Very useful video. It provides lots of knowledge to understand the basic concepts of design the RO system.
@TheSmaul5Ай бұрын
Thanks This is a good lecture to help nonspacilists to follow the projects
@chandanthakur887312 күн бұрын
Thanks for the knowledge, please make a video on Software
@moayadqbilawi5102 жыл бұрын
Thank you for sharing,very informative video
@muhammadhassansaleem13992 ай бұрын
Impressive
@davidchunke8746 Жыл бұрын
thank you very much.
@olusojimartins8765 Жыл бұрын
Thank you David, it's quite explanatory.
@anleytadie9982 Жыл бұрын
So much thanks
@ekvinaysayaraj6071 Жыл бұрын
Thank David. I hope we could collaborate
@SHOHOB2000 Жыл бұрын
thanks for good explanation sir :-) but the equations sometimes are incorrect for example here 10:20 it should be 1-(Cp/Cf) also calculating salt rejection I got 0.957 not 0.97 and the big problem that made me write the comment is here 10:55 this equation will always give recovery=0 if salt rejection is calculated 0.957 then recovery will be zero its either salt rejection equation is false or recovery equation is false the explanation is very good but there are some mild mistakes that frustrated me until I checked the values that you calculated and saw the contradiction between the equations
@ChunkeWaterTreatment Жыл бұрын
You are right, typing mistake. It is 1-(Cp/Cf). Thanks for your kind attention....