Sir is question ko steel handbook ke according karwaya gaya h same question ko class me kya iss method se karne par number cut honge kya sir ????
@civilworld11 күн бұрын
Not steel hand book, code book IS 800: 2007
@venuveeramalla796617 күн бұрын
Le Z/0.3 here 0.3 is constant value ?
@venuveeramalla796617 күн бұрын
Total span length is 16m but RA RB length wsd 6.5you said how??
@venuveeramalla796618 күн бұрын
If both the stresses are different then which value should take?
@civilworld17 күн бұрын
Minimum value
@venuveeramalla796618 күн бұрын
According to code book the value of ISHB thickness of web is 9.1 andISHB [email protected] the value is 9.8 but in code book 10 and 20 ?????
@civilworld18 күн бұрын
Please refer steel table book for channel section and beam section
@venuveeramalla796618 күн бұрын
In the question angle is no there but in code book mentioned certain angles?
@civilworld18 күн бұрын
Please refer steel tables book
@venuveeramalla796618 күн бұрын
Bro in end bearing what ever getting the value of n2 that value is also same should be taken to b value or not
@civilworld18 күн бұрын
Yes
@venuveeramalla796618 күн бұрын
@@civilworld thnq bro🤝🤝
@venuveeramalla796618 күн бұрын
If use bearing and intermediate stiffener same process or not
@civilworld18 күн бұрын
Same procedure
@civilworld18 күн бұрын
#Designofplategirder #Intermediatestiffeners #Endstiffeners #IS800:2007SteelStructures #welded # kzbin.info/www/bejne/gJPEmJmwhJh5m80 You can watch this video
@SohailMd-ox5yj22 күн бұрын
To get like explain the content so start talk something bro
@civilworld22 күн бұрын
Sure bro, thank you 🙏🏻
@Piyushsingh-pf7qrАй бұрын
Design a built-up column consisting of two channels placed toe-to-toe. The column carries an axial factored load of 1500 kN. The effective height of the column is 10 m. Design the lacing also. Assume Fe 415 grade steel. Solve karke batao
But hi = RL + BS But you are using Fs and IS Don't understand what formula you are using
@civilworldАй бұрын
we are finding the missing, have you done practical classes with auto level?
@syedmajidahmed8292Ай бұрын
What is rl
@civilworldАй бұрын
reference point or bench mark or reduced level
@andrewfrumkin9632Ай бұрын
Thank you this saved our job
@civilworldАй бұрын
Welcome
@civilworldАй бұрын
Welcome
@DhyanaKhamarАй бұрын
i guess strength of weld will be 795.35 N and then 0.795 KN
@mdsafiullah1115Ай бұрын
Why have you selected that particular section u need to explain that...
@civilworldАй бұрын
the section which is nearer to Zp required, thats why you have to refer code book.
@aniketgunjal9531Ай бұрын
The maximum path are the means project completion time it’s right
@civilworldАй бұрын
yes
@clementquiver5777Ай бұрын
Sir how do we get Cost slope Rs./day? And in step 7: how do we get (300+450)
@civilworldАй бұрын
cost slope is given in question and in step 7: we took 20-30 normal cost 300 and 20-40 300+150
@clementquiver5777Ай бұрын
@@civilworldthank you sir…and what about the cost slope is not given in the question how to solve it?
@blaze102Ай бұрын
Sir if it was given that the compression flange of girder is laterally unsupported What would be the changes
@civilworldАй бұрын
Web will buckle
@blaze102Ай бұрын
@civilworld sir could you please tell where the design steps will change
@civilworldАй бұрын
@ no need of selection of web and flange if he given the beam section
@blaze102Ай бұрын
Sir , when you were calculating the moment of inertia about z axis why you didn't take the web portion 😊
@civilworldАй бұрын
Taking axis as reference
@blaze102Ай бұрын
Sir please explain how did you find the plastic section modulus Zp
@civilworldАй бұрын
please refer clause no 8.2.1.2 page no 53, IS 800:2007
@c.hanpien5885Ай бұрын
Gross area of outstanding leg Ago=(90-6/2)*6=522
@civilworldАй бұрын
Outstanding leg means which is not connected to the angle
@PentoonzilАй бұрын
Sir, can we take equal angles instead of unequal angles
@civilworldАй бұрын
Yes you can
@PentoonzilАй бұрын
@civilworld thankyou sir❤️
@civilworldАй бұрын
@ all the best
@Bisha_madi_official2 ай бұрын
Lamda formula kaha re bhai Is 800:2007 nhi re bhai 😡😡
@civilworldАй бұрын
In page no 59 clause no 8.4.2.1
@subhrasmitamajumder72412 ай бұрын
Net area of the connected leg (90-18-6/2)* 6 = Just did what the book has...but you should put your brain at least.. 😁
@civilworld2 ай бұрын
sure thanks for the correction next time i will
@civilworld2 ай бұрын
sure next time i will
@sofiyanazneen39192 ай бұрын
This problem is from which standard book ?????
@civilworld2 ай бұрын
ss bhavikati
@kalyandutt9302 ай бұрын
So nice video but do our civil engineering videos like before ones
@civilworld2 ай бұрын
Sure 👍
@lclkvk60992 ай бұрын
Which book are you referring
@civilworld2 ай бұрын
SS bhavikati
@Arikarinku2 ай бұрын
V³ ka formula kya hai sa usko calculate me kaise nikal lega
@civilworld2 ай бұрын
please refer code book
@kalyandutt9303 ай бұрын
Lovely video
@civilworld2 ай бұрын
Thanks for watching 👍👍
@kalyandutt9303 ай бұрын
Super and beautiful presentation done by you ra i am waiting for your more videos do it ❤❤❤❤ by your batchmate
@civilworld3 ай бұрын
thank you so much
@kalyandutt9303 ай бұрын
@@civilworld your welcome
@hemanthakumara70523 ай бұрын
short & sweet ❤❤
@civilworld3 ай бұрын
thank you 👍👍
@pardhubalu-o4p3 ай бұрын
Hi sir excavation is done fully I mean whole area or the size of footing only
@civilworld3 ай бұрын
whole area because, workers need to execute the work for centering and shuttering, and depends on type of soil and clients requirement too.
@pardhubalu-o4p3 ай бұрын
@@civilworld ok sir if the footings are very close to each other we might need to excavate the whole area right sir
@pardhubalu-o4p3 ай бұрын
@@civilworld if footings are maintaining a good space then we will only excavate the footings + pcc area right sir
@civilworld3 ай бұрын
need space for shuttering works and workers
@civilworld3 ай бұрын
Even if footings maintain good space if you excavate whole area it is easy to carry the materials and once soil disturbed you have to compact it well and depends on type of the soil also.
@shakib30833 ай бұрын
Sir k2 value 10 meter 0.084 and 15 also were is in 875
@civilworld3 ай бұрын
available in code book. if there is any errors please follow the procedure
@shakib30833 ай бұрын
@@civilworld Sir my building height is 19m each height floor to floor is 3.800 my wind speed is 39 my ans is 8.76kn it's right or wrong and my category is 3 class b
@civilworld3 ай бұрын
8.76 Kn is basic wind pressure
@HabatOluoch3 ай бұрын
I love the way he teaches
@civilworld3 ай бұрын
Thank you 👍👍
@NitishKumar-g6u6r3 ай бұрын
Thank you sir
@civilworld3 ай бұрын
You’re welcome and thanks for your support to my channel
@badigivamshikrishna49743 ай бұрын
2nd tdb=441.78 kn
@civilworld3 ай бұрын
👍👍👍👍
@KajalKumari-wh4oc4 ай бұрын
Thanku
@civilworld4 ай бұрын
👍👍👍
@kishorraika64114 ай бұрын
thank u so much, all youtubers doing shitty normal qs with all data given, thanks for this solution of this unique Q
@civilworld4 ай бұрын
All the very best and thank you so much for your support to my channel 👍👍
@Tonnymushi-se4oi4 ай бұрын
How to draw graph of this question
@civilworld4 ай бұрын
you can use excel
@adityaverma27974 ай бұрын
sir how you made the diagram if its nit given in question
@civilworld4 ай бұрын
its a practical subject…you have to practice more examples so that you will also easily do
@Venu-nm4ll4 ай бұрын
Why u should not take tf<100?
@civilworld4 ай бұрын
because our section belongs to buckling class b and in table 10 IS:800:2007 code is specified that. Please refer code book thoroughly
@Venu-nm4ll4 ай бұрын
@@civilworld if you have video send me the link how to choose buckling class according to section
@civilworld4 ай бұрын
@@Venu-nm4ll sorry I don’t have separate video. In the video itself I explained
@Venu-nm4ll4 ай бұрын
@@civilworld how to choose buckling class make one video it is useful for us
@Venu-nm4ll4 ай бұрын
Hiw you got LC=200?
@civilworld4 ай бұрын
4x50=200 4 means 4 spans and each span is 50 mm nothing but pitch distance between bolts. Please refer code book thoroughly
@Venu-nm4ll4 ай бұрын
@@civilworldOne boult is removed for end distance am I correct
@PowerHawk-p6k4 ай бұрын
sir how can i find Izz i m unable to do it
@civilworld4 ай бұрын
Section modulus
@christoph9rl7825 ай бұрын
thank you from Zambia 🇿🇲
@civilworld5 ай бұрын
You’re welcome
@PRIYANKAROY-p7f5 ай бұрын
Very helpful video sir
@civilworld5 ай бұрын
All the best 👍👍
@SuhaniChavan-n8s5 ай бұрын
The ans of fwd is 795.3 how u have taken 79.53
@civilworld5 ай бұрын
you can proceed as per your value…follow the procedure
@civilworld5 ай бұрын
You can proceed as per your value…follow the procedure as per video…
@manupurianjali40145 ай бұрын
300 mm is a depth of the secrion Not load.....If ur not aware of it stop doing these videos but don't convey it in wrong
@civilworld5 ай бұрын
Sure thank you so much next I will not do. Admit my mistake 🙏🏻
@SumanBhatt-m4h6 ай бұрын
Sir why did you subtracted wind load while calculating total factored load normal to sheeting?
@civilworld6 ай бұрын
Because in the load combinations are like dead load + live load