2.5” Commercial Attack and Extend - Brass Tacks & Hard Facts (Episode 26)

  Рет қаралды 40,835

Elkhart Brass

Elkhart Brass

7 жыл бұрын

The Art of the Engine continues as Jeff Shupe shows the methodology of using a 2.5” in a simulated commercial attack into an overhead door, and then using a hose bundle to extend with a more manageable line for final extinguishment. Jeff talks big water attack, line management, and crew teamwork and how they all contribute to the success of an operation like this.
Browse more engine company ops videos, request training or demos and more at www.brasstackshardfacts.com

Пікірлер: 8
@ronaldrobertson2332
@ronaldrobertson2332 4 жыл бұрын
NOW I see all this neat stuff long after I've gotten too old and decrepit to put it to use! Oh well, maybe it's time to pick up my pen and pencil and draw about it again, using this and my own experiences as a guide. Thanks guys! You're reinvigorating my soul again! I loved being a volunteer firefighter (1979-2004)!
@megaweld7018
@megaweld7018 3 жыл бұрын
Good Stuff ! The Art of using the 2.5 Handline is a Lost Art that needs to be restored to the Fire Service of today !
@nickp76
@nickp76 5 жыл бұрын
Does the pump operator need to increase pressure to account for the additional 1.75" attack line being added to the system?
@randyayo2846
@randyayo2846 5 жыл бұрын
Looks like they only added a 50 foot length, that won’t change things much.
@srwinchell
@srwinchell 4 жыл бұрын
Depends a ton on the lengths and flows of each line. You are reducing volume, so there will be a lot less friction loss in the 2.5", but the 1.75" does have quite a bit more friction loss in it. Friction loss from the nozzle, coefficent on the hoses, target flows of each line, and lengths of each hose all cause variation. Some flow testing can help you build a good pump chart and make this simple to reference. One example from my dept's particular set up: 200' of 2.5" with 265 gpm (1 1/8" tip at 50psi) is a PDP of 80 psi. Putting 100' of 1.75" with a 160 gpm nozzle would need a PDP of 90 psi, so a slight increase in pressure is called for in that case.
@ronaldrobertson2332
@ronaldrobertson2332 4 жыл бұрын
@@randyayo2846 He did say two lengths.
@classic_kempii_0078
@classic_kempii_0078 2 жыл бұрын
yes they gotta calculate the friction lost they just gotta add 20 psi so they have the right pressure
@wawansafeonewawan9694
@wawansafeonewawan9694 5 жыл бұрын
Second hose connected no need to layout again, just leave it so then it will pop up by itself then just drag it
Gated Wye Operations - Extended Version (Ep #57 & Ep #58)
10:55
Elkhart Brass
Рет қаралды 19 М.
когда повзрослела // EVA mash
00:40
EVA mash
Рет қаралды 4,3 МЛН
THE POLICE TAKES ME! feat @PANDAGIRLOFFICIAL #shorts
00:31
PANDA BOI
Рет қаралды 24 МЛН
Incredible magic 🤯✨
00:53
America's Got Talent
Рет қаралды 65 МЛН
The art of misdirection | Apollo Robbins | TED
8:48
TED
Рет қаралды 27 МЛН
2 5 inch Hose Handling methods
8:10
Dallas Fire-Rescue Training
Рет қаралды 49 М.
Bill Gustin on Stream Testing
5:39
Fire Engineering
Рет қаралды 14 М.
Nozzle Selection
7:25
First Due Machinists
Рет қаралды 8 М.
History of Fog Attack (Episode #100)
4:55
Elkhart Brass
Рет қаралды 6 М.
Advancing Hose Training Video
4:50
Official Rapid City Fire Department
Рет қаралды 36 М.
когда повзрослела // EVA mash
00:40
EVA mash
Рет қаралды 4,3 МЛН