Running into an issue, I can copy .mer file to HMI but won’t load, says unable to load, idea??
@SYPHOANG
@SYPHOANG 22 сағат бұрын
@LastMooseStanding: It might be from the HMI firmware or the resolution or the version of the HMI (Standard or Performance).
@ricamonta899
@ricamonta899 3 күн бұрын
Will this let the panelview 800 hmi communicate with control logix plc?
@SYPHOANG
@SYPHOANG 2 күн бұрын
@ricamonta899: I have not tried it but I think it should be able to.
@ricamonta899
@ricamonta899 2 күн бұрын
@@SYPHOANG ill give it a shot, I know I might have to do some logic on the controller side.
@rangeralone6181
@rangeralone6181 4 күн бұрын
em khởi động lại và ấn giữ vào màn hình mà ko vào đc trang tool như anh ạ, có phải cắm dây mạng vào không anh
@SYPHOANG
@SYPHOANG 4 күн бұрын
@rangeralone6181: Tôi cũng mắc lỗi tương tự ngay lần thử đầu tiên. Bạn chỉ cần nhấn mạnh hơn một chút và giữ lâu hơn một chút.
@rangeralone6181
@rangeralone6181 4 күн бұрын
anh ơi ! cho em hỏi xíu ạ, em có cái màn hình X2 Pro 15 , nhưng em muốn vào kiểm tra IP vs xem có những file ảnh nào để load thì làm sao ạ, cái hiên jtaij của em không có chương trình trong màn hình , chỉ có ảnh , nhưng khong hiểu sao em khởi động lại trên HMI mất 1 Line không hiên thị ạ
@SYPHOANG
@SYPHOANG 4 күн бұрын
@rangeralone6181: Unfortunately I have not experienced it before.
@tanachaiphoset3451
@tanachaiphoset3451 5 күн бұрын
Thanks ,my friend good VDO then can helping me for setting.
@SYPHOANG
@SYPHOANG 4 күн бұрын
@tanachaiphoset3451: Happy to help. Thank you for subscribing to my channel.
@ibrado900
@ibrado900 6 күн бұрын
thank you sir
@SYPHOANG
@SYPHOANG 4 күн бұрын
@ibrado900: Thank you for subscribing to my channel.
@ansonkiek6471
@ansonkiek6471 7 күн бұрын
Hi why some only trigger and stop in row 1k or sometimes in 2k ?
@SYPHOANG
@SYPHOANG 6 күн бұрын
@ansonkiek6471: 1k, 2k ? Would you please explain it a bit more?
@ansonkiek6471
@ansonkiek6471 6 күн бұрын
@@SYPHOANG my data write until 2k then stopped for example file created on 7/31 , I see only store until 2/9 and stopped working
@SYPHOANG
@SYPHOANG 6 күн бұрын
@ansonkiek6471: I still don't understand what do you mean for 2k? is 2k a year? is 7/31 a date? do you have data logged into an SD card? or the HMI internal memory? if it's logged into the HMI internal memory, it might be full and stop logging.
@ansonkiek6471
@ansonkiek6471 6 күн бұрын
@@SYPHOANG 2k is data store in CSV row , and I use usb store my CSV data I see my CSV file in pen drive created in 7/31 and CSV last recorded only until2/9 how possible stop due to hmi internal memory full ?
@SYPHOANG
@SYPHOANG 4 күн бұрын
@ansonkiek6471: I guess 7/31 is July 31st and 2/9 is February 9th? You might need to check your "trigger" tag.
@quoit99training83
@quoit99training83 9 күн бұрын
Thank you 🙏 for great plc videos
@SYPHOANG
@SYPHOANG 9 күн бұрын
@quoit99training83: Thank you for your comment and your support to my channel.
@luctranvan4273
@luctranvan4273 10 күн бұрын
Em có làm đến đoạn Discover thì upload success nhưng không thấy PanelView 800 được upload vào project ạ.
@SYPHOANG
@SYPHOANG 10 күн бұрын
@luctranvan4273: Cảm ơn bình luận của bạn. Vui lòng xem video bên dưới để biết hướng dẫn mở .cha file đã tải trên Connected Component Workbench. Nếu nó hữu ích và bạn thích nội dung kênh của tôi thì một "super thanks" sẽ là cách tuyệt vời thể hiện sự ủng hộ của bạn đối với kênh của tôi. kzbin.info/www/bejne/fYechKNubcyDgZY
@kenneym2003
@kenneym2003 10 күн бұрын
Exactly my problem. brilliant, easey to follow .System now running. Thanks for the Help
@SYPHOANG
@SYPHOANG 10 күн бұрын
@kenneym2003: Glad it helped!
@bryanfrancisco-t7x
@bryanfrancisco-t7x 11 күн бұрын
This will help me in todays project. Thanks
@SYPHOANG
@SYPHOANG 10 күн бұрын
@bryanfrancisco-t7x: Happy to help!
@GeekendZone
@GeekendZone 14 күн бұрын
Can use a DNS in this Allen Bradley PLC to acces fron the Outsite of the local network?
@SYPHOANG
@SYPHOANG 12 күн бұрын
@GeekendZone: Thanks for your comments but I am not familiar with DNS, never tried it before.
@ghuy6073
@ghuy6073 14 күн бұрын
Hi anh, anh có thể cho em hỏi là dòng PM5300 cụ thể là PM5320 có hỗ trợ Ethernet Modbus TCP/IP nhưng khi em thử kết nối với modscan thì nó báo lỗi "Modbus Exception...". Anh có từng gặp lỗi này chưa ạ :3
@SYPHOANG
@SYPHOANG 12 күн бұрын
@ghuy6073: Thanks for your comment. I think it should come with Modbus TCP. There are a few things you might want to check. First, make sure you have the right register mapping. Second, slave ID might matter. Make sure you call out the correct slave ID on your master device. Third, be specific on the register length or count. Do not set the length too long or pick up too many registers. If the registers are not available at the device and you are trying to pick them, it might give you errors too. Good luck!!!
@PLC-79
@PLC-79 16 күн бұрын
your english very good. wait for more clip about rockwell
@SYPHOANG
@SYPHOANG 15 күн бұрын
@PLC-79:Thank you for your kind words and your support to my channel.
@plc24_max10
@plc24_max10 16 күн бұрын
Thank you, a great video! But I have a question: After recording data on the SD card, can I remotely access it through Ethernet ( I am using Compact Logix L27erm)?
@SYPHOANG
@SYPHOANG 16 күн бұрын
@plc24_max10: Unfortunately, I don't think it is possible.
@carolinadiaz0126
@carolinadiaz0126 17 күн бұрын
How can I export the alarms/events by Active control X to a USB flash drive?
@SYPHOANG
@SYPHOANG 17 күн бұрын
@carolinadiaz0126: What you need is "Audit Trail" and "CSV Export". kzbin.info/www/bejne/aHXPmZyDoc1ojNksi=ztyJBiZ4N5aUBfxi kzbin.info/www/bejne/p4rEpZWto7l3sKcsi=0b6gVPKDGYbyVgJs If you like the content of my videos, a "super thanks" at the lower right should be a great way to show your support to my channel. Thank you.
@kurtklingbeil6900
@kurtklingbeil6900 19 күн бұрын
soundtrack is annoying and obnoxious
@SYPHOANG
@SYPHOANG 18 күн бұрын
@kurtklingbeil6900:.
@mdlutforrahman4544
@mdlutforrahman4544 20 күн бұрын
dear, i have download ME TRANSFER UTILITY. but now need sourch file. please you help me???
@SYPHOANG
@SYPHOANG 18 күн бұрын
@mdlutforrahman4544: Are you trying to modify the existing HMI application (.mer file) on the HMI? ME TRANSFER UTILITY is a tool for you to download/upload an HMI runtime/application to/from an HMI from/to your computer. An .mer file is for an actual HMI only. If you need to work on it. You will need 2 more pieces of software. "FactoryTalk View ME Application Manager" to "restore runtime application" and "FactoryTalk View Studio ME" to work on the restored HMI application.
@PauloFonseca-z5s
@PauloFonseca-z5s 23 күн бұрын
TANKS you save me
@SYPHOANG
@SYPHOANG 23 күн бұрын
@PauloFonseca-z5s: Glad it was helpful.
@elianousdu30
@elianousdu30 25 күн бұрын
In what type i have to format my usb stick to make it work with a Panel view Plus 7 ? And is the path always the same ? Thank you !
@SYPHOANG
@SYPHOANG 25 күн бұрын
@elianousdu30: USB sticks should be formatted to FAT32. The path is always the same. Thank you for your comment.
@elianousdu30
@elianousdu30 15 күн бұрын
@@SYPHOANG Thank you very much !
@sakurag55
@sakurag55 26 күн бұрын
Hi.. I successfully ping the device but rslinx cannot found the device.. rslinx also not browsing at all. Want to know why and how to solve it. Thank you
@SYPHOANG
@SYPHOANG 25 күн бұрын
@sakurag55: Thank you for subscribing to my channel. Is your device from Allen Bradley? Sometimes you might have to remove the driver and re-configure it again. If you want to do it automatically, you should select "Ethernet/IP driver" under "Available driver types". After clicking "add new", make sure you select the driver that has your computer IP address on the same network with the device that you want to see in "Rslinx". Hopefully this helps.
@RohitSormasf
@RohitSormasf 27 күн бұрын
Smith David Martin Lisa Rodriguez Deborah
@SYPHOANG
@SYPHOANG 23 күн бұрын
@RohitSormasf:???
@dewalaknat8732
@dewalaknat8732 29 күн бұрын
HMI iidec emergency error appears Please help 🙏
@SYPHOANG
@SYPHOANG 27 күн бұрын
@dewalaknat8732: what message you got on the HMI? what is the error code?
@abrarahmednabil1283
@abrarahmednabil1283 Ай бұрын
nice
@SYPHOANG
@SYPHOANG Ай бұрын
@abrarahmednabil1283: Thanks for your support to my channel.
@zainshafiq1923
@zainshafiq1923 Ай бұрын
Can you explain why only port 1 of MB3280 will work in this case? Is it possible to read modbus data from both ports simultaneously.
@SYPHOANG
@SYPHOANG Ай бұрын
@zainshafiq1923: I have not tried the other port but I believe it's very possible. you can use it as a different serial communication interface to talk to the same slave/server device. If I have some free time, I willing definitely test it out for you.
@dychristerchrister6477
@dychristerchrister6477 Ай бұрын
Hello.how too link.Compactlogic Allen Bradley PLC to hmi panelveiw 800?
@SYPHOANG
@SYPHOANG Ай бұрын
@dychristerchrister6477: You might want to check out the video below. If it’s helpful, please do not forget a “super thanks” to show your support to my channel. kzbin.info/www/bejne/r6TFfHinhbeSh6ssi=hItfJvWy4U3ptOfO
@abrarahmednabil1283
@abrarahmednabil1283 Ай бұрын
help full.
@SYPHOANG
@SYPHOANG Ай бұрын
@abrarahmednabil1283: ???
@AbdullahAhmed-vj2vi
@AbdullahAhmed-vj2vi Ай бұрын
❤❤❤
@SYPHOANG
@SYPHOANG Ай бұрын
@AbdullahAhmed-vj2vi: Thank you for your support to my channel.
@AbdullahAhmed-vj2vi
@AbdullahAhmed-vj2vi Ай бұрын
@@SYPHOANG you deserve more than like 👍..
@SYPHOANG
@SYPHOANG Ай бұрын
@AbdullahAhmed-vj2vi: Thank you for your kind words. If you want and you feel comfortable, you can give me a "super thanks" at the lower left corner. Thank you :)
@maicolherrera7685
@maicolherrera7685 Ай бұрын
Una ayuda, es que el plc el led dcom se mantiene encendido, pero el chanel 0 esta configurado diferente, que puedo hacer para que el dcom se apague y se reestablezca la comunicación, se mantienen las salidas encendidas pero no hay funcionamiento de las entradas digitales
@SYPHOANG
@SYPHOANG Ай бұрын
@maicolherrera7685: "DCOM" means DEFAULT COM. Default Com is DF1. Once you change the Communication Protocol to anything but DF1, the DF1 light will be turned OFF. But what should be the communication protocol for the channel is the question for you. You can look into the other device that your PLC is connected to and find out what communication protocol and configuration it is looking for from your PLC. Hope that helps. Good luck
@maicolherrera7685
@maicolherrera7685 Ай бұрын
@@SYPHOANG cuando hago la descarga con la modificación del Chanel 0, el PLC me impide conectarme otra vez y por eso no me deja ponerle run
@SYPHOANG
@SYPHOANG Ай бұрын
@maicolherrera7685: It's very simple. You pressed the button on the PLC to set the default DF1 to Channel 0, the DCOM turned ON. However channel 0 in the program you downloaded to the PLC is configured for DH485 or anything but DF1. My guess is DCOM light turned OFF after you downloaded the program to the PLC because channel 0 is now no longer set for the default DF1. You can no longer connect to the PLC because of the cable between your PLC and your computer. My guess is the cable you use is for DF1 communication protocol, it is not for the communication protocol for channel 0 in the program you downloaded to the PLC. I think that was also the reason you set the default DF1 to channel 0 on the PLC. If I was you, I would never reset channel 0 on the PLC back to DF1. My recommendation is to always find the right cable that works for the communication protocol configure in the PLC program before any downloads. Please consider joining my channel for more support. kzbin.info/door/yyYzqg0sp_W7CW9ScZh-zAjoin
@vleiswalker9374
@vleiswalker9374 Ай бұрын
This worked! Thank you very much!
@SYPHOANG
@SYPHOANG Ай бұрын
@vleiswalker9374: Glad it was helpful.
@AuxiliarMantenimientoSPICOL
@AuxiliarMantenimientoSPICOL Ай бұрын
una pregunta si yo presione el boton com del plc, y se cambio al chanel 0 que puedo para reestablecer el canal que tenia con el scaada al que le esta enviando los datos
@SYPHOANG
@SYPHOANG Ай бұрын
@user-fb9rd2dl4l: Unfortunately I don't think that would be possible. However you can look into your scada system to find out what communication protocol and configuration it is looking for from the micrologix1200 PLC. Then you can set it up again in the PLC logic. Good luck.
@AuxiliarMantenimientoSPICOL
@AuxiliarMantenimientoSPICOL Ай бұрын
@@SYPHOANG muchas gracias, asi lo hare es que eso es lo curioso cuando por defecto la comunicacion al presionar el boton com, se visualizan unos datos en el scada, y al apagar el plc, se dejan de ver esos datos
@khachapatrachatamethin7484
@khachapatrachatamethin7484 Ай бұрын
I cannot reach out your documents in dropbox.
@SYPHOANG
@SYPHOANG Ай бұрын
@khachapatrachatamethin7484: which document in my dropbox are you trying to download? The full links might be available for channel members only.
@SYPHOANG
@SYPHOANG Ай бұрын
@khachapatrachatamethin7484: Are you Samroeng Kanathong who is trying to download the function block "Lead_Lag_STBY_BLK.7z"? If you can confirm it is you and that is what you need, I can share you this file only as an exception for a potential channel member. All function blocks are for channel members only. Please consider joining my channel for more support. kzbin.info/door/yyYzqg0sp_W7CW9ScZh-zAjoin
@khachapatrachatamethin7484
@khachapatrachatamethin7484 Ай бұрын
@@SYPHOANG thank you so much. I can reach out to your document right now. I wonder how to convert XML file back to Excel file. Could you please help?
@SYPHOANG
@SYPHOANG Ай бұрын
@khachapatrachatamethin7484: Are you trying to download the function block "Lead _Lag_STBY_BLK.7z" and import it into your PLC project in Connected Components Workbench? If so, you need to download and import the file with ".7z" extension into your PLC project. No need to worry about other files.
@khachapatrachatamethin7484
@khachapatrachatamethin7484 Ай бұрын
@@SYPHOANG nope.
@punishedgoy9131
@punishedgoy9131 Ай бұрын
Great video !
@SYPHOANG
@SYPHOANG Ай бұрын
@punishedgoy9131: Thank you for your support to my channel.
@yijunhuang1005
@yijunhuang1005 Ай бұрын
謝謝!
@yijunhuang1005
@yijunhuang1005 Ай бұрын
If we check the Expanded box at 1:06, how much can it expand? Isn't the maximum length of N File only 255?
@SYPHOANG
@SYPHOANG Ай бұрын
@yijunhuang1005: Thank you for your support to my channel. Yes, it might be 255 max.
@yijunhuang1005
@yijunhuang1005 Ай бұрын
Good Video, Very Helpful~
@SYPHOANG
@SYPHOANG Ай бұрын
@yijunhuang1005: Glad it was helpful!
@T---dq2qv
@T---dq2qv Ай бұрын
Oh when i restored it and edit a lots , then How I can change it to an.mer file to download to the hmi
@SYPHOANG
@SYPHOANG Ай бұрын
@T---dq2qv: In the "FactoryTalk View Studio", at the very top, select " Application", then click on "Create Runtime Application". Be careful to pick up the right version for the .mer file you want to create at " Save as type"? Make sure its version is lower than your HMI firmware. Good luck.
@Man_Arm92
@Man_Arm92 Ай бұрын
Its works, Thanks
@SYPHOANG
@SYPHOANG Ай бұрын
@Man_Arm92: You're welcome!
@simonngo7085
@simonngo7085 Ай бұрын
can you used this hmi with allen bradley
@SYPHOANG
@SYPHOANG Ай бұрын
@simonngo7085: Thank you for subscribing to my channel. I have not tried it with any Allen Bradley PLC but I think it is very possible.
@punishedgoy9131
@punishedgoy9131 Ай бұрын
Great video
@SYPHOANG
@SYPHOANG Ай бұрын
@punishedgoy9131: Glad you found it useful. Thank you for your support to my channel.
@punishedgoy9131
@punishedgoy9131 Ай бұрын
What’s the model of your gateway?
@SYPHOANG
@SYPHOANG Ай бұрын
@punishedgoy9131: It is Secomea SiteManager 1549.
@punishedgoy9131
@punishedgoy9131 Ай бұрын
@@SYPHOANG please please please make a video on the site master
@SYPHOANG
@SYPHOANG Ай бұрын
@punishedgoy9131: Thank you for your interest in the Secomea SiteManager 1549. Below video is what you might want to check out. kzbin.info/www/bejne/d6bcZpVqZbF7nbssi=0uyJTLIuTSko2mhf
@T---dq2qv
@T---dq2qv 2 ай бұрын
oh i have a question, the version of sorfware is 20.00.00 you update the version of firmware is 20.019 sso the version of firmware is higher than, is it ok ?
@SYPHOANG
@SYPHOANG 2 ай бұрын
@T---dq2qv: firmware and software version are different. They are not exactly the same. The software is what is installed on your computer while firmware is what is installed on the controller. The key point is firmware version ALWAYS need to be higher than the software one. Hopefully that clearly answers your question.
@T---dq2qv
@T---dq2qv Ай бұрын
@@SYPHOANG thanks you very much for this anwser , so the firmware version alway need higher than sorfware one , such as Firmware version is 20.019 and firmware version do not higher than 20 such as 21.00.00 is it right
@SYPHOANG
@SYPHOANG Ай бұрын
@@T---dq2qv Correct.
@InstrumentacionExterran
@InstrumentacionExterran 2 ай бұрын
Esto se podria simular en el RSLOGIX EMULATE?
@SYPHOANG
@SYPHOANG 2 ай бұрын
@InstrumentacionExterran: No, this is "Connected Components Workbench" software.
@InstrumentacionExterran
@InstrumentacionExterran 2 ай бұрын
Podrias compartir, el archivo ACD, gracias
@SYPHOANG
@SYPHOANG 2 ай бұрын
@InstrumentacionExterran: ACD files are for Studio5000/ControlLogix or CompactLogix PLC's. This is Micro800's PLC that uses Connected Components Workbench for programming.
@YohDave
@YohDave 2 ай бұрын
How can I get a string data? Like a serial number or something like that?
@SYPHOANG
@SYPHOANG 2 ай бұрын
@YohDave: You can use "STRING" data type and get up to 82 characters for each tag.
@YohDave
@YohDave 2 ай бұрын
@@SYPHOANG Thanks! Do you know how can I write the serial number in the tag? Or how can I link the tag with to the serial number?
@SYPHOANG
@SYPHOANG 2 ай бұрын
@@YohDave From programming perspective, you create a "string" data type tag in the PLC program and then map it to the HMI for a manual data entry. I am not sure what you meant for "serial number"? Are you trying to connect your PLC to a barcode/QR code reader/scanner? If so, I am not familiar with these devices.
@YohDave
@YohDave 2 ай бұрын
@@SYPHOANG Thanks!
@karthikvhiremath1886
@karthikvhiremath1886 2 ай бұрын
Hello Sir, I want to read REAL valve from Power Meter through Modbus TCP communication... In AB Micro 850 PLC... Please suggest me best method...
@SYPHOANG
@SYPHOANG 2 ай бұрын
@karthikvhiremath1886: This is the right video for you. But do you have all the information you need for data mapping? You need to know the IP address, subnet mask, the configuration of the power meter as well as its Modbus data mapping.
@karthikvhiremath1886
@karthikvhiremath1886 2 ай бұрын
@@SYPHOANG Thank you sir... I got one fbd from your video for 2 WORD TO REAL converter FBD absolutely working ultimately... So I need one more Instruction REAL to 2 WORD CONVERTER... If you have please give me link....
@CongDucDinh-s6c
@CongDucDinh-s6c 2 ай бұрын
Chào A. Video của a rất hay. mình thấy a có phần mềm FT-View anh có thể cho mình xin phần mềm để hổ trợ trong công việc nhé. Cảm ơn A.
@SYPHOANG
@SYPHOANG 2 ай бұрын
@CongDucDinh-s6c: Bạn có thể tải xuống từ Rockwell Automation.com. Nó sẽ cho bạn thời gian gia hạn là 7 ngày để dùng thử. Sau 7 ngày, bạn sẽ phải mua giấy phép từ nhà phân phối ủy quyền của Rockwell tại địa phương. Đó là cách tôi có được phần mềm tại nơi làm việc.
@joaopaulopaul
@joaopaulopaul 2 ай бұрын
Conseguiu me vender o soft. Dessa IHM
@SYPHOANG
@SYPHOANG 2 ай бұрын
@joaopaulopaul: ? Who is he?
@joaopaulopaul
@joaopaulopaul 2 ай бұрын
​@@SYPHOANG precisando do software do GP 2301 proface
@hchangv
@hchangv 2 ай бұрын
Excellent information, thanks for the contribution, I would like to know when you enter the password, is it a standard Rockwell one? or you enter a password for the first time to log in.
@SYPHOANG
@SYPHOANG 2 ай бұрын
@hchangv: The password I entered at 2:15 was set up earlier (not in this video). When you first power up a brand new HMI out of the box condition, it will prompt you to create it. There is no such default password coming from Allen Bradley. If you lost the password or simply do not know it, flashing the HMI firmware might wipe out everything including the password to allow you to set it up again. Thank you for your comments.