16 - Sprinkler Systems - Introduction to Fire Alarms

  Рет қаралды 142,789

Joe Klochan

Joe Klochan

Күн бұрын

Пікірлер: 26
@TemiAbiel
@TemiAbiel Ай бұрын
This is the best content on fire protection out there by far. Thank you Joe.
@jcnash02
@jcnash02 4 ай бұрын
Joe, thanks for these videos, 11 years later. You should consider uploading them to Udemy or another platform like that to get a little income coming in from it.
@lukefh3093
@lukefh3093 4 жыл бұрын
dude these videos are absolutely amazing! I've already watched 16 straight in one sitting. Thanks for all this information, really helps understand the shit my journeymen don't have the time to explain on site
@JoeKlochan
@JoeKlochan 3 жыл бұрын
You must have a little time, considering you watched 16 in one sitting 🤣
@saidajanane2146
@saidajanane2146 Жыл бұрын
I WILL ABOSOLUTLY NAME YOU THE GRAND FATHER OF FIRE ALARM SYSTEM WOOOOOOW I NEED TO GET YOU A GIFT MAN
@ashleycordova2379
@ashleycordova2379 Күн бұрын
You been getting me to understand better joe !
@chuckmartin5254
@chuckmartin5254 7 жыл бұрын
I remember watching your videos a couple years ago and was reminded of them this weekend. They were a help then and now, too, and I definitely recommend for others getting into the work!
@DL-bx9wc
@DL-bx9wc 8 жыл бұрын
Need a video on elevator recall! These videos are great.
@kinkisharyocoasters
@kinkisharyocoasters 11 жыл бұрын
@Joe Klochan This YT "course" has been very educational, it's made me think of alarms in a different way. But what I don't get about sprinklers is that, what if there's an electrical fire? It's not like the heat would be less intense. Also, like trouble bells, I've noticed many buildings have waterflow bells by the panel and/or outdoors. I guess this tells people it's a real fire, because sprinklers do not activate during prank alarms or fire drills. But does the panel need to be addressable to make such a bell ring?
@JoeKlochan
@JoeKlochan 11 жыл бұрын
Sprinkler systems are not considered life safety devices for that reason. They are for property protection. In the case of electrical fires, smoke detectors would be needed to detect them. Trouble bells are different than sprinkler bells. Typically, sprinkler bells are not tied to the fire alarm panel at all. There are usually two independent sets of contacts on a waterflow switch. The sprinkler bells run on 120 VAC, and the hot leg of that circuit goes through the waterflow switch just like a light switch. When water flows, the contacts close and 120 VAC is passed to the bell, making it ring.
@kennethcarroll5420
@kennethcarroll5420 6 жыл бұрын
where can i learn, in a class room setting, how to install and wire in fire protection systems? thanks for the video
@ArabianStallion
@ArabianStallion 8 жыл бұрын
Thank you so much. I learned something new today
@Angrychefofficial
@Angrychefofficial 11 жыл бұрын
Where are videos 14 and 15? Thanks for all the info. Ive been in the bizz for quite a few years and this info is good!
@masterwireinc1313
@masterwireinc1313 5 жыл бұрын
Happy to be in same city with you!
@JoeKlochan
@JoeKlochan 12 жыл бұрын
Believe it or not, I use Microsoft Paint. I believe he uses a program called Smoothdraw. I tried smooth draw as well. It works better with the pen/tablet I use, but I can't copy and paste images as easily, and that's a big part of what I do. I use screen capture software called "Snagit". It's only $50.
@shariqanvar
@shariqanvar 11 жыл бұрын
great work...thank u very much
@SmartcadSoftwareSolutions
@SmartcadSoftwareSolutions 8 жыл бұрын
is shut off valve also called zone control valve?
@incubus_the_man
@incubus_the_man 12 жыл бұрын
I was wondering, what illustration software do you and Khan use to do these videos?
@kuldip2604
@kuldip2604 Жыл бұрын
Every time I run washing machine, the pressure in the fire sprinkler gauge increases. We thought the gauge might be faulty so we replaced but still the same. the pressure increases with every laundry. Based on your diagram, i don’t understand how is this possible?
@JoeKlochan
@JoeKlochan Жыл бұрын
Yeah that doesn't really make sense to me either, but I'm not a sprinkler expert.
@shariqanvar
@shariqanvar 11 жыл бұрын
joe!!!Where are videos 14 and 15?
@Angrychefofficial
@Angrychefofficial 11 жыл бұрын
Average bulb temp is 155Deg. Just fyi
@GauravChaudhary7307
@GauravChaudhary7307 8 жыл бұрын
so u just dont know what kinda element/liquid is used to fill those switches?!!..then what u are trying to make us understand in this 10min video??
@danielbledsoe2895
@danielbledsoe2895 8 жыл бұрын
Gaurav Chaudhary its water with colored dye
@GauravChaudhary7307
@GauravChaudhary7307 4 жыл бұрын
@Aslin Fire Safety bro that was 3 years ago chill xD
18 - Dry Sprinkler Systems - Introduction to Fire Alarms
13:04
Joe Klochan
Рет қаралды 124 М.
17 - Sprinkler Systems (con't) - Introduction to Fire Alarms
12:08
VIP ACCESS
00:47
Natan por Aí
Рет қаралды 19 МЛН
Интересно, какой он был в молодости
01:00
БЕЗУМНЫЙ СПОРТ
Рет қаралды 3,8 МЛН
Beat Ronaldo, Win $1,000,000
22:45
MrBeast
Рет қаралды 147 МЛН
Fire Sprinkler system | Firefighting lesson 6
13:56
AMJ Engineering
Рет қаралды 318 М.
15 - How Duct Detectors Work - Introduction to Fire Alarms
10:24
Joe Klochan
Рет қаралды 83 М.
How fire sprinkler systems work (3D Animation)
4:09
ScienceWorld
Рет қаралды 364 М.
19 - Dry Sprinkler Systems (con't) - Introduction to Fire Alarms
11:27
Service Tech Life #3: NAC troubleshooting
7:20
Service Tech Life
Рет қаралды 7 М.
Fire Sprinkler Types - Wet / Dry / PreAction
2:51
Silco Fire & Security
Рет қаралды 35 М.
5 Story Building Project - Sprinkler Room Part 1
13:22
Joe Klochan
Рет қаралды 11 М.
Full Movie "A Day In the Life of a Fire Sprinkler Technician"
15:04
Kord Fire Protection
Рет қаралды 13 М.
Fire Alarm Basics
36:24
IAFCTV
Рет қаралды 18 М.
VIP ACCESS
00:47
Natan por Aí
Рет қаралды 19 МЛН