3-Ph Transformer Differential Protection through numerical relays

  Рет қаралды 53,360

electrical engineerr

electrical engineerr

Күн бұрын

Пікірлер: 59
@fabianm.2982
@fabianm.2982 5 жыл бұрын
You are great Sir, wish I had you as my electrical protection lecturer during my varsity years. You effortlessly make concepts which used to crack my brain look easy. Im humbled!!
@shihabahmedalkatrani3050
@shihabahmedalkatrani3050 5 жыл бұрын
Very nice 👍 and excellent work....go head
@jitendragujarathi1282
@jitendragujarathi1282 3 жыл бұрын
Really great understanding
@shyammohan4868
@shyammohan4868 5 жыл бұрын
Thanks sir. Rarely found explanation for CT connections -Thumb rule .
@Kali9030
@Kali9030 7 жыл бұрын
your videos are very informative and useful, i am waiting for your next video on electromagnetic differential relays. thanks for your time and effort, really appreciate it.
@erisherm.8451
@erisherm.8451 4 жыл бұрын
Well done .Excellent presentation.
@muhammadsajjad1723
@muhammadsajjad1723 3 жыл бұрын
Explained very well
@anwarullakhayoom7863
@anwarullakhayoom7863 6 жыл бұрын
Excellent , very smooth presentation. thanks.
@monudubey2651
@monudubey2651 5 жыл бұрын
Very very nice .we understood very much. thanks
@juniornijiharan8472
@juniornijiharan8472 6 жыл бұрын
Very good explanation and thank lot for your effort.
@ImranKhan-nu6xw
@ImranKhan-nu6xw 2 жыл бұрын
Good job u did ,the 2nd vedio u referenced is not available,plz share link of that
@sharathmsg4436
@sharathmsg4436 5 жыл бұрын
Ur great boss.. Thank u so much . Very usefull..
@milanpatel9939
@milanpatel9939 3 жыл бұрын
Detailed explanation 👏
@unnikrishnanvelu2538
@unnikrishnanvelu2538 7 жыл бұрын
Very good video . thanks
@thamilarasanraju134
@thamilarasanraju134 5 жыл бұрын
Great superb ji.
@manisikhadatta2410
@manisikhadatta2410 6 жыл бұрын
Excellent explanation!
@mrfasil6060
@mrfasil6060 7 жыл бұрын
very good and informative vedio . would you please make a lecture on distance relays .and where i found all vedios uploaded on your channel.
@ATOMSENERGY
@ATOMSENERGY 4 жыл бұрын
Bro I have doubt,in CT secondary connection you are showing mirror image in that connection differential relay connected between R and star point and Delta R phase,in star connection current will flow bcoz of there 2 point available but in Delta only one connection are showing,how current will flow in that one connection,plz give solution
@AH-uj3bc
@AH-uj3bc 7 жыл бұрын
When will you be putting up the diff protection using electromechanical relays?
@carlosavalos622
@carlosavalos622 7 жыл бұрын
excellent video!
@Prashantbaurai
@Prashantbaurai 5 жыл бұрын
Sir u gave the excellent example... Im 100% satisfied.... Can u explain it for electromechanical differential relay.... Please
@riteshpaul5968
@riteshpaul5968 5 жыл бұрын
Bro is the value of Id which is 0.15 amp. in this case is fed by us in the numerical relays,plz reply bro,I m confussed for that,does we have to feed this pick up value of Id in the numerical relays,plz reply bro
@jamest.5001
@jamest.5001 6 жыл бұрын
I have a question. that I hope you will answer for me. does a 3-phase transformer see 180 or 150hz or does it not work that way? the reason I ask. is if you rewound the core as a single phase. would it be optimised for more in the 150-180 hz frequency ? doesn't the laminations need to be thinner on 3-phase transformers? thanks . I hope you can help me with this.
@sjay2630
@sjay2630 7 жыл бұрын
question: trying to achieve +/- 5% of 230v. readings are L1 to L2= 247 L1 to Ground= 122 L2 to L3= 248 L2 to ground=214 L1 to L3= 247 L3 to Ground= 124 I was informed to use 2 buck and boost transformers 500SV43B 0.50kva, what is the wire make up with high leg?
@عليالحارثي-ز8ظ
@عليالحارثي-ز8ظ 6 жыл бұрын
Thanks keep good job
@gunendragujarathi5704
@gunendragujarathi5704 7 жыл бұрын
Excellent.......
@brightstar6587
@brightstar6587 5 жыл бұрын
Sir made some vdos regarding Relay coordination and fault calculation
@rameshsrc4546
@rameshsrc4546 7 жыл бұрын
Hi friend thanks for your nice work. I have a doubt, Why did you marking Y phase current value as i @(240) degree. ? phase angle difference between each phase is 120 degree. then R phase= I @(0) Y phase = I @ (120) B phase = I @ (240) Is it right or not??? But you are mentioned always Y phase is I @(240) ???
@NasirKhan-ek3rt
@NasirKhan-ek3rt 7 жыл бұрын
PLOT FOUR QUADRANT THEN DRAW THESE PHASES. AT 120 DEGREE IF YOU PLOT YELLOW PHASE THEN DURING ROTATION OF PHASES IT WILL BE ACB INSTEAD OF ABC. SO THATS WHY WE TAKE ANGLE FOR YELLOW 240 WHICH IS IN THIRD QUADRANT
@manumanojpeddi3647
@manumanojpeddi3647 6 жыл бұрын
Ramchandra Ramesh if you get answer please send me
@manumanojpeddi3647
@manumanojpeddi3647 6 жыл бұрын
Nasir Khan I didn’t understand,would you explain it clear with a figure
@srinivasbommagani3724
@srinivasbommagani3724 7 жыл бұрын
Nice video sir...can you explain setting consideration in first second slope, after minimum diffrential pick up
@riteshpaul5968
@riteshpaul5968 5 жыл бұрын
Is the pick up value of Id which is 0.15 amp. in this case is fed by us in the numerical relays,plz reply bro
@riteshpaul5968
@riteshpaul5968 5 жыл бұрын
Is the pick up value of Id which is 0.15 amp. in this case is fed by us in the numerical relays,plz reply bro
@ian20662
@ian20662 7 жыл бұрын
Can you kindly recommend a good manufacturer??
@riteshpaul5968
@riteshpaul5968 5 жыл бұрын
Does the numerical relays also have the NO,NC contacts like electromechanical relays????,plz reply sir
@electricalengineerr9711
@electricalengineerr9711 5 жыл бұрын
Yes it has both no and nc contacts
@varadharajanelectricalengi5954
@varadharajanelectricalengi5954 5 жыл бұрын
Awesome thanks
@seenimohmaedimrankhan711
@seenimohmaedimrankhan711 7 жыл бұрын
sir , can u clarify the CT connection ?...while using the microprocessor based relays the CT connections is star, but without micro processor based relay it was different connections like one side delta and other side star?
@nisargchoksi2548
@nisargchoksi2548 7 жыл бұрын
Sir Very Nice Video But i want to know how to test slope charct. of Differential relay
@marudavanansomasundaram8094
@marudavanansomasundaram8094 7 жыл бұрын
Wonderful Explanation.. Expecting clearly explained video of Restraining characterstics/bias and other inhibit function protn in detail for trafos..
@riteshpaul5968
@riteshpaul5968 5 жыл бұрын
Sir is the pick up value of Id is also have to fed by us in the numerical relays,plz reply sir
@electricalengineerr9711
@electricalengineerr9711 5 жыл бұрын
Yes.......it depends on the rating of the transformer.
@rakeshsingh-ed4ws
@rakeshsingh-ed4ws 7 жыл бұрын
VERY GOOD SIR
@12345678sharad
@12345678sharad 4 жыл бұрын
Polarity is missed, you should show it, rest assured it's a good explanation
@sdineshkumar9086
@sdineshkumar9086 7 жыл бұрын
Really the video will be neat but in k2 formula you need to change that's no secondary side CT ratio its primary side CT RATIO divided by full load current
@riteshpaul5968
@riteshpaul5968 5 жыл бұрын
Bro does the pick up value of Id which is 0.15amp. in this case is feed by us in the numerical relays,plz reply bro
@nandikhambholja7138
@nandikhambholja7138 7 жыл бұрын
what is difference bt transformer & generator to provide differential protection? phase angle & magnitude expect other difference ?
@electricalengineerr9711
@electricalengineerr9711 7 жыл бұрын
Transformer has two winding, mostly one connected in star and the other connected in delta. when there is an unbalance in the load there will be flow of zero-sequence current in the lines of star connected side, but there will be no flow of 0 seq current in the lines of delta connected side, thus the differential relay might operate during unbalance conditions, in order to avoid it we use 0 sequence filtering in the star connected side. For generators there is no need to use 0 seq filter. we also use 2nd harmonic blocking in transformers to prevent unwanted tripping of differential relay during magnetizing inrush. for generators we don't need to use 2nd harmonic blocking.
@johnyelengical
@johnyelengical 7 жыл бұрын
Thankyou...
@imconfus
@imconfus 7 жыл бұрын
Why did you divide by the root of 3 at 17:45 isn't the transformer Y connected on that side?
@anwarullakhayoom7863
@anwarullakhayoom7863 6 жыл бұрын
P=ROOT3 X V X I ; I= P/ROOT3 X V ; OK ; This a simple 3 phase power formula for 3 phase networks ,
@vidyasagar1795
@vidyasagar1795 7 жыл бұрын
Nice
@divyakumari6282
@divyakumari6282 5 жыл бұрын
Sir induction motor protection ka video upload kariye plz
@riteshpaul5968
@riteshpaul5968 5 жыл бұрын
For the INDUCTION MOTORS protection,we have to use the DOL starter,if the INDUCTION MOTOR is up to 5 hp,& for the protection of INDUCTION MOTORS more than 5 hp we have to use the star Delta starter or soft starter,WHILE THE BEST WAY IS TO USE A VFD(VARIABLE FREQUENCY DRIVE),THIS VFD NOT ONLY PROTECTS THE INDUCTION MOTORS,BUT ALSO WE CAN CHANGE THE SPEED OF INDUCTION MOTORS,BY CHANGING THE FREQUENCY IN THE VFD.😊😊
@rjrnjn87
@rjrnjn87 4 жыл бұрын
Very informative but small figure
@rakeshsingh-ed4ws
@rakeshsingh-ed4ws 7 жыл бұрын
PLS SHARE YOUR DETAIL
@Actioncomedyclip
@Actioncomedyclip 6 жыл бұрын
In hindi pls.
@nothingaboutme8747
@nothingaboutme8747 3 жыл бұрын
🍐🍐🍐🍐🍐📡📡🔌🔌
Learn the basics of differential protection of Transformers
10:47
electrical engineerr
Рет қаралды 119 М.
버블티로 부자 구별하는법4
00:11
진영민yeongmin
Рет қаралды 21 МЛН
Seja Gentil com os Pequenos Animais 😿
00:20
Los Wagners
Рет қаралды 32 МЛН
She's very CREATIVE💡💦 #camping #survival #bushcraft #outdoors #lifehack
00:26
Differential protection
8:53
stephen brooks
Рет қаралды 136 М.
Transformer Differential Stability
46:48
electrical engineerr
Рет қаралды 19 М.
Zero Sequence Current Filtering for Differential Relay of Power Transformer
8:47
RELAY PROTECTION ELECTRICAL
Рет қаралды 3,4 М.
GENERATOR DIFFERENTIAL PROTECTION
19:15
Electrocean
Рет қаралды 52 М.
UR-121 l Distance Protection Theory v1
22:18
L&D for Protection and Control
Рет қаралды 118 М.
How 3 Phase Power works: why 3 phases?
14:41
The Engineering Mindset
Рет қаралды 1,4 МЛН
Transformer Differential Protection Course [Differential Calculations in Numerical Relays]
13:26
basic theory of REF protection in transformers
10:10
electrical engineerr
Рет қаралды 113 М.
D1 Differential Protection: Basics
6:18
iMooX at
Рет қаралды 60 М.
버블티로 부자 구별하는법4