You really made me understand now how to properly use the SFC14 and 15! You are one of the best YT teacher! I just have one question: 1) Where did you get those parameters in DBW 2.0, 4.0 and 6.0? Because I did not find it in the ABB Manual but you are getting a live data. Thank you!
@averageengineer42663 жыл бұрын
Thank you so much.., this vid is actually a continuation from my another video - kzbin.info/www/bejne/j2PTp5yqg559ma8 You will find the answer to your questions.
@sureshkandekar4140 Жыл бұрын
Thank Sir, for this detailed video, well explained.
@amernassor32452 жыл бұрын
very clear and simple to understand
@shahzadengr35683 жыл бұрын
Very Imformative video , Thanks alot
@ankitkumarmistry83103 жыл бұрын
and one more question is how we can choose DB values..means you select 1st 15 to 16 db values and their names..Is this same as manual parameters requirement or something else?
@averageengineer42663 жыл бұрын
If you are asking about DC bus voltage, motor current,etc.., this should be same as how you configure on your drive. First 2 words should always be command word and speed reference. Rest is upto your requirements
@mohamedeljabri497010 ай бұрын
Thanks a lot , I see some protected by lock , how do you open them ?
@carim62423 жыл бұрын
Thank you Please how display motor_current ? In DB
@averageengineer42663 жыл бұрын
Hi, DB1.DBW6 is assigned for motor current as per the program in the video.
@carim62423 жыл бұрын
I try to do like this put I think the problem from telegram always show example: 33Hz 0 Ampers !!!! Ampers no change
@carim62423 жыл бұрын
@@averageengineer4266 Micromaster always sending 0 Amper to PLC !
@averageengineer42663 жыл бұрын
@@carim6242 yes, you need to configure in telegram, iam planning to do a vid soon about sinamics drive to s7 400 commisioning. Betw you can check this vid - kzbin.info/www/bejne/r4XPdI2OeLGhm7c i have explained telegram setting on drive if it helps .
@kgauravb3 жыл бұрын
Excellent video, pls make video on Sinamics and ABB ACS drive using modbus control.
@amit38012 жыл бұрын
Really very useful....
@rooman12 жыл бұрын
Great tutorial
@rajeshsingh-eq3eg Жыл бұрын
Great video, by you. Kindly make some video how can we make our own sfc like sfc 14, 15, 20 .??
@tehseenarshad86022 жыл бұрын
Thamks v. Good video sir
@hamzajmili922 жыл бұрын
Thank you for this detailed video, well explained. Just I have one question : To communicate with G120 , why did you just duplicate the DB1 to DB2 ? How you know the ABB VFD and G120 have the same order of structure ( how could we know for example that the db1 dbx 13.0 ( OFF start for ABB brand ) is another thing parameter for example drive-Spec1 for siemens brand? Thank you in advance
@averageengineer42662 жыл бұрын
Thx for watching. Yes the control word is not exactly same ,but my point was to show the advantage of using db and sfc functions. If you are intrested in siemens control word ,pls see - kzbin.info/www/bejne/r4XPdI2OeLGhm7c. You can skip to 19.00
@avinashamberkar37802 жыл бұрын
I want to read energy consumption of G120 drive Parameters r0039 to s7-300 PLC. I set p039 in p2061 and check reading on PLC PIW 300 or pid 300 but it shows 32767 so please help me.
@averageengineer42662 жыл бұрын
It is easy, if you using scout, under profibus configuration, select transmit direction and link the free slot to the parameter you want to read. Same needs to be done in the plc side.
@ankitkumarmistry83103 жыл бұрын
I have one question.If I want to read actual motor speed in PLC what should I do for this?my plc is 300 series and s120 DP drive.please guide me.
@averageengineer42663 жыл бұрын
If you want to know the drive parameter setting - kzbin.info/www/bejne/r4XPdI2OeLGhm7c This video is sinamics g120 to abb plc configuration. But drive side will be same for any PLCs
@fawziamine30892 жыл бұрын
thank you very much I tried to download the ABB FC drive block to use in SIMATIC S7 to carry out the profibus communication between asc 880 and s7 drive but all the libraries who download me do not work and what you have an idea thank you in advance
@averageengineer42662 жыл бұрын
Thank you, if you are interested in a more detailed explanantion , pls see - kzbin.info/www/bejne/j2PTp5yqg559ma8
@alagarsamy3914 Жыл бұрын
Thanks brother
@nguoicoon58632 жыл бұрын
I connect S7 400 with ESEPRO profibus device. The process image is disable and no option. where did I do wrong?
@averageengineer42662 жыл бұрын
kzbin.info/www/bejne/j2PTp5yqg559ma8 - In this video, i have explained how to add profibus drive,hope it helps
@nguoicoon58632 жыл бұрын
@@averageengineer4266 Thank you. That was great support. I have one requirement please My factory has used s7 400 for 5 year. I connected to some profibus device Now, I need to connect addition profibus to s7 400. I installed new simatic manager software and read successfully program from S7 400. I wonder that, I have to import again gsd file of old profibus device or not? Please help me this topic. Thank.
@averageengineer42662 жыл бұрын
@@nguoicoon5863 Not required, it will be there in the program backup.
@nguoicoon58632 жыл бұрын
@@averageengineer4266 it mean that when I read program from PLC, the driver will update atomatically into my simatic manager software?
@최용갑-q6n3 жыл бұрын
이게 쉬운가요 저도 엄청 헷메죠 840D SIMOCOM611 나왔을때 혼자 고민 많이 했죠 그런데 벌써 단종이라니 이제야 알고 나니까. 기본이 안되면 절대 해결이 안되죠.
@rexcheng45673 жыл бұрын
I appreciate that very much! I have a question: Are these 2 SFCs only working for the profibus? For example, on the SFC14, do I just need to put the address value 'W#16#xxx' to the 'LADDR' without the sign 'PIW' or sth tag ahead the 'W#16#xxx'?
@averageengineer42663 жыл бұрын
SFC14 can be used to read any PIW values, Just convert the starting PIW address to HEX value for LADDR and enter the correct number of Bytes as shown in the video.
@rexcheng45673 жыл бұрын
@@averageengineer4266 I have a question for the 'LADDR' as below L #DP_start_address // INPUT interface of FC , this FC is called by another FB ,and this pointer is put with the address '508' ; T MW200 CALL "DPRD_DAT" SFC14 LADDR= MW200 // I'm confused by this transfer. Is the INT input '508' also valid? In general , it should be switched to Hex RET_VAL= MW600 RECORD= P#DP
@averageengineer42663 жыл бұрын
@@rexcheng4567 Yes, this way also works. When you load 508 to mw200, hex value of 508 is there in mw200. When you are online in the program, change the representation to hexadecimal and you can find hex value of 508 in mw200
@rexcheng45673 жыл бұрын
@@averageengineer4266 Why do we have to take the byte swap with the ABB? By this question, if we read the value like the DC bus by word, why don't we have to switch the 2 bytes?
@averageengineer42663 жыл бұрын
@@rexcheng4567 to be honest, even i was confused why there is a byte swap. When i interfaced acs 880 to a ABB plc, there is no byte swap, you can find that vid in my channel. I think it has something to do with memory architecture of the siemens plc, i found tge same byte swap when i interfaced sinamics drive to s7 400
@anveshjadav2 жыл бұрын
I didn't get why you multiplied ref to 200 ? and while reading divide it by 20?
@averageengineer42662 жыл бұрын
200 is the scaling factor for the speed in percentage. While reading also you need to divide by 200, if i said 20 in the video, it might have been a mistake, thanks
@averageengineer42662 жыл бұрын
kzbin.info/www/bejne/j2PTp5yqg559ma8 - better explained vid
@thippesh_trpani6584Ай бұрын
Thank u so much
@sinanartemis6176Ай бұрын
sir i have an s7 315 pn dp cpu, i connected a cp343-1 cp card to the plc and i want to make an profinet bus and via that profinet bus i want to drive a abb acs580 vfd. when i completed the hardware configuration i saw a pop up opened and it says if you want to use cp you should use fc12 and fc11 profinet send receive io block's can you help me i couldn't find the solution yet. have a nice day
@balDer-ms2roАй бұрын
its really hard to learn PLC program. you must do it daily and years to master it