MR Balances: How To Level
0:34
28 күн бұрын
ASMR - Sounds of the Lab
4:34
28 күн бұрын
Пікірлер
@pinkypromise111
@pinkypromise111 6 күн бұрын
😳😳😳
@parveenrawat4652
@parveenrawat4652 19 күн бұрын
Administrator user id & password forget how can change interface setting
@parveenrawat4652
@parveenrawat4652 19 күн бұрын
Administrator password forget pls help me
@parveenrawat4652
@parveenrawat4652 19 күн бұрын
Administrator password forget how can change inter. Face setting
@parveenrawat4652
@parveenrawat4652 19 күн бұрын
Forget administrator password pls help
@Leo-uu9bs
@Leo-uu9bs Ай бұрын
I think it would be smarter to first temperate your sample and then put it into the pycnometer
@saraasger8726
@saraasger8726 Ай бұрын
GWP ?
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory Ай бұрын
Good Weighing Practice. Thanks for watching!
@9491deepak
@9491deepak Ай бұрын
Does it measures or shows density at 15C
@poulamibasu3528
@poulamibasu3528 Ай бұрын
Hi, can this be used to measure the density of powder?
@andreaslehmann7477
@andreaslehmann7477 Ай бұрын
It's a bit strange seen people with masks in 2024
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory Ай бұрын
Thanks for watching!
@alvarocortezmartinez5532
@alvarocortezmartinez5532 Ай бұрын
He intentado conectar una impresora nueva P-25 a un Karl Fischer V20, pero no la reconoce y no permite instalarlo. En conexión sale PnP. ¿Qué puedo hacer o cómo puedo configurar la impresora para que la reconozca el equipo?
@abdoulnasserseynimamoudou4423
@abdoulnasserseynimamoudou4423 2 ай бұрын
C'est quoi le mot de passe du service ?
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory Ай бұрын
Thank you for your message, please ask a local representative. Contact details can be found at www.mt.com under "Contact Us".”
@basarabiadenord5445
@basarabiadenord5445 2 ай бұрын
Ehh, I want one of theese😅
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory Ай бұрын
Thanks for watching!
@ehsanmirsharifi25
@ehsanmirsharifi25 2 ай бұрын
Very educational. Thank you.
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory Ай бұрын
Thanks for watching!
@ZyroRifki
@ZyroRifki 2 ай бұрын
❤❤
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory Ай бұрын
Thanks for watching!
@ZyroRifki
@ZyroRifki 2 ай бұрын
❤❤❤❤😊😊
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory Ай бұрын
Thanks for watching!
@dickyrobians217
@dickyrobians217 2 ай бұрын
Why 158?
@MuhammadAsif-ru5mh
@MuhammadAsif-ru5mh 2 ай бұрын
what is the reason to hole in a lid of sample pan and refrence pan
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 19 күн бұрын
The hole in the lids allow the defined in the DSC furnace to enter the curcible. With a sealed lid, there would be a self generated atomsphere inside of the crucible.
@dr.luthfi3418
@dr.luthfi3418 2 ай бұрын
How to import the plot data file? As we don't have DSC testing equipment in our university, I sent DSC samples to be tested externallly using Mettler Toledo DSC 1. They sent me result files text data format .txt file. When I imported them using Star e software, it did not work. I used file import ANSI.
@Argonaute93
@Argonaute93 2 ай бұрын
🤩
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory Ай бұрын
Thanks for watching!
@bunganurannisa4598
@bunganurannisa4598 2 ай бұрын
Why does pH meter calibration start with pH 7 buffer then followed by pH 4 buffer and then pH 10 buffer? Can the buffer order be randomized (starting from pH 4-7-10 or 7-10-4)?
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 19 күн бұрын
Mettler Toledo pH meters feature automatic buffer recognition for predefined buffer groups. This allows users to perform calibration without following a specific order for the pH buffers. For example, when conducting a three-point calibration using buffers 4, 7, and 10, you can begin with any buffer and calibrate in any sequence you prefer.
@cherifdiallo7122
@cherifdiallo7122 3 ай бұрын
Bonjour s'il vous plaît avez-vous votre page en français ?
@christopher3330
@christopher3330 3 ай бұрын
Just an advertisement for Mettler Toledo. No actual information.
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 3 ай бұрын
Thanks for watching!
@nitamkumartayade1403
@nitamkumartayade1403 3 ай бұрын
Thank you..
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 3 ай бұрын
Thanks for watching!
@behzadkalantari6133
@behzadkalantari6133 3 ай бұрын
🙏🙏🙏🙏🙏
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 3 ай бұрын
Thanks for watching!
@ajaymohan879
@ajaymohan879 3 ай бұрын
Wish i worked with you guys....
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 3 ай бұрын
Thanks for watching!
@chuckaholicpunk
@chuckaholicpunk 3 ай бұрын
What is that small grey cone called??
@carolinanaranjo9264
@carolinanaranjo9264 3 ай бұрын
hola, he revisado la guía de su web, pero no menciona nada sobre frutas deshidratadas. Cuál es el peso recomendado para usar como muestra y la temperatura? muchas gracias
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 2 ай бұрын
@@carolinanaranjo9264 Gracias por su mensaje. Por favor, consulte con un representante local. Los datos de contacto se encuentran en www.mt.com en la sección "Contáctenos".
@MatheusPereira-xy9so
@MatheusPereira-xy9so 3 ай бұрын
Could it be used to automatic pipette solvents into a flask instead?
@manojmodi414
@manojmodi414 3 ай бұрын
Thank you very much for information and technology
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 3 ай бұрын
Thanks for watching!
@debashisbose6467
@debashisbose6467 4 ай бұрын
where is PDF link to download?
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory Ай бұрын
Hi, you have to click either the second or third link in the description to download.
@NerdAndProudOfIt
@NerdAndProudOfIt 4 ай бұрын
Very interesting!
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 3 ай бұрын
Thanks for watching!
@NerdAndProudOfIt
@NerdAndProudOfIt 3 ай бұрын
@@METTLERTOLEDOLaboratoryof course! 👊🏻
@manojmodi414
@manojmodi414 4 ай бұрын
Thank you for automation
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 3 ай бұрын
Thanks for watching!
@СветланаТуркина-д6я
@СветланаТуркина-д6я 4 ай бұрын
Thanks a lot ❤
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 3 ай бұрын
Thanks for watching!
@bltnbros122
@bltnbros122 4 ай бұрын
1) hydrometer (quick measurement, but a lot of sample and glass is very fragile). 2)vpycnometer (accurate, but a lot of sample, time consuming and skill opertor is needed) 3) Digital density measurement
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 3 ай бұрын
Thanks for watching!
@jb-eu6jh
@jb-eu6jh 4 ай бұрын
Is it possible to connect a 2d scanner to this
@MrScorpioAngel
@MrScorpioAngel 4 ай бұрын
nice demonstration
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 3 ай бұрын
Thanks for watching!
@marcusharrigan6879
@marcusharrigan6879 4 ай бұрын
OK.
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 3 ай бұрын
Thanks for watching!
@BB351
@BB351 4 ай бұрын
How does the SMART Check connect to a Laptop?
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 3 ай бұрын
PipetteX is how you record and access SmartCheck verification results on a laptop. It works with SmartCheck to assign test results to a specific pipette. You can also use PipetteX to change the measurement tolerance. If pipettes are serviced with Mettler Toledo Rainin pipette service, calibration certificates also get automatically stored in PipetteX. It’s a 555MB download, and you can find it at www.mt.com/global/en/home/products/pipettes/pipette-management/pipettex-pipette-asset-management.html or check this video: How to Use PipetteX Software for SmartCheck Pipette Verification - kzbin.info/www/bejne/rqWTeJSldpl2obc
@9491deepak
@9491deepak 4 ай бұрын
We are looking for Benchtop top pH meter for our lab , It needs to be robust because it needs to work well with polymer based fluid , concentrated acids and surfactant and solvents based solution. Which probe should be order
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 4 ай бұрын
Dear @9491deepak, We have standard, advanced and excellence level benchtop meters to choose from. We also have specialist pH sensors for measuring pH in solvents (see our white paper on pH of organic solvents), surfactants (see application note on measuring pH in Shampoo), conecentrated acids (sensors with HA glass membrane that show minimum alkali error and acid error) and polymer based fluids (sensors with SteadyForce reference system for viscous non-aquesous samples). For a detailed recommendation and specifications, contact our pH competence and support center at [email protected]
@ferrumferrum9581
@ferrumferrum9581 5 ай бұрын
Great!
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 4 ай бұрын
Thanks for watching!
@PaulinaHernandezYanez
@PaulinaHernandezYanez 5 ай бұрын
If the same kit is used for multiple balances at multiple locations, how far in advance does the kit need to be near the testing balance for temperature stabilization?
@hattricksprospecting1769
@hattricksprospecting1769 5 ай бұрын
I would love to be sponsored with a lab to use one of these
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 4 ай бұрын
Thanks for watching!
@무즈-p7o
@무즈-p7o 5 ай бұрын
Thank you so much! This is very helpful ❤
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 4 ай бұрын
Thanks for watching!
@yonesalbaden8344
@yonesalbaden8344 6 ай бұрын
Thx
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 4 ай бұрын
Thanks for watching!
@ahmedkeshk2410
@ahmedkeshk2410 6 ай бұрын
Hello If you can tell me that I have a sample of filler masterbatch I need test temp. Time. Beginning temp I test on halogen device
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 4 ай бұрын
Dear Customer, Please find all moisutre analysis in plastics realated topics here: www.mt.com/us/en/home/library/applications/laboratory-weighing/analysis-of-moisture-content-in-plastic-pellets.html downlaod the method collection to get a method recommendation for several samples. If you need more detailed information get in contact with our local experts!
@ahmedkeshk2410
@ahmedkeshk2410 6 ай бұрын
Thanks I have a question what ia temp at beginning of test Is it room temperature or you fix it at 105 then you start....
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 4 ай бұрын
The behavior depends on the moisture analyzer model. Normally the determiantion starts at room temerpture. It can be higher if two samples are measured directly after each other and the heat from the first measurement is still in the system. With our moisutre analyzer HX204 it's possible to define the start temperture sing the "preheating" funtion which is a method parameter, with the moisutre analyzer HE53 this function is not available.
@drhelper
@drhelper 6 ай бұрын
Thank you so much. This is a lifesaver.
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 4 ай бұрын
You're welcome! Thanks for watching!
@zarinskie
@zarinskie 6 ай бұрын
Здравствуйте, не могли бы подсказать, что надо делать если pH meter не читает значения pH и вместо этого показывает - - вместо значений?
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 4 ай бұрын
Dear @zarinskie Проверьте, все ли настройки в измерителе выбраны правильно. Закрепите соединения. Измеритель pH по сути является потенциометром, преобразующим сырые значения мВ в единицы pH и может показывать ---- пустые показания, если показания pH выходят за пределы диапазона измерения, например, измеритель pH может иметь диапазон pH от -2 до 20 pH. Если значения выходят за пределы диапазона измерения, то измеритель покажет пустые показания. Для получения помощи в устранении неполадок, пожалуйста, свяжитесь с нашим центром поддержки и компетенции по pH по адресу [email protected]
@zarinskie
@zarinskie 4 ай бұрын
@@METTLERTOLEDOLaboratory Спасибо за ответ! Оказывается проблема была в том, что электрод изнутри высох частично и нужно было залить его KCl и освежить :)
@SiberiaBloom
@SiberiaBloom 6 ай бұрын
Hi, can you recommend the best way to reactivate DMi141-SC electrodes? and another thing is our electrode started to show 420+mV potential in AgNO3 0,1M solution, instead of 250-350, so grath started to be written in jumps. What can be the case?
@METTLERTOLEDOLaboratory
@METTLERTOLEDOLaboratory 2 ай бұрын
@SiberiaBloom The following can be done to regenerate a DMi141-SC electrode: 1.The silver ring can be polished (cleaned) using: 1.Wetted aluminum oxide powder 2.Emery cloth for jewelry polishing 3.Toothpaste on a tissue 2.Fluctuations in the read mV signal often occurs due to a blocked diaphragm in the reference junction. Depending on the nature of the agent that blocks the diaphragm, the following cleaning solutions are available: 1.Sulfide contamination: immerse electrode with diaphragm in a 8% thiourea in 1 M HCl solution for 1 hour under stirring 2.Protein contamination: immerse electrode with diaphragm in a 5% pepsin in 0.1 M HCl solution for 1 hour under stirring 3.Silver chloride contamination: immerse electrode with diaphragm in a 10% ammonia solution for overnight, then rinse and soak the electrode with diaphragm in dilute nitric or sulfuric acid for one hour.