Door Locations 15-0

  Рет қаралды 14,056

Marty Huie

Marty Huie

Күн бұрын

This video is on where doors you be located in a room where the occupied requires more than one door. Most occupancies that threshold is 49 people. Once that threshold is met two doors are required and a shout be remotely located from each other. Storage occupancies the threshold is 29, institutional occupancies most are around 10, hazard three people require you to have more than one door but with hazard on doors shall swing in the direction of travel.These videos are to understand building code

Пікірлер: 13
@tristansacousticcover8388
@tristansacousticcover8388 4 жыл бұрын
Explained well..you enlightened Me to our Code here in the Philippines, The R.A. 9514 Fire Code of the Philippines..thank you so much SIR!👍👍
@microphonehead55
@microphonehead55 7 жыл бұрын
These videos are so great! thanks for making these!!!!! I'm going through all of them right now.
@MartyHuie
@MartyHuie 7 жыл бұрын
WOW Thank you so much
@ptarchitect3829
@ptarchitect3829 6 ай бұрын
Which code you're taking notice from
@MartyHuie
@MartyHuie 6 ай бұрын
Both IBC and NFPA virtually have the same requirements so that's why I did not quote what section and what code. Chapter 10 of IBC and chapter 7 of NFPA these requirements that I speak up here have been in place since virtually kingdom come
@papajingtv
@papajingtv 5 жыл бұрын
Great video.. tnx
@irvine14
@irvine14 10 жыл бұрын
excellent video, although it should be "1/2 * D = x", not 1/2 ÷ D = x" !!
@MartyHuie
@MartyHuie 10 жыл бұрын
Thank You so Much you are correct, I will fix it soon. I posted on my side that I was wrong and it was brought to my attention. Thank YOU for the check. Please let me know if you find anything else.
@mattnoblitt6260
@mattnoblitt6260 10 жыл бұрын
If the occupancy load of an "A" space that is sprinkled is 600 it requires 3 exits, and 1 of those must be 1/2 (I have not found 1/3)the diagonal distance from one of the others. My question is what is the minimum distance between the third door and either of the others? Thanks again for the clarification.
@MartyHuie
@MartyHuie 10 жыл бұрын
Matt Noblitt Matt, Great question, I have always applied each door independently of each other so that all doors in a fully sprinkled building where one 3rd by diagonal distance from each other. That is not saying that is the code. I'll be traveling today so I will have time on the plane to do some reading hopefully the next day or so I should be able to give you at least my opinion of what the code reference reads.
@10E-g2w
@10E-g2w 3 жыл бұрын
Your math is wrong. You multiply the diagonal by 1/2 or 1/3.
@MartyHuie
@MartyHuie 3 жыл бұрын
you are correct my words are wrong, The MATH :) is correct. I say divide when I should say multiply you are correct.
@MartyHuie
@MartyHuie 12 жыл бұрын
Door Location's
Fire Extinguisher Locations 14-0
2:49
Marty Huie
Рет қаралды 28 М.
Door & Stair Width 7-0
7:26
Marty Huie
Рет қаралды 47 М.
coco在求救? #小丑 #天使 #shorts
00:29
好人小丑
Рет қаралды 120 МЛН
СИНИЙ ИНЕЙ УЖЕ ВЫШЕЛ!❄️
01:01
DO$HIK
Рет қаралды 3,3 МЛН
AC 021 - Stair ADA and IBC requirements
17:25
archicorner
Рет қаралды 38 М.
AC 028 - What are Dead End Corridors and how to avoid them?
6:49
Dead End 13-0
4:42
Marty Huie
Рет қаралды 21 М.
Smoke Compartments what are they 31-0
5:43
Marty Huie
Рет қаралды 11 М.
MASTER Building Code Analysis in 10 EASY Steps
17:52
ArchitectPrepCourse
Рет қаралды 1,5 М.
Door Encroachment 18-0
4:24
Marty Huie
Рет қаралды 16 М.
AC 049 - Corridors Vs. Exit Passageways (with corrected audio)
5:30