R422D, The R22 Replacement
4:56
12 жыл бұрын
Superheat & Subcooling Overview
3:34
12 жыл бұрын
Testo Digital Refrigerant Manifolds
3:57
Silver Solder Rings - HVAC
1:02
12 жыл бұрын
Heat Pump Manifold and Gauges
1:48
12 жыл бұрын
White Rodgers Thermostat Install
4:47
The Importance of Vacuum Pump Oil
2:17
Replacement Refrigerant R422D
2:27
12 жыл бұрын
Пікірлер
@joseguillermovargasmoyorga1983
@joseguillermovargasmoyorga1983 2 ай бұрын
Donde puedo conseguir en Bogotá Colombia y q precio tiene gracias
@collegestatistics
@collegestatistics 2 ай бұрын
Impossible to figure out! I just wanna put it in manual mode!
@ezramamiye5522
@ezramamiye5522 2 ай бұрын
You’re video is perfect
@waltercastro2015
@waltercastro2015 5 ай бұрын
I would suggest find R22 refrigerant online. Buy it, yes it is expensive but not too expensive as to replace the entire system. Whatever remains keep it for future usage and until you ac breaks. Then you have no choice.
@Himothy_xx
@Himothy_xx Жыл бұрын
Where do the blower motor harness go?
@aaronclark1599
@aaronclark1599 Жыл бұрын
Does it require an oil change
@dnell6854
@dnell6854 2 жыл бұрын
What seals are you referring to replace?Thanks!
@Марусякожаева
@Марусякожаева 2 жыл бұрын
*Works well in my home **Fastly.Cool*
@cecilburgess241
@cecilburgess241 2 жыл бұрын
Do you know of anyone that does this in Sun City Az area?
@sanitariosferreteria5849
@sanitariosferreteria5849 2 жыл бұрын
habra algo en castellano- español
@jamesjazzy8040
@jamesjazzy8040 3 жыл бұрын
Wonderful.... but I don’t have that machine which looks like it costs over $10,000.....
@waldo-ot6ul
@waldo-ot6ul 2 жыл бұрын
You can rent it from home depot or lowes
@natec9420
@natec9420 2 жыл бұрын
You get it free at Home Hardware when you buy the insulation there
@ThanksAgain
@ThanksAgain 3 жыл бұрын
It's great-- except you can't get the material at the same Home Depot you can get a machine. Distribution system is a hot mess.
@LubaLuba1
@LubaLuba1 3 жыл бұрын
Question to the smart professional man if I leave my AC running while evaporator is frozen will I lose Freon / R22??
@12345678972041
@12345678972041 3 жыл бұрын
Are there any tax incentives for taking an old (but working) R22 unit out of service and replacing it with a new one (R410)?
@viclee7800
@viclee7800 3 жыл бұрын
Hi, if I'm out off R22, can I just drop in R422 as add on??
@viktorsto
@viktorsto 4 жыл бұрын
Hi , I got broken VR8200A2363 . Can I replace it by your universal one ?
@philg4116
@philg4116 4 жыл бұрын
This guy is the pulsating brain of Honeywell Corp, wearing the official service shirt to avoid scaring people too much.
@jerryharvell3938
@jerryharvell3938 4 жыл бұрын
Hello people I have several questions about converting a R22 system to any other new refrig type. Q1. Must I have the compresser replaced in order to convert the system? Been told this must be done I have. 3.5 ton goodman scroll compresser condensing unit. The compresser was replaced 2 years ago. Q2. Must the line set be replaced as well? Q3. My goodman air handler says R22/R410 compatible. 3.5 ton as well Q4. How much approx should I expect to pay for this service? Thanks
@dallas69
@dallas69 5 жыл бұрын
No Converting a R22 system to R422D 1) I read 95% polyolester oil (POE) and 5% mineral (old R22 oil) is OK. 2) POE oil is hygroscopic that means the oil should be pumped in and the oil can should not be opened to the air. But great work this is almost unknown by local Hvac companies here in DFW Thank You As a Hvac engineer Open compressor via removing the valve stem. Insert a rubber tube down to the bottom of the compressor Suck out 95% the old R22 mineral oil. Pump in new POE oil Re install valve stem. Purge with dry N2. Vac the system Charge with R422D. Pulling the compressor is not necessary. POE is a better oil for your HVAC system. If your going to change out R22 then it is better to suck out 95 to 100% of the old R22 mineral oil and start fresh with POE.
@Tim_Takacs
@Tim_Takacs 4 жыл бұрын
Why do it when you can use this refrigerant or RS44b which is also a direct drop in?
@ryanmalin
@ryanmalin 2 жыл бұрын
I've got many rack systems and air conditioners running with r422d and mineral oil and so far no issues. Retrofit was carried out in 2016 and its been 6 yrs with mineral oil.
@bigbeef8935
@bigbeef8935 5 жыл бұрын
If you wanna know how to do this properly, watch the episode of this old house. THIS IS Not correct and that cardboard will burn your house down wtf
@CR67
@CR67 Ай бұрын
At this point,LED light makes that obsolete, but, I am not impressed by cardboard, because cardboard deteriorates.
@marcodeluca4068
@marcodeluca4068 5 жыл бұрын
don't believe this its another hwy robbery
@rickysharma5076
@rickysharma5076 6 жыл бұрын
*>>>**t.co/4fgWByc6sX** I love this thermostat it learns my daily schedule, tracks when I change the temperature then adjusts itself accordingly, it saves me money on electricity with eco mode and it also lets me know what temperatures are most economical through the day! Love the modern design and easy installation! Really worth the money!*
@emilygg5033
@emilygg5033 6 жыл бұрын
More and more insolation
@emilygg5033
@emilygg5033 6 жыл бұрын
More fkin money why no make adobe homes cheap in better
@kmreedN205
@kmreedN205 6 жыл бұрын
Excellent textbook procedure. Refreshed my skills
@victorguerra9232
@victorguerra9232 7 жыл бұрын
I dont understand,why in the fuck if they new the r22 was gonna be replaced,,,,,why in the fuck they just make 2 or 3 refrigerant instead of 20 different kinds,,,then these techs use all kids of different ones,,,and to cylinder,, all types of different refrigetants,,,I sometimes have to go buy a new cylinder jug for this bullshit,,,fucking epa,,,,do ur fucking job!!!and get rid of all these different types and stick to 2 or 3,,,,fucking dumb assess!!!get paid to sit on yall ass and make things hard for us,,,and customers and the environment!!!so what is yall purpose ??????these motherfickers need to be investigated cause,,,there doing more harm than good!!!!
@TonchyShultz
@TonchyShultz 7 жыл бұрын
Very good explanation guys! Thx for sharing! :-)
@ThreePhaseHigh
@ThreePhaseHigh 7 жыл бұрын
Reclaim the R 22 pull a good vacuum use the pressure temperature chart for the new refrigerant and get down the road. Time a wasting.
@craigpurdom1727
@craigpurdom1727 5 жыл бұрын
ThreePhaseHigh with you on that one
@williamrodriguez5070
@williamrodriguez5070 7 жыл бұрын
why any time some one is talking about how to get super heat never ...never shows where to locate the temp probes on the suction or discharge line ..you know why ? because all of those guys are a bunch of fully of shit.
@notanewbie1718
@notanewbie1718 7 жыл бұрын
What we need is more EPA rule changes so that we need 15 different refrigerants, not just 2 or 3.
@frederick_electrick
@frederick_electrick 7 жыл бұрын
The 90s called and want their denim back.
@dannygoodtimes9779
@dannygoodtimes9779 7 жыл бұрын
#StopDenimOnDenimViolence
@trackforcemg5779
@trackforcemg5779 8 жыл бұрын
Can you put in the nu 22b without pulling out the old r22??
@geoffhoweth
@geoffhoweth 7 жыл бұрын
Has it been done Yes.... But EPA regulations forbid mixing of any types of refrigerants.
@whitesheatingairappliancer7101
@whitesheatingairappliancer7101 8 жыл бұрын
nice video, I will check my suppliers.
@CougarLand
@CougarLand 8 жыл бұрын
4:40 Vents put in like that looks like it will let stuff in the corners. 4:49 Good Lor... do not use cardboard around fixtures, there are products for that.
@menendezgilbert
@menendezgilbert 8 жыл бұрын
Yea, so professional and proper. Nice and clean. I like to see him be so proper in his procedure in 95 degree temperature with 80% humidity, along with his phone ringing for bitching customers. Taking care of 10 other things in that same day. If new people getting in to this line of work think that this is how it really is in the real world. Huh, there going to get a full eye opener.
@jdub7771
@jdub7771 8 жыл бұрын
Exactly! Lol
@MrAgatto2
@MrAgatto2 5 жыл бұрын
amen...
@Dadolphinsmakemecry
@Dadolphinsmakemecry Жыл бұрын
Lol GD RIGHT
@gtilapias
@gtilapias 8 жыл бұрын
is that true that aticat insulation should not be used in an empty attic? in other words, in order to use aticat blown insulation you have to have prior old insulation in the attic.
@CougarLand
@CougarLand 8 жыл бұрын
Answer = NO
@aliaslost2774
@aliaslost2774 8 жыл бұрын
Cougar Land jacob bennett I just had this stuff sprayed in my attic. There was a huge hole from where my water heater vent goes into the attic. The insulation fell into my kitchen area. Now my family is getting sick! It feels like our throats are closing up and our sinuses hurt! Are we gonna be alright?
@vatossan
@vatossan 8 жыл бұрын
I hate Florida so much. its a hell hole.
@SovereignTroll
@SovereignTroll 5 жыл бұрын
Why?
@Vinces618
@Vinces618 8 жыл бұрын
ALSO IF YOU HAVE A LEAK IN YOU SYSTEM YOU HAVE TO FILL EVERY YEAR IT IS BETTER TO FIND THE LEAK IT ISNT HARD SHOULD BE OIL RESIDUE WHERE HAS BEEN LEAK CLEAN AND PATCH IT,, BUT YES THEY DO HAVE STUFF THAT CAN SEAL LEAKS,, I WOULDNT PUT ANYTHING IN SYSTEM BUT THE REFRIGERANT BUT THEY SAY IS SAFE
@VinierrhinoGaming
@VinierrhinoGaming 5 жыл бұрын
OK THANKS FOR YELLING AT ME I NEEDED THAT OK THANKS BYE HAVE A NICE DAY
@Vinces618
@Vinces618 8 жыл бұрын
ANY BLEND YOU SHOULD CHARGE AS lIQUID,, I USUALLY CHARGE LIQUID WITH EVERYTHING, DEPNDING HOW MUCH IS NEEDED IF PUTTING IN R22 OR A NON BLEND OF COURSE YOU SHOULD CHARGE VAPOR , BUT IF NEED TO DUMP IN ALOT CHARGE LIQUID, JUST DO A LITTLE AT TIME DO NOT FLOOD COMPRESSOR F COURSE
@Hwoodification
@Hwoodification 8 жыл бұрын
Dan,...I beg you to look at NU-22. Why would you use something that is not even close on your t/p chart? my .02
@olivershagnasty7704
@olivershagnasty7704 8 жыл бұрын
407C plz...thank you.
@Tim_Takacs
@Tim_Takacs 4 жыл бұрын
NU-22 will eat orings and seals on semi hermetic and hermetic/scroll compressors. NU-22 is garbage
@ahmadzazai5048
@ahmadzazai5048 9 жыл бұрын
can you please demonstrate the ignition trial timing set-up?
@Jiwwww
@Jiwwww 9 жыл бұрын
Great presentation.
@ZuffaLtdDanaWhite
@ZuffaLtdDanaWhite 10 жыл бұрын
no flux?
@myviews469
@myviews469 10 жыл бұрын
I don't have a heat pump I live in NYS but I do have a small leak which requires me to add Freon every spring or summer. Question is there a clog up liquid I can use?
@memoperaza407
@memoperaza407 10 жыл бұрын
Are this compound gauges?
@butchtwoseven8890
@butchtwoseven8890 11 жыл бұрын
hold on a minute, well about 1 minute and 11 sec. He evacuated the system before removing the old refrigerant? then he is going to recover the old gas, johnStone better re-do this procedure...
@josephrostkowski8631
@josephrostkowski8631 Жыл бұрын
Good catch 😂this is an infomercial funded by epa lobbies 😮! Wait til we go back to propane base refrigerants 😮 HISTORY HAS A STRANGE WAY OF REPEATING ITSELF 😮MAYBE WILLIS HAD IT RIGHT TO BEGIN WITH?
@voncobain
@voncobain 11 жыл бұрын
those are some old school micron gauge!
@TheChaseair
@TheChaseair 11 жыл бұрын
The head pressure was much higher... 300 on a 96 degree day? Wowsers... Subcooling was high, suction pressure normal.... Is this ok? Superheate would tune in but wow... High head and subcool
@jdub7771
@jdub7771 11 жыл бұрын
That's the sexiest recovery cylinder I've ever seen!
@newstart49
@newstart49 11 жыл бұрын
R422d is a low to med temp refrigerant. Isn't residential classified as high temp?