What a great podcast! When this got assigned by our department training officer I rolled my eyes. Now? I am recommending this to every cop I know. As a former sailor (Gunners Mate) and a 18 year cop? This hit hard. There is so much TRUTH in this podcast.
@abdulosman8742Ай бұрын
Very helpful Thank You very very very much
@roarrrist3 ай бұрын
wait so we cant use this faucet for the hose???
@tewksburydriver86244 ай бұрын
How can you tell what system it is? Does the panel say addressable on it?
@justinives58904 ай бұрын
Incredible
@nubian475 ай бұрын
Well done 👍
@Fredengle5 ай бұрын
here is a question for you as you probably know in new installations anti freeze is frowned upon it seems possilbe that a fire hose can be attached to the sprinkler system so my question to you is could a dry sprinkler system be attached to a fire hose valve to function as a dry hose valve?
@brettrussell16 ай бұрын
do you know how to reset a over the tally limit on a Symplex 4005? Thx
@CaptainGoldberg6 ай бұрын
Time to upgrade systems to Honeywell EBI life safety with our addressable panels.
@AngelMichael6857 ай бұрын
Ωραία έκθεση για το συστήμα ασφάλειας
@pjmichaelsrocksyou8 ай бұрын
Good video
@noahDhe8 ай бұрын
Do you have to notify fire department when you do main drain test?
@angel02547 ай бұрын
No sir your system should be on test and it won’t notify the fire department always have it in test.
@JGregPike8 ай бұрын
Definitely struck a chord. Been at it since '87 and some of the memories are hard. Thank you sir!
@antoinem59018 ай бұрын
I liked when he put trouble on the fire alarm 1:42
@patrickcarroll-m8u10 ай бұрын
Excellent I met Griff years ago and was so impressed i just seen him again at a seminar in Ulster County it was Great
@DH-og5yr10 ай бұрын
Where we are, valve switches, supervisory on the panel, are latching, in that they do not clear when the valve is reopened.
@michaelbarry89823 ай бұрын
Same here, just gotta reset the panel for it to clear.
@Ricka-1711 ай бұрын
🙏💯 great story
@CarlosGuzman-pz1jr11 ай бұрын
Thank you for your time doing this video. More or less, how many sprinklers could be installed by alarm check valve like that ? for K=16 3/4" sprinklerc type? Thank you in advance
@kiltripxv111 ай бұрын
Very articulate, detailed and to the point. Thanks for the upload, earned a sub.
@zaitonyahya4768 Жыл бұрын
Tuah research sdn bhd
@dylann2038 Жыл бұрын
Good video
@WattooZafar-z1m Жыл бұрын
I want one or two days classes of fire alarm installation
@mychannel88098 ай бұрын
Me too
@aztekaa1 Жыл бұрын
Thanks for the video
@sebastiannielsen Жыл бұрын
Of course, if you wire multiple detectors on a "zone", they are not gonna know which one tripped it. But if you have a conventional system, and you wire only ONE detector per zone, you get no problems. If you want to reduce wiring, you can use "zone expanders", which are devices that usually communicate via RS485, that will reduce wiring. Another way to wire it, is room-based. Wire zones so all detectors and pull stations in a room is on one zone. It makes it easy for everyone including firemen, to know where something happened, and once you have visual sight with that room, it will be easy to find out what triggered the alarm. I actually prefer conventional systems for 3 reasons: They are easier to troubleshoot, because anything you do will have an instant effect on the system. As you saw, that detector you removed took a whole minute or two before the panel even knew about it. The conventional reacted in a instant, thats because the current flow in the loop ceased and kinda instantly woke up the system. The second reason, is that its easy to integrate non-firealarm-equipment into zones. For example burgular alarm, you might want to interconnect it with a burgular alarm, either to share reporting channel, or to switch between "Remote mode" and "Local mode" depending on if the burgular alarm is armed or not. With that, I mean, when people are present, it might be stupid to send the alarm instantly to the fire department, since the fire could be dealt with locally. It could just be some failed cooking that wasn't even a fire, someone already at the stove that reacted immidiately when that pot started to smoke. So thats why it could be good to have a system that is "local" when people are present, and "remote" (send a instant alarm to fire department) when the burgular system is armed and the building is clearly empty. the third reason is the vendor lockin. A conventional system can accept fire detectors from any other conventional system. You aren't locked in to one manufacturer of detectors. If you choose a adressable system, you need to purchase everything from the manufacturer of your panel. That could be advantageous in some cases, so you know everything works together, but the disadvantage is that you might have a duct detector that is shipped along with a HVAC system nicely integrated, and then you can't use it because you don't have THAT vendor of panel.
@kevin0086111 ай бұрын
Thanks a lot Sir for sharing your knowledge, Your comment is so valuable and helpful
@DarklordXX904 Жыл бұрын
Insightful
@bobroberts603 Жыл бұрын
Great talk. Can't wait to read the book.
@davejackson3869 Жыл бұрын
whats that test show? i would think the way u test a sprinkler system is to get smoke near a sprinkler head and see if it goes off? im not understanding
@michaelbarry89823 ай бұрын
It shows that the systems is working and water will flow when needed. You can’t really test sprinkler heads in buildings like that because you’re just gonna destroy whatever is in the room.
@curonelectricity Жыл бұрын
I like your video ❤❤❤❤❤
@IanMDent Жыл бұрын
Excellent, excellent, excellent!
@undaya Жыл бұрын
ok.if you wanted to rearrange some piping ( usually around ac unit ) where we shut water off and drain pipe? Sprinkler people really need to get their pipes up and out of the way. You trying to tell me there is no shut off anywhere?
@TheChampionsPath1 Жыл бұрын
Great conversation.
@IsahSafiyanuBichi-b9b Жыл бұрын
Courageous
@johndelaney7533 Жыл бұрын
We recently had an inspection done by a local company and they said our Gauges needed to be replaced because they were older than 5 years. Can you make a video on how to replace the gauges?
@YTviewer118 Жыл бұрын
I'm sure you'd have to get an approved company to replace the gauges, you can't just unscrew and swap them out as the entire system has to be approved and certified to avoid shortcuts..
@Harry_Gurvich Жыл бұрын
Most gauges used on fire sprinkler systems are installed with a "THREE-WAY GAUGE VALVE" (Google it so you can see an image of it). If your gauges have these valves, you can replace the guages without taking the system "out-of-service". Make sure your new water gauges are listed (approved) for usage on a fire sprinkler system. Use teflon tape on the new gauges if they didn't come pre-taped. Don't use pipe dope.
@theelite8569 ай бұрын
Fire sprinkler technician here technically you your self are not supposed to change out the gauges but if you wanted to just make sure you close the valve right before the gauge then you can remove it or even safer you can close the main valve on the entire system and drain it just make sure to call it in to the central the watches over the building
@RaykingMaster Жыл бұрын
This is how test and practice should be done and explain, thanks....
@NicholasDavis-n8o Жыл бұрын
zone system device hs to be returned to normal before reset
@AnaStudent Жыл бұрын
Why can't the water pressure drop down to zero
@julianneheredia3739 Жыл бұрын
Very well done.
@johng5295 Жыл бұрын
Thanks in a million. Great content. Awesome. Very well explained. I couldn't find this explanation--simply put anywhere else. Great teachers are hard to find. Grade: A++💥
@babugandhibose6663 Жыл бұрын
Very useful video thankyou sir 🙏
@layazentman1284 Жыл бұрын
Hi im an electrician from NJ just got my license and really want to learm these sytems and wouldlike your input. I sthere a way I can PM you so we can talk? Thanks
@candiceangotti47292 жыл бұрын
Short and sweet, thank you!
@mumtazawan14212 жыл бұрын
Very good explained. Thank you and, Regards
@leonardoaboy52372 жыл бұрын
Can be the conventional be integrated to addressable? Please advise