21- Siemens PLC Redundancy & High Availability: From Basics to TIA Portal Setup and Real HW Test!

  Рет қаралды 7,880

BlocIoT

BlocIoT

Күн бұрын

Пікірлер: 22
@DrReginaldFinleySr
@DrReginaldFinleySr 11 ай бұрын
This was very helpful. It clarified why the HA CPUs are faster than the Redundant CPUs as the R ones must copy over the program. With the HA CPUS, there is no copying needed at interruption, only the switching. Thank you!!
@blociot
@blociot 11 ай бұрын
Thank you for watching 🙏
@kme8134
@kme8134 Жыл бұрын
This is great information. Many thanks for your efforts
@blociot
@blociot Жыл бұрын
Thank you for watching.
@mohammedrezk8072
@mohammedrezk8072 9 ай бұрын
simple and straight forward to the point , thanks
@blociot
@blociot 9 ай бұрын
Thank you for watching
@bachrayoussef
@bachrayoussef Жыл бұрын
Great video. Can one PLC be run standalone, if the secondary PLC is not available yet?
@blociot
@blociot Жыл бұрын
Exactly. The secondary CPU will run without any limitation untill the primary is back online. Thank you for watching.
@jr_electrical-Engg
@jr_electrical-Engg 7 ай бұрын
Can we add switch in in interface port 2 of 1515R
@blociot
@blociot 7 ай бұрын
Sure. The CPU in this deno is connected to a Scalance switch on its right side.
@jr_electrical-Engg
@jr_electrical-Engg 7 ай бұрын
But interface 2 haven't MRP can we connect directly
@blociot
@blociot 7 ай бұрын
@@jr_electrical-Engg I am not sure if I fully understand your concern. You may send us a message on Linkedin to chat more with details. Overall, each CPU has two independent ports (X1 and X2). In this demo, X2 of each CPU is unused. So you may ise it for any purpose. But X2 is not a part of MRP ring so you won't get benefit of MRP ring. Overall, it's not a good idea to do it this way. If you need to add a switch, add it to the ring. Hope this helps
@leosdospel863
@leosdospel863 4 ай бұрын
Hello Thanks for video. Is it possible to have redundant ET200SP with non redundant CPU? Thanks
@blociot
@blociot 4 ай бұрын
I hope it was useful. To my knowledge, you can connect redundant I/O to non-redundant CPUs in PCS7, but there are limitations and considerations. For instance, using redundant Modbus TCP/IP on PCS7 to communicate with non-redundant PLCs is possible but sub-optimal. Additionally, for true redundancy, you would need specific hardware configurations such as HF Interface Modules and S2 PROFINET features to ensure proper communication and avoid single points of failure. Without these, redundancy may not be fully achieved.
@Tevez2367
@Tevez2367 4 ай бұрын
What happens if you have two cpus and three RIO units in project but only one RIO can be connected for commissioning does it have to be setup as in your video? Or can you complete the ring without the other two RIOs ?
@blociot
@blociot 4 ай бұрын
Great question! If RIOs are just a node in the ring not redundant RIOs, they don't have to be connected and can be connected later. But Redundant RIO is a diffefent story. Here is a useful link: support.industry.siemens.com/cs/document/109767576/connection-of-redundant-i-o-devices-to-s7-1500?dti=0&lc=en-WW
@usamashaikh7130
@usamashaikh7130 8 ай бұрын
Brother, i have situation when i tried to download the hardware configuration, it only got downloaded in primary plc and backup plc is empty without the program. can you please the how i can download the configuration and porgram in backup plc. I have follow the hardware wiring the same as you said
@blociot
@blociot 8 ай бұрын
Hi Usama. Have you tried downloading to the backup CPU directly? Try connecting to the backup CPU directly with an Ethernet cable if the TIA Portal doesn't recognize it.
@MrDawen1997
@MrDawen1997 7 ай бұрын
wow did you paid for both the cpu's yourself? quite expansive!
@blociot
@blociot 7 ай бұрын
The demo was borrowed from local Siemens office :)
@MrDawen1997
@MrDawen1997 7 ай бұрын
@blociot thanks for the reply. Didn't that was possible. Do you rent that or need to be a siemens certified partner?
@blociot
@blociot 7 ай бұрын
@@MrDawen1997 anyone who want to buy a unit, they can ask for a demo for testing as long as the local office has a demo available. You should call them and ask.
“Don’t stop the chances.”
00:44
ISSEI / いっせい
Рет қаралды 62 МЛН
TIA Portal: Device vs Network vs Topology View
16:44
Hegamurl
Рет қаралды 26 М.
CPU 1513R Redundancy with Scada and HMI #S71500H
27:18
@utom@tion Tech
Рет қаралды 9 М.
Siemens S7-1500R/H redundant system Part 1 (Architecture &Configurations) - A Complete Architecture
15:01
S7-1500 Redundancy & High Availability Webinar 12MAY2020
55:07
John Skinner
Рет қаралды 18 М.