61 746 IDEAL Clamp Meter

  Рет қаралды 55,995

Ron Kipper From IDEAL

Ron Kipper From IDEAL

Күн бұрын

Пікірлер: 94
@VllKlNG
@VllKlNG 6 жыл бұрын
Great tip on the ammeter. I didn't think about the 2 wires inside the clamp at first!
@RonKipperDatacomm1
@RonKipperDatacomm1 6 жыл бұрын
Hey V King you have a good start to a channel keep going! Ron
@rogerdodger5415
@rogerdodger5415 4 жыл бұрын
Thank you so much! Now I CAN use my meter! And now I like it instead of cussing it!
@RonKipperDatacomm1
@RonKipperDatacomm1 4 жыл бұрын
Use it well Roger! Ron
@ElectricalNick
@ElectricalNick 11 жыл бұрын
Ron, awesome job! Thanks for posting!
@gibsonhouston5285
@gibsonhouston5285 3 жыл бұрын
pro tip: you can watch series at Flixzone. Me and my gf have been using it for watching lots of of movies during the lockdown.
@killianbridger3206
@killianbridger3206 3 жыл бұрын
@Gibson Houston Yup, I have been using Flixzone} for months myself :D
@cashalonzo2641
@cashalonzo2641 3 жыл бұрын
@Gibson Houston Yea, have been using Flixzone} for years myself :)
@Dicofol1
@Dicofol1 12 жыл бұрын
This meter is really fantastic its full of great handy features.
@ChrisHVAC
@ChrisHVAC 11 жыл бұрын
Good looking meter. Just the right size for a service bag.
@SheetRockGirl
@SheetRockGirl 11 жыл бұрын
Wow, what a great video! It was so much fun having the meter right in my hands as I watched your video. You are easy to follow. Each time I thought I had a question you went ahead and answered it in the next sentence. What a blast sticking the thingys on to a 9V battery that was really fun. I had to laugh about blowing the circuit breaker on the hair dryers. You must have a lot of women in your household. Tell them to stay away from the Hot setting, it will fry their hair! Next time I blowdry my hair I am going to be thinking "7 amps" LOL
@eyoabmandefro3673
@eyoabmandefro3673 2 жыл бұрын
I dont know how I did it but I understood everything you said..ive always had a hard time understanding electrical systems. Im an idiot...yet I get it. Thank you sir!!!
@RonKipperDatacomm1
@RonKipperDatacomm1 2 жыл бұрын
Cool glad to help Ron
@beaudraytoncaudill9654
@beaudraytoncaudill9654 3 жыл бұрын
Thank you for making this video and I completely understand my new purchase excited to use it safely
@RonKipperDatacomm1
@RonKipperDatacomm1 3 жыл бұрын
Cool very glad you can use the info have fun Ron
@jfloresX1
@jfloresX1 6 жыл бұрын
Thank you for posting this video, I learned a lot today.
@RonKipperDatacomm1
@RonKipperDatacomm1 6 жыл бұрын
Sounds good glad you could use the info. Ron
@Crozbyguy-rg1iu
@Crozbyguy-rg1iu 21 күн бұрын
Very good explanations, I never used some of the features before. I was also able to use other test leads with special clamps that weren't mentioned on the site, I had some Fluke leads and clamps that really are special grippers. I was hoping to get specific on the banana plug size because that's where it becomes a universal tool for the guy (like me) that bench test things with every lead I have to prove things are working or not. So that's where the banana plug is very important information. Some items aren't available so you mix and match leads.
@RonKipperDatacomm1
@RonKipperDatacomm1 20 күн бұрын
Thanks hope you use the tester well Ron
@MrRubenrivera9649
@MrRubenrivera9649 Жыл бұрын
Hey Ron Ruben here I spoke to your page on Facebook about the 45-113 pliers and no one here has them in their stores yet I am a collector/ fan of that style of pliers I am trying to aquire them to see who's I like the best. If you could post a video of them that would be nice.
@RonKipperDatacomm1
@RonKipperDatacomm1 Жыл бұрын
Hi Ruben I will add it to my list of videos to make they should be available on lowes.com soon. Thanks Ron
@saamejia
@saamejia 10 жыл бұрын
Hi Ron excellent video I have the same clamp meter. But I have a question how you call the device that you plug into the cord extencion and from there you can use you clamp from the meter for test AMP thank you
@cjfilmproductions
@cjfilmproductions 4 жыл бұрын
You can use the NCV button in conjunction with a tone generator to sniff out lines.
@RonKipperDatacomm1
@RonKipperDatacomm1 4 жыл бұрын
Make sure to hold the tip of the clamp meter to the conductors. Use it well Ron
@karleekakes420
@karleekakes420 5 жыл бұрын
could u maybe do a video on the Ideal 61-732?! particularly finding which is the bad Christmas light bulb on a string of lights
@RonKipperDatacomm1
@RonKipperDatacomm1 5 жыл бұрын
Karlee that meter is no longer offered by IDEAL so I won't be doing a video for it. Sorry to disappoint you. Thanks for watching Ron
@abh29569
@abh29569 11 жыл бұрын
great video! I think I'm going to get one of these for school.
@chris81489
@chris81489 10 жыл бұрын
where can I get a little device you put the clamp on for the hair dryer.
@Dicofol1
@Dicofol1 12 жыл бұрын
Ron, I was wondering was is the effective range of the NCV (Non Contact voltage) feature ? For example would it be able to help me locate a live wire behind drywall before I drill a hole or put a nail ?
@Censorship-Eats-Freedom
@Censorship-Eats-Freedom 4 жыл бұрын
Short answer; Very possibly/likely... Long answer; lol , old question that should have been answered years ago, by someone/anyone , hello...???!! lol, so yeah, I would say VERY POSSIBLE, I just tested mine, it starts reading/buzzing at about 5'' / 13cm , most residential wires are going to be within 4.5'' , of the interior drywall surface, and typically , the wires are strapped center of stud at about 2 to 3 inches of the drywall surface.
@scarroll625
@scarroll625 4 жыл бұрын
Thanks for this video.
@RonKipperDatacomm1
@RonKipperDatacomm1 4 жыл бұрын
Hi Hugh thanks for watching! Ron
@lemystere5345
@lemystere5345 3 жыл бұрын
I bought this meter recently and when I try to test continuity between the two leads, it takes some time before it actually starts to sound off a beep, and I see the resistance jumping in the 200-300 Ohms range randomly. I know it only sounds off a beep at under 28 Ohms. If I put the leads tip to tip, it doesn't pick up anything at all. I have to use the middle area or base of the leads' metal needles to get it to work, and it is intermittent. The meter or leads seem(s) weak. Is this normal? I have a cheaper Klein meter (which has its own problems) and it senses continuity almost immediately across the entirety of the metal test-lead needles, even when there is low battery power.
@RonKipperDatacomm1
@RonKipperDatacomm1 3 жыл бұрын
Hi would you send me your contact info and I will try to help Ron at ron.kipper@idealindustries.com
@tinobarbati4944
@tinobarbati4944 2 жыл бұрын
I don't have the instructions so I learned something new. The one I have does not have any sound, is there a volume setting? Thank you.
@RonKipperDatacomm1
@RonKipperDatacomm1 2 жыл бұрын
Tino there is no volume control I have found on some testers they beep but at a high enough frequency that I can't hear it. If your tester is less than 2 years old is should be under warranty. Ron
@tinobarbati4944
@tinobarbati4944 2 жыл бұрын
@@RonKipperDatacomm1 It has a vauge sound which might be what you describe, but I'm not sure if it's reliable. I inherited it, no warranty. I still use everything else. I'm not a home inspector anymore when I had equipment. I just use it around the house, etc. Thank you.
@steadyeddie7453
@steadyeddie7453 3 жыл бұрын
Hey Ron, Which model Ideal meter will perform all the measurements that this 61-746 will do plus read DC amps? Also, whichever meter you suggest does it also have a min/max feature? Thanks
@RonKipperDatacomm1
@RonKipperDatacomm1 3 жыл бұрын
Hey Steady Eddie the 61-747 clamp meter woyuld be the next step up AC and DC Amps up to 400A and yes it has a min/max function have fun Ron
@steadyeddie7453
@steadyeddie7453 3 жыл бұрын
@@RonKipperDatacomm1 Thanks Ron for directing me to the 61-747. I picked up one last night. Looking forward to using it for both residential work and on vehicles (particularly the DC current function for finding parasitic draws). Cheers.
@titaniumRV1
@titaniumRV1 12 жыл бұрын
Does this Clamp on meter test dc amps or just ac amps?
@danbonick1723
@danbonick1723 11 жыл бұрын
very informative videos, keep up the good work
@bikersoncall
@bikersoncall 2 жыл бұрын
Good tutorial. One thing that is absolutely counter intuitive for me is the fact that when the 'A' symbol is gone you are in auto range, not out of auto-range. I get what their thinking was, I just think it's reverse logic, especially considering the APO acronym is on when you are in APO (Auto power-off). I've had this unit for many years, great meter, also the NCV (Non contact voltage indicator) is a nice feature to have. The only grudge for me would be that it doesn't read DC amps, not a huge deal though.
@RonKipperDatacomm1
@RonKipperDatacomm1 2 жыл бұрын
Hello maybe we should have your input on the next version appreciate the input Ron
@bikersoncall
@bikersoncall 2 жыл бұрын
@@RonKipperDatacomm1 OMG, triggered by an opinion?.. ✔🍕..and the fallacy in the logic was...? Envelope please..
@SMAzone01
@SMAzone01 8 жыл бұрын
sir .. when use clamp meter where set wire in clamp .? because when wire in clump value is different from different side .
@RonKipperDatacomm1
@RonKipperDatacomm1 8 жыл бұрын
Hello! The readings should be very similar wherever the wire is in the clamp. Keep in mind you can only clamp around the Hot or Neutral not both. If you are getting a big difference something else may be wrong. Take care.Ron
@Censorship-Eats-Freedom
@Censorship-Eats-Freedom 4 жыл бұрын
The best amperage readings from my experience have always been having the wire you are tesing as close to center of the clamp as possible, though if you can't get the wire off the panel wall very far, you can still get a fair reading , by at least getting the wire inside the clamp and clamp fully closed.
@gizmobently
@gizmobently 7 жыл бұрын
Hi Ron, Just started to look for multi-meters and wondered if this is same thing? I am not an electrician but needed to test some electrical parts to see if current was going through it or not. I realize I could buy anything but happened upon one of these at a good price. Will this do all the functions like a multi-meter? I realize they are all different, but many times I work on electric powered miter saws and have to fix the laser part of it which has a separate power supply and have to see if these are bad or not, or is it the on off button for the laser, or is it the connections going to the laser itself, or is it the laser. Is this the tool I need for this type of testing? I really am having a hard time even finding anyone who even knows how to fix these let alone diagnose the issue which has brought me here by chance in looking for a multi-meter. I appreciate any info you can give me.thanks
@RonKipperDatacomm1
@RonKipperDatacomm1 7 жыл бұрын
Hi Greg the big difference between a clamp meter like the one in the video and a multi-meter is how they measure amperage. As the name imply's a clamp meter clamps around a conductor and it reads the magnetic field generated by the current flowing through the wire and can measure higher amounts of amperage were a multi-meter using the test leads has the current flowing through the meter and generally is limited to about 10 Amps. From what you are saying a multi-meter might be a better choice. Good luck Ron
@offgridmangogrower
@offgridmangogrower 2 жыл бұрын
What meter do you suggest for testing dc amps for pv outputs? Most have a max 10 amp circuit ….such as flute.
@RonKipperDatacomm1
@RonKipperDatacomm1 2 жыл бұрын
61-415 Fork Meter if wanting a slide over style meter or a 61-347 multimeter if you want to measure accurately down to milliamps DC current. But the accuracy of the 415 would be less at lower amperages. What’s the total range and what is the active voltage with the current??
@offgridmangogrower
@offgridmangogrower 2 жыл бұрын
@@RonKipperDatacomm1 thanks for the reply I came across a bunch of used panels to be tested so the amps reading needs to be 10% accurate or better….from 8 to 15 amps…volts around 30 to 50.
@offgridmangogrower
@offgridmangogrower 2 жыл бұрын
I have /had a love affair with your 61-702 till she stopped working….left it out over night…and may have got moisture inside….any chance it’s repairable?
@MrMultitool
@MrMultitool 10 жыл бұрын
Thats really a nice meter
@micwell2247
@micwell2247 5 жыл бұрын
Does or will the clamp measure DC ?
@RonKipperDatacomm1
@RonKipperDatacomm1 5 жыл бұрын
DC Voltage but not DC amperage. Hope that helps Ron
@mkjt88
@mkjt88 7 жыл бұрын
Hi Ron I have a like new 61-732 clamp meter which I haven't used in a number of years. Went to grab it the other day and it's dead.. tried new batteries gave it a once over and nothing fixes it. Any idea on what could be wrong. I did take it apart and realize there were no fuses. Just don't understand what it could be it's like brand new used it a few times in a class and been stored inside ever since. Thanks
@RonKipperDatacomm1
@RonKipperDatacomm1 7 жыл бұрын
mkjt88 I am not sure what could be wrong with the meter. It has a 2 year warranty but it sounds like it is older than that. Can you take a pic of the front and back and send it to ron.kipper@idealindustries.com? There is a date code on the back which will tell me how old it is. Maybe we can work something out. Thanks Ron
@mkjt88
@mkjt88 7 жыл бұрын
appreciate it Ron email is sent. And yes I believe I bought it around 08-09 when I did my hvac course and just always used my bigger ideal meter since then for various things as I didn't pursue the hvac career. Anyway thanks a lot
@TomXPorter
@TomXPorter 3 жыл бұрын
I had a similar situation: meter DOA after not using for a while. If you take the back of the meter off (not just the battery hatch) you will find that there are two small square pieces of metal with a finger of metal that connect the coiled springs in the battery tray to two matching pads on the PCB. In my meter, I found that I must have had some minor leakage from the battery that was not visible, but this caused corrosion on one of the pieces of metal. I carefully slid out the corroded connector from behind the battery spring and used very fine grit sand paper to remove the corrosion. Reinserted the connector in the battery tray and meter works fine again. NOTE: I did not touch anything on the PCB or the “guts” side of the meter, only the back cover of the meter that contains the battery tray. Hope this helps!
@mrpush2855
@mrpush2855 8 жыл бұрын
Am I able to see more than one decimal place for DC voltages? This display is 4 places can i change it to show multiple DC voltage decimal places?
@RonKipperDatacomm1
@RonKipperDatacomm1 8 жыл бұрын
Hi mrpush p no you cannot change that on the meter. If you need to read small amounts of DC I would recommend you using a digital multi-meter instead. Good luck Ron
@mrpush2855
@mrpush2855 8 жыл бұрын
Ron Kipper Datacomm Thanks Ron...I wish they would have made it do more decimals there so I didn't need another meter! Maybe by design, who knows. Thanks!
@leewatson007
@leewatson007 9 жыл бұрын
I tested a 110 electric fence and my meter has gone blank. The ncv still makes noise and lights up and the batteries are good. Could I have blown a fuse in it? Any ideas? Lee
@RonKipperDatacomm1
@RonKipperDatacomm1 9 жыл бұрын
+Lee Watson Lee there is no fuse in the meter and it is a Cat III rated tester and designed to be used inside the building in all the branch wiring and inside electrical panels. The fence may have damaged the tester. Send me an address to my ron.kipper@idealindustries.com email and I will send you a slightly used but functional meter to replace it. I have a couple I'd be willing to part with. I will take care of it for you. have a good night and thanks for watching.Ron
@willieyoung3632
@willieyoung3632 6 жыл бұрын
@@RonKipperDatacomm1 where can i get thee brass battery end with spring or without the spring?. Mine has broken broken.
@willieyoung3632
@willieyoung3632 6 жыл бұрын
It's a ideal 61-746.. Thanks
@IchaoticsI
@IchaoticsI 6 жыл бұрын
got this tester as a part of a starter kit for school, but the test leads tester part is too small in length to stick into a socket for a reading, is there different ones or can I peel back some of this plastic?
@RonKipperDatacomm1
@RonKipperDatacomm1 6 жыл бұрын
The tips of the test leads can be pulled off if you need to. They are included to help make the tester Cat III rated. Just put them back on for future testing. Ron
@IchaoticsI
@IchaoticsI 6 жыл бұрын
Thanks! just realized this today lol
@alexandergilcano4223
@alexandergilcano4223 5 жыл бұрын
buenos días necesito el desplaye de la pinza 61-702 soy de Colombia
@RonKipperDatacomm1
@RonKipperDatacomm1 5 жыл бұрын
Hi Alexander we have not made the 61-704 for several years now and we do not have any replacement parts. The current model is the 61-704 if you are interested. Ron
@rogeliocarranza6868
@rogeliocarranza6868 4 жыл бұрын
Thank you very much, although I have an "ideal 61-702" I got the idea
@RonKipperDatacomm1
@RonKipperDatacomm1 4 жыл бұрын
OK use it well Ron
@ibarrera200
@ibarrera200 8 жыл бұрын
my ideal meter is not working on low voltage and continuity what can I do where can they fix it thank you
@RonKipperDatacomm1
@RonKipperDatacomm1 8 жыл бұрын
isidoro have you checked you test leads and replaced the battery? Those are the first things to check. How old is your meter? It comes with a 2 year warranty but you will need your prove of purchase. If that is the case send me your info to my ron.kipper@idealindustries.com email and we will get an RMA going for you. Ron
@ibarrera200
@ibarrera200 8 жыл бұрын
Ron Kipper Datacomm I bought it about 5 years ago but it was only sitting on my garage so I don't know there's a place where I could send it and and have it fixed if you could help me with that everything
@RonKipperDatacomm1
@RonKipperDatacomm1 8 жыл бұрын
I doubt it can be fixed but send me your contact info to my email and I'll see what I can do for you. Ron
@ibarrera200
@ibarrera200 8 жыл бұрын
Isidorobarrera@hotmail.com
@betobeto1971
@betobeto1971 12 жыл бұрын
THANKS
@kc2972
@kc2972 2 жыл бұрын
I don't understand why you would want to use the 10x scale on amps? Why get a reading that is gen times higher than actual ?
@RonKipperDatacomm1
@RonKipperDatacomm1 2 жыл бұрын
KC to try and get a more accurate reading of very small amounts of amperage. You are right in most cases you would not need it. Ron
@gabrielguerro8449
@gabrielguerro8449 2 жыл бұрын
IDEAL INDUSTRIES CAN YOU DONATE A REFURBISHED 61- 763
@RonKipperDatacomm1
@RonKipperDatacomm1 2 жыл бұрын
Gabriel we do not repair them so I do not have any units I can donate to you. Sorry Ron
@x60hz
@x60hz 4 жыл бұрын
Don't store these with the batteries in them. I put mine away for a couple of years as I moved and no longer needed it. Today I did need it, went into my toolbox and after putting fresh batteries in it... nothing. Completely dead. A hundred bucks out the window.
@RonKipperDatacomm1
@RonKipperDatacomm1 4 жыл бұрын
hi x60hz as a general rule if you are not going to use the any tester for that long of a period removing the batteries is a good idea. Ron
@Censorship-Eats-Freedom
@Censorship-Eats-Freedom 4 жыл бұрын
@@RonKipperDatacomm1 Ron, he didn't say the battery leaked, if it didn't leak , and is not going to leak, why would that be a good idea? Does a battery that doesn't leak create a problem with the meter while it is stored? I haven used my meter for about 5 or more years, forgot I had it. Just took it out and works fine, with the battery that was in it for that period of time.
@Censorship-Eats-Freedom
@Censorship-Eats-Freedom 4 жыл бұрын
Great, learned a lot about a meter I've had for 10 years, lol,,,,
@RonKipperDatacomm1
@RonKipperDatacomm1 3 жыл бұрын
Thanks for watching! Ron
@Censorship-Eats-Freedom
@Censorship-Eats-Freedom 4 жыл бұрын
Is there an adjustment inside so I can recalibrate ohms zero-resistance point, right now it reads about 2 ohms , when it should be reading zero.
@RonKipperDatacomm1
@RonKipperDatacomm1 3 жыл бұрын
Hello sorry for the delay there is no way to adjust that. In resistance the accuracy is 1% so it may not always zero out. Have fun Ron
@betobeto1971
@betobeto1971 12 жыл бұрын
THANKS
Sure Trace Circuit Tracer Video Short
2:05
Ron Kipper From IDEAL
Рет қаралды 2,6 М.
Why The Clamp Meter Is The Only Tester You Need | Pros and DIYers
8:12
Everyday Home Repairs
Рет қаралды 666 М.
А я думаю что за звук такой знакомый? 😂😂😂
00:15
Денис Кукояка
Рет қаралды 6 МЛН
Twin Telepathy Challenge!
00:23
Stokes Twins
Рет қаралды 139 МЛН
🇺🇸IDEAL 61-747 vs. 🇺🇸FLUKE 376  ( Features Comparison)
18:52
The Electricians Tools (Review) Channel
Рет қаралды 8 М.
How to use a multimeter like a pro, the ultimate guide
12:55
James Gatlin
Рет қаралды 2,5 МЛН
Cheapest Multi-meter comparison, Which is the Best Value?
12:28
How To Measure Your Amp Load Using a Clamp Meter | RV Must Have
15:23
How to use a multimeter like a pro - Clamp meter
24:52
The Engineering Mindset
Рет қаралды 306 М.
A Meter with an Ideal Price
12:22
tcpHVAC/R
Рет қаралды 17 М.
EEVblog 1622 - The BIG BEGINNER MISTAKE with Multimeters
12:25
Review and Teardown of a Kaiweets HT208D Inrush Clamp Meter
26:00
How To Use A Multimeter for Home Repairs and Troubleshooting
12:31
Everyday Home Repairs
Рет қаралды 1,7 МЛН