@robinbrowne5419
@robinbrowne5419 Жыл бұрын
It's always fun to see analog and RF electronics. It brings back memories of college. For dB's our electronics teacher told us to remember 4 things and we could figure out everything from there. 0dBm = 1mW -3dB = x0.5 0dB = x1 3dB = x2 But I still feel like the sorcerer's apprentice trying to cast the incantations :-)
@IMSAIGuy
@IMSAIGuy Жыл бұрын
those are good things to remember
@Randrew
@Randrew Жыл бұрын
For dB-anything it may be more important to remember that 0 dB is the reference level for "anythings". dBm is decibels "milliwatt" so 0 dBm is the reference level of 1 milliwatt. Another common one is dBA for audio noise level, where 0 dBA is the threshold of human hearing. For any measure, decibels do apply the same as your other rules: every 3 dB up is a doubling, 3 dB down is a halving. This *should* be really important for car audio enthusiasts who might think 133 dBA is "only" 3 more than 130 dBA. Yeah, bro... it's "only" twice as loud ;)
@robinbrowne5419
@robinbrowne5419 Жыл бұрын
@@Randrew Yes. It does seem weird that going up by 3db makes twice as much. But that's how the math works. It took me a while to get used to that.
@IMSAIGuy
@IMSAIGuy Жыл бұрын
6db volts 3dB watts
@Randrew
@Randrew Жыл бұрын
@@IMSAIGuy = -3 dB Amperes?
@enojelly9452
@enojelly9452 Жыл бұрын
When measuring the 60dB pad, maybe check under "Amplitude" whether the attenuator of the analyzer itself is enabled. On my Rigol, it usually is by default, unless I set the reference level to something like -50dB or so. If your SA has a preamplifier, then of course enabling that helps as well (and on mine at least also disables the attenuator, wouldn't make much sense otherwise), but that's only if it has it.
@tomsherwood4650
@tomsherwood4650 Жыл бұрын
For RF power meters, if you don't have a wide variety of expensive sensors, you want alot of different attenuators to stay under the max power allowed. So measuring your attens is nice because if you got a 20 db pad and it is 20.1 or .2 at your freq, you often have to stack them and the errors accumulate. OF course HP power meters often have a reference source but it is fixed freq.
@IMSAIGuy
@IMSAIGuy Жыл бұрын
correct kzbin.info/www/bejne/rWTcd6aHlMeUnLM
@bobdoritique7347
@bobdoritique7347 Жыл бұрын
Merci for this video.
@BaldurNorddahl
@BaldurNorddahl Жыл бұрын
My SSA3032X-R includes VNA so you can do this two different ways. I prefer the VNA method as I am more used to that.
@YO6TJJ
@YO6TJJ 7 ай бұрын
@IMSAI Guy can you please share what kind of coaxial cables are you using for your spectrum analyzer test setup and measurements? What kind of quality coaxial cables to you recommend for SA measurements in D.C. to 3.5GHz range for example? I just purchased the SSA 3021X and looking forward to acquire high quality coaxial for measurements. Thank you in advance! 73 de Andrei, YO6TJJ
@IMSAIGuy
@IMSAIGuy 7 ай бұрын
That is difficult as good cables can cost as much as the SA. I would not worry much at 3.5GHz. I have used cables made by GORE and Pasternack and Huber+Suhner. these new would be in the $300 to $1000 range. and used I got them for 1/10th the price. kzbin.info/www/bejne/mXfbZHeqjZ14l9Esi=wt46HLID0PyfgV_9
@ac4nl
@ac4nl Жыл бұрын
Greetings... Noticed the delta of the attenuator at the higher frequency sweep even with devices specd for very high frequency. Curious, have you ever used, like store trace at the noise floor etc, with and without tracking generator on / off and see how much, if any leakage occurs between the input and ouput ports ? It's possible that phase leakage could be causing the slight deviation of the attenation measurement.. thanks
@IMSAIGuy
@IMSAIGuy Жыл бұрын
this is not the best way to measure. yes there will be other factors that try to be calibrated out. the best would be a true open short load cal. but even a good VNA will not be as accurate as a good scalar network analyzer setup. the best is fixed frequency and a power meter
@paulcohen1555
@paulcohen1555 Жыл бұрын
The wiggly waveform of the attenuators on the Siglent spectrum analyzer appeared all the same. Is it possible that it was caused by the instrument itself?
@IMSAIGuy
@IMSAIGuy Жыл бұрын
yes
@tiftik
@tiftik Жыл бұрын
Is it possible to normalize the TG output, like a VNA would?
@IMSAIGuy
@IMSAIGuy Жыл бұрын
@@tiftik yes, I do that at 1:30
@tiftik
@tiftik Жыл бұрын
@@IMSAIGuy I wonder what causes the wiggles then... Perhaps a minuscule impedance mismatch somewhere.
@davidv1289
@davidv1289 Жыл бұрын
@@tiftik Most likely it is the test cable used to connect the attenuator to the spectrum analyzer.
@modulo-engineering
@modulo-engineering Жыл бұрын
awesome video, thx,
@georgelioulios1634
@georgelioulios1634 Жыл бұрын
Hello imsai, the 3015x plus (max 1.5ghz) do you know if use same hardware with 3021x?
@IMSAIGuy
@IMSAIGuy Жыл бұрын
I don't know
@Randrew
@Randrew Жыл бұрын
It is not the same hardware. The 3021 and 3032 *are* the same hardware as each other, but the 3015 is not so it cannot be modified to go to a higher max frequency like the 3021 can.
@jspencerg
@jspencerg Жыл бұрын
When would a SA with TG be needed rather than using a VNA?
@IMSAIGuy
@IMSAIGuy Жыл бұрын
the SA is a much cheaper device so most labs did not have a vna (pre nanovna). the SA is also more rugged and maybe better suited for measuring things like amplifiers.
@jspencerg
@jspencerg Жыл бұрын
@@IMSAIGuy Oh yes, your communications analyzer comes to mind for wattage capability. Perhaps you could dissect and analyze some faulty attenuators. I'm always curious about the $$$ divide between the components we can get.
@jeremycyclist6269
@jeremycyclist6269 Жыл бұрын
@@jspencerg Newer model, the SSA3021X Plus spectrum analyzer can be easily hacked to SVA1032 (SA + VNA), more information can be found on the EEVblog forum. The SSA3021X Plus in only $255 more expensive than the SSA3021X.
@Randrew
@Randrew Жыл бұрын
@@jeremycyclist6269 The SSA3015 can use the same hack to become an SVA1015. I've done the first step, opening up the software features, but haven't had the courage to swap to the SVA firmware. Also one of IMSAI Guy's recent videos, this one or the previous SSA one, mentioned the SVA having an RF bridge built in... I don't recall seeing that difference mentioned in the EEVblog forums. Kind of important since that means a piece of hardware is missing in one's "hacked" SSA -> SVA
@IMSAIGuy
@IMSAIGuy Жыл бұрын
the signal path and dave both did detailed teardown videos of the PCB
@MrDonTabasco
@MrDonTabasco Жыл бұрын
You don't have to store to ref when you normalize the TG, it does that automatically.
@IMSAIGuy
@IMSAIGuy Жыл бұрын
I've seen some that act that way, but not this model, you have press two keys
@MrDonTabasco
@MrDonTabasco Жыл бұрын
@@IMSAIGuy I've got the exact same model (original bandwidth though) and it does it automatically.
@IMSAIGuy
@IMSAIGuy Жыл бұрын
@@MrDonTabasco that's odd. have you updated the firmware to the latest?
@gwc1410
@gwc1410 Жыл бұрын
I have seen many spectrum analyzer videos talking about normalizing the tracking generator trace and using the "Store Ref" button. Some people say to press this button and others say don't press the button, even on the exact same spectrum analyzer. There seems to be a lot of confusion about this. I have a Rigol DSA815-TG Spectrum Analyzer.
@Randrew
@Randrew Жыл бұрын
OK, guys... chill out or you're gonna make me read the darned manual!
@gwc1410
@gwc1410 Жыл бұрын
You mention "attenuator" and "pad", and appear to talking about the same thing. This is very confusing. Can you explain this.
@Randrew
@Randrew Жыл бұрын
Old terms that ARE the same thing. Passive Attenuator Device = pad.
@IMSAIGuy
@IMSAIGuy Жыл бұрын
yup potato = spud
@tomsherwood4650
@tomsherwood4650 Жыл бұрын
A 6 dB "pad" is used on signal generators outputs when checking radio receivers that are supposed to be nominally 50 ohm inputs, I think it has to do with isolation and also maintaining an actual 50 ohms to the generator. Then you add subtract 6 from the reading.
@charlesmangum2100
@charlesmangum2100 Жыл бұрын
Bood referance information.
#1368 10W 30dB Attenuator
8:04
IMSAI Guy
Рет қаралды 9 М.
#545b TinySA Using Attenuators
14:43
IMSAI Guy
Рет қаралды 19 М.
Yay, My Dad Is a Vending Machine! 🛍️😆 #funny #prank #comedy
00:17
Osman Kalyoncu Sonu Üzücü Saddest Videos Dream Engine 275 #shorts
00:29
小蚂蚁会选到什么呢!#火影忍者 #佐助 #家庭
00:47
火影忍者一家
Рет қаралды 130 МЛН
🕊️Valera🕊️
00:34
DO$HIK
Рет қаралды 18 МЛН
Spectrum Analyzers Step by Step (029c)
28:15
Electronics for the Inquisitive Experimenter
Рет қаралды 27 М.
Let's Build an Octopus (IV Curve Tracer)
20:45
Gary LaRocco
Рет қаралды 4,3 М.
#1366 RF Bridge
12:07
IMSAI Guy
Рет қаралды 15 М.
Build this Spectrum Analyzer Protection Circuit
22:28
Mr Carlson's Lab
Рет қаралды 53 М.
HP 8561E Spectrum Analyzer Teardown, Repair, Modification, And Test
58:27
Erik's Electronics Workbench
Рет қаралды 6 М.
Attenuators Explained for Ham Radio Beginners
9:36
TheSmokinApe
Рет қаралды 10 М.
🔴 New Toy ! - Siglent SSA 3021X Plus Spectrum Analyser - No.1150
12:23
Defpom's Electronics Repair
Рет қаралды 6 М.
#581 Digital Programmable RF Attenuator
12:49
IMSAI Guy
Рет қаралды 12 М.
Yay, My Dad Is a Vending Machine! 🛍️😆 #funny #prank #comedy
00:17