How can I download the slides? Is there any book or article I can read and learn more?
@ABBdrivesUS7 жыл бұрын
Hey Vahid, thanks for commenting. You can get a copy of the slide deck here - goo.gl/0gSRLz
@blasemmanuelvillarino17544 жыл бұрын
@@ABBdrivesUS thank you so much i need this for my report
@kakadiatalshi54427 жыл бұрын
Please be noted that Higher capacity transformers has comparatively Low impedance but not the higher impedance and that's why it exhibit low voltage distortion against same harmonic current Bcoz V=ZI , so less the Z, less the V@same I . In the video you stated that higher capacity transformer has higher impedance which needs to be corrected otherwise nice lecture. Thank you.
@altuber99_athlete3 жыл бұрын
Correction @ 1:25 To be specific/accurate, actually harmonics *are* sinusoidal voltages and currents. Their *sum* is what results in a non-sinusoidal voltage or current.
@ervivekchoubey6 жыл бұрын
Thanks for this superb presentation. As an electrical engineering undergrad, I had some doubts regarding harmonics and its effects. By the end of the video, I learned something.
@FrozenArchLich8 жыл бұрын
I'm in the middle of making a switching PSU. What I've just heard is extremely helpful to my job. Thank you for sharing valuable knowledge. ^_^
@alexanderyousefian31865 жыл бұрын
Jeff really great and informative video, just recently had to sink my teeth to all of this information dealing with harmonics and this was a great video explaining some of the main concepts. Keep up the great work!
@niallstone956310 жыл бұрын
Great video Jeff, thank you.
@johndunston23943 жыл бұрын
Very nice presentation. Thanks
@DaneDuPlessis11 жыл бұрын
Helpful insights, thanks Jeff.
@ABBdrivesUS11 жыл бұрын
Thanks for sharing - hope the video was helpful!
@sankareee935 жыл бұрын
Thank you very much this very important lecture about harmonic i really like this lecture
@garbo89622 жыл бұрын
Retired from a large hospital and never know they are held to a tighter voltage distortion. Had hundreds of drives from 3 to 1750 HP and our great start up tech said that we were the only place that had equipment on line side & load side of most drives dealing with harmonics and voltage distortion. About 5 years ago at an IAEI class they said Japan is experimenting with supplying DC panels to large buildings. This would eliminate the need for rectifier and cheaper power supplies to equipment and reducing air conditioning loads. Think they hope to save at least 5% over all between power & AC savings.
@mattaparthisrivenkateswara70213 жыл бұрын
Very good and simple for understanding thank you
@pareshpatel73853 жыл бұрын
Nice topic Will you please describe effects of non linear loads on DG sets as when ever I operate non linear load from grid to DG lod has variation in kw but still incoming DG voltage was not so varying
@aatirehrarsiddiqui88944 жыл бұрын
Great video. Neat and articulate.
@enjay21399 жыл бұрын
Great video, but one thing I observed that most of the time the slide was not shown while you were pointing to the slides, making it missed out what you were trying to show. The camera was focused on you instead of the screen. Can you fix it please? or is it too late.
@yehiaelrifai25455 жыл бұрын
Do you recommend to avoid VFD operated large chillers in data center application?
@busraahmed17082 жыл бұрын
ABB means please
@Muck-qy2oo5 жыл бұрын
And how do subharmonics work?
@JohnSmith-ed1sr6 жыл бұрын
How are you determining Voltage distortion by looking at the current waveform. In the begining you explain the calculation for ITHD then magically 30 seconds latter in the transformer comparison slides you come up with a voltage distortion value with no explanation of how you got it
@tacarn8 жыл бұрын
Can harmonic distortion be generated from poorly designed generators? (alternators) Say for instance, from a poorly designed wind generator that had harmonic content?
@soamdathroopnarine34816 жыл бұрын
yes . you can filter circuit on generator output
@RonAskey10 ай бұрын
@@soamdathroopnarine3481can you explain that more to me please I have a 13000 predator generator. I’m trying to lower THD levels from 23 to 5 percent.
@MrYasir9669 жыл бұрын
very helpful, many thanks Jeff.
@garbo89622 жыл бұрын
Two things: Do 18 pulse VFD'S produce or handle harmonics better then they standard 6 pulse drives? Read some where that some cheap cheating china LED'S have a low power factor as low as 0.5 . Do such low power factor LED''S produce more harmonics then one say above 0.9 PF?. Tech from two separate drive companies said to stay away from 18 pulse drives but we have a lot of them in a new 12 story building ( all drives 30 HP & higher have 18 pulse drives except for soft start on 200 HP fire pump ). Do the newer think they are called active line reactors with their contactors & capacitors much better then plain Jane line reactor? Thanks for nice vid.
@mikemiller55347 жыл бұрын
Great video! Thanks Jeff
@sri2796 жыл бұрын
Thank you very much for uploaded this..
@josephidehen12910 жыл бұрын
Great presentation!
@thangapandiarajapandian17414 жыл бұрын
Great Video, Thank You
@AlexTian-199011 ай бұрын
Good Video!
@mohdredduanmaddom71609 жыл бұрын
great video jeff , make me more understand on harmonic
@deokagusti89818 жыл бұрын
Very helpful! thanks Jeff
@sohailjanjua1234 жыл бұрын
Hi Jeff, I like youe lecture
@SafeAndEffectiveTheySaid11 жыл бұрын
Thank you!
@JewMonGee4 ай бұрын
are harmonics also known as dirty electricity or dirty power harmonics is the harmful radiation that comes from dirty electricity right smart meters produce harmonics right
@APprojection8 жыл бұрын
Thanks a lot, very useful
@omidash2677 жыл бұрын
I was thinking 70 + 20 = 90, Today I learn 70 + 20 = 72, and it responded to all my THD Math I knew before :)
@ahmedosman96997 жыл бұрын
actually you should 1. square both of them 2. add them 3. square root the result and you will ger 72.8 so called rms (root mean square ) try it :)
@XTRMJ6 жыл бұрын
I just looked at this video & I had the same concern. I think he meant to use only "2 amps" instead of 20, & thus 2/70 = 2.857%, otherwise 28.57% is way higher than their worst case THD. But considering he represents ABB, they should have fixed all of these discrepancies by now.
@mwsc5 жыл бұрын
You can see the formula for RMS at 4:35 I(total) = sqrt (Ifund^2 + Iharm^2) = sqrt (70^2 + 20^2) = 72.8A.
@othusitselokailwe28577 жыл бұрын
Nice presentation but we are more interested on what he is explaining. Now you guys are showing more of him instead of the slides
@ABBdrivesUS7 жыл бұрын
Hey Othusitse, thanks for letting us know. You can follow along with the slide deck here - goo.gl/0gSRLz
@BlueLightRhyno3 жыл бұрын
Thnks!!
@DiabloManiacz6 жыл бұрын
8:15 is that so? :thinking:
@franciscocoelho4623 жыл бұрын
I think this is the opposite. A higher power transformer presents lower impedance.
@alexl.94326 жыл бұрын
BOOK: POWER SYSTEM HARMONICS AND PASSIVE FILTER DESIGNS J.C. DAS DOWNLOAD FREE: mundoemorendedordigital.blogspot.com/p/power-system-harmonics-and-passive.html
@RamaDevi-zm2rx2 жыл бұрын
Recent disasters due to harmonies
@reysee2 жыл бұрын
I enjoy Chris Pratt talking about harmonics.
@jesterraj7 жыл бұрын
can a generator create harmonic distortion?
@nirbhaythacker66627 жыл бұрын
It depends on the design of the generator, but generally generators do not produce any significant harmonics. You could read up a better explanation from "Electric Machines" by Ashfaq Husain.
@MR-nl8xr8 жыл бұрын
55 Deg. that's freaking cold.
@erikhastenreiter16763 жыл бұрын
good nice
@jfrjr79644 ай бұрын
😮
@imeprezime12853 жыл бұрын
Power factor and voltage drop. If these are acceptable I don't give a damn for harmonics
@michaelbee82638 ай бұрын
Well bad harmonics will give you bad power factor
@imeprezime12858 ай бұрын
@@michaelbee8263 Not necessarily. For instance, if you have square voltage and square current waveform, the power factor can be 1, but spectral analysis will show plenty of harmonics
@michaelbee82638 ай бұрын
@@imeprezime1285 a square wave? This video is a power application.