0035 Powerline Hardware Fuse Cutout- How to Load Polymer Cutout Fuse Barrel

  Рет қаралды 7,060

Utility Service Agency

Utility Service Agency

Күн бұрын

Пікірлер: 6
@diamondmwelwa4280
@diamondmwelwa4280 6 ай бұрын
Thank you for the clear demonstration❤
@aloiziocarlosEble
@aloiziocarlosEble 3 жыл бұрын
Hi! Could you let me know if it often happens that the fuse holder remains stuck (locked) after the link breaks?
@ElectroTree01
@ElectroTree01 Жыл бұрын
The tail would usually drop out of the door and hopefully not draw an arc. Sometimes it might stay in there which would be bad. It might melt through the side of the door after enough time.
@aubreyroche5080
@aubreyroche5080 2 жыл бұрын
Question, would you connect a new wire to the bottom of a 15kv fuse cut out with just the Cut out open, power still on main over head lines ? Trusting the Cut out insulator ?
@ElectroTree01
@ElectroTree01 Жыл бұрын
Sorry for late reply but you probably will disconnect the lead on the top of the cutout first although there is one crew who installed the top lead first. This is done with the cutout open. The main line is usually energized. And yes I guess you trust the cut out to insulate
@aloiziocarlosEble
@aloiziocarlosEble 3 жыл бұрын
Hi! Could you let me know if it often happens that the fuse holder remains stuck (locked) after the link breaks?
Powerline Hardware Polymer Fuse Cutout Overview
3:13
Utility Service Agency
Рет қаралды 30 М.
What's a bayonet fuse !?
7:01
Bobsdecline - Lineman blogger
Рет қаралды 20 М.
Try Not To Laugh 😅 the Best of BoxtoxTv 👌
00:18
boxtoxtv
Рет қаралды 6 МЛН
Сюрприз для Златы на день рождения
00:10
Victoria Portfolio
Рет қаралды 2,7 МЛН
How to whistle ?? 😱😱
00:31
Tibo InShape
Рет қаралды 22 МЛН
Я сделала самое маленькое в мире мороженое!
00:43
Lineman Tip #6 - Fusing cutouts
7:31
Bobsdecline - Lineman blogger
Рет қаралды 35 М.
Cutout Fuses, Red Links, Distribution and Building Network Operators
10:40
John Ward (jwflame)
Рет қаралды 38 М.
Eaton's Cooper Power series cutouts
3:50
Eaton
Рет қаралды 2,7 М.
Hazards, Best Practices, and How to Change Cutouts Safely
17:32
MP Systems Safety
Рет қаралды 12 М.
Changing a Power Line Fuse
2:38
emctv
Рет қаралды 110 М.
COMMUNISM vs CAPITALISM: Who Made Better Power Tools?
24:39
The Doubtful Technician
Рет қаралды 802 М.
Insulator Change Out On H-Structure At NLC
15:26
Marcus L
Рет қаралды 24 М.
Fuse blows back on lineman
1:15
deltabloo
Рет қаралды 4,5 МЛН
ELF Current Limiting Dropout Fuse
4:25
Eaton
Рет қаралды 4,1 М.
Try Not To Laugh 😅 the Best of BoxtoxTv 👌
00:18
boxtoxtv
Рет қаралды 6 МЛН