt8803 2 ай бұрын
I just started learning VRV/VRF systems and your video has the best explanation for Daikin VRV's important settings so far. Thanks a lot and you really earned a like and a subscribe.
@VincentLamantia-z7w
@VincentLamantia-z7w 2 ай бұрын
Want videos on trouble shooting mini splits by daikin
@VincentLamantia-z7w
@VincentLamantia-z7w Ай бұрын
Have a RZQ18PVJU9. Where’s the S2 connector located.don’t see it and the small board has no additional connection places. Please respond
@Gm94.1
@Gm94.1 2 ай бұрын
Hi, Dana. I have a new question about ITM) Can we actually connect 2 pcs. ITM to each other and use webserver to show all the indoor units which connected to both itm ? If its possible are we using D+ D- plus adp terminals ?
@carolgirard3158
@carolgirard3158 2 ай бұрын
Blah blah blah. Just want to k ow how to turn on ac and the dan.
@Gm94.1
@Gm94.1 2 ай бұрын
Hello colleague, i got a error message from out itm. Shows ''A system error has occurred, and “In safe mode SD card failure” and an error dialog are displayed.'' this error. what can i do ? and why this error can occur ? Thanks.
@InverterAlways
@InverterAlways 2 ай бұрын
Kill power. Remove flash card from back. Re install flash card. Apply power. Sometimes they come loose. Hopefully that resolves your issue.
@Gm94.1
@Gm94.1 2 ай бұрын
@@InverterAlways thx Mr. Dana, i will try
@alichtman
@alichtman 2 ай бұрын
Hi Dana. I saw your daikin VRV self test clip and I have the following question: I worked today on my home daikin VRV unit to reset an E3 fault (was due to power outage) and then started a test run which I did not complete (took too long and actually is not really needed as I did reset the E3 fault). Now all units are working fine but I have U3 displayed on the indoor units. What would be the easiest and quickest way to eliminate the U3 ? Will total reset (20 sec) do the trick? If not - I understand that there is a "quick test" mode which takes much less time than the 30-45 minute full test - what is the sequence to activate this "quick test" mode, and will that be sufficient to eliminate the U3? Thanks very much, Arik Lichtman
@InverterAlways
@InverterAlways 2 ай бұрын
Did you replace outdoor board? If you have a flashing green light on nav with active u3 just run the test from outdoor and let it complete. Easiest way. If the nav green light isn't blinking then your code is just an old code probably stored in nav.
@alichtman
@alichtman 2 ай бұрын
Thanks for the reply. Yes the green light was blinking. No, I did not replace anything. I did run the test but after one hour and twenty minutes I stopped it because it was much longer than the quoted 30-45 minutes. I finally had a technician come here. He initiated a SHORT COMMUNICATION TEST, that apparently exists (only tests comm from external unit to the indoor ones). This took just 10-15 minutes and once it ended - the U3 error was gone. He used just 2-3 clicks to initiate this "Short Test". Do you know what click sequence it is? It may come handy if I get the U3 error again in the future
@InverterAlways
@InverterAlways 2 ай бұрын
Hm... not sure what sort of short test he would have been running other than just resetting the internal addressing. Interesting. I'll have to look into this.
@computertech9032
@computertech9032 2 ай бұрын
Sir translate in hindi
@عبدالمجيدالعك
@عبدالمجيدالعك 2 ай бұрын
huge effort are paid from you thank you from Syria
@clarkdimla1628
@clarkdimla1628 2 ай бұрын
Hi Dana, greetings, just want to ask if upon using the ITM maintenance mode, will the system still produce the U4-01 error if the indoor power breaker is turned off but it is in maintenance mode? also what is the main purpose of maintenance mode
@InverterAlways
@InverterAlways 2 ай бұрын
Funny you should ask. I never use maintenance mode. I'm pretty sure you'll still get an error. The only reason from my understanding is to show its in a maintenance mode so users don't get confused when it errors. I would have to intentionally throw some units in and play with it a bit to refresh my memory. 1,000 itm controllers and counting, zero times used it on a job site lol.
@clarkdimla1628
@clarkdimla1628 2 ай бұрын
@@InverterAlways Thanks for the response. Hoping to get a feedback whenever you try it. Thank you for your videos.
@عبدالمجيدالعك
@عبدالمجيدالعك 2 ай бұрын
Hallow it's abdulmjed from Syria and I'm really interested in vrv system, i have a question could any inverter split unit work on vrv odu? and thanks a million for all this effort it's really useful.
@mustafaelhaddad3193
@mustafaelhaddad3193 2 ай бұрын
Hello, the air conditioning symbol does not appear when programming the remote control, i.e. it gives all the options except the air conditioning symbol. Why?
@octavcotet8832
@octavcotet8832 2 ай бұрын
Great video!Many thanks
@shamsheralam8862
@shamsheralam8862 3 ай бұрын
Great, answer..starinded wire for comm wiring
@shamsheralam8862
@shamsheralam8862 3 ай бұрын
Answer: nitrogen purging...but at what pressure?
@Josaysahn3409
@Josaysahn3409 3 ай бұрын
VRV IV compressor replacement.