-Our Website has FREE Videos, Calculators, Podcasts, Articles, Tips, Quizzes, Q/A: www.acservicetech.com -Facebook Tips: facebook.com/acservicetech -Tools we use, Our Book, Workbook, and Quick Cards: www.amazon.com/shop/acservicetech -Our E-book, Paperback, Workbook, Quick Cards, Powerpoint, www.acservicetech.com/ac-book -Our E-book: play.google.com/store and search "ac service tech" -Spanish Book & E-book: www.acservicetech.com /store -Join our updates list for an email strictly from us for new videos, articles, products and website features! www.acservicetech.com
@rayanbraydon533 жыл бұрын
Sorry to be so off topic but does anybody know of a way to log back into an Instagram account..? I stupidly forgot the account password. I love any tricks you can offer me!
@yehudabrennan94203 жыл бұрын
@Rayan Braydon instablaster ;)
@rayanbraydon533 жыл бұрын
@Yehuda Brennan thanks for your reply. I found the site on google and Im in the hacking process now. Looks like it's gonna take quite some time so I will get back to you later with my results.
@rayanbraydon533 жыл бұрын
@Yehuda Brennan It did the trick and I actually got access to my account again. I am so happy:D Thanks so much, you saved my ass !
@yehudabrennan94203 жыл бұрын
@Rayan Braydon happy to help xD
@johncarcamo67724 жыл бұрын
Seriously you did better than my gas furnace teacher.
@acservicetechchannel4 жыл бұрын
Glad it was helpful for you, thanks!
@abeltaura489422 күн бұрын
I paid 12k lol
@veteranjeeper11204 жыл бұрын
These videos you make ,have helped me become a better tech and great for touch on on knowledge!
@acservicetechchannel4 жыл бұрын
Great to hear!
@naturestrail229623 күн бұрын
I'm sitting here trying to figure out why my thermal switches have 120v? It's a 1979 Ruud heat pump I believe. Also been trying to figure out why there's a grey wire no label, blue wire labeled B, and no orange wire? No telling who's worked on it in the past when the thermostat was changed by the previous owners. Also, when it's set to heat pump it has electric arches jumping between a couple contacts you can hear inside the air handler. When you set it to EM heat this goes away. Any help will be greatly appreciated! Thanks
@TrollinTheInterwebs4 жыл бұрын
I like watching your videos, keeps me from getting rusty.
@acservicetechchannel4 жыл бұрын
Glad you like them!
@vetdadcubby47224 жыл бұрын
Simple, effective and professional!! Great job sir!
@acservicetechchannel4 жыл бұрын
Thank you kindly!
@aaronr1644 жыл бұрын
I wish there was someone like you to explain commercial boilers
@izzymoney854 жыл бұрын
I like to say Thanks for a very well done video this is something the new guy can benefit from bye learning a simple way of doing things keep up the good work 😎
@acservicetechchannel4 жыл бұрын
Thank you very much Esmar!
@tytig944 жыл бұрын
I freaking love your videos, they make my life easier. Thanks!
@acservicetechchannel4 жыл бұрын
Glad you like them!
@Dalewdone4 жыл бұрын
Great video. Answered my question a while back about using the dollar bill to clean the flame sensor.
@acservicetechchannel4 жыл бұрын
Glad to help
@RayRay-nb7tn4 жыл бұрын
Great video on gas furnace safety switches. Haven't been commenting lately. Been busy with friends Sprint car racing. Season ended so back to the grind again. Thank you for the videos. Be safe.
@acservicetechchannel4 жыл бұрын
Thanks, you too!
@RayRay-nb7tn4 жыл бұрын
You are very welcome. Thank you.
@ShelterG4 жыл бұрын
I would like to add on more method. Measure voltage between limit connectors. If O volt means no voltage drop and limit is good. If 28 volt means open circuit - bad limit.
@acservicetechchannel4 жыл бұрын
Great tip Eugene!
@farmthug00853 жыл бұрын
Thanks for the tip. I'm new to HVAC but it's all starting to come together
@jimmysegovia26884 жыл бұрын
thank craig for sharing! all your lessons are really awesome! i have been watching and learning from the start with your videos thank you so much for sharing.
@acservicetechchannel4 жыл бұрын
You're very welcome!
@johncarcamo67724 жыл бұрын
Thanks for the clear explanation
@acservicetechchannel4 жыл бұрын
Happy to help
@petebuehn77893 жыл бұрын
Thanks for the great video, helped my solve my problem!!
@acservicetechchannel3 жыл бұрын
Glad it helped!
@joemikhaiel37104 жыл бұрын
Thanks for sharing the knowledge
@acservicetechchannel4 жыл бұрын
So nice of you
@acrepairnearme4 жыл бұрын
Great topic. Sometimes I do this to check automatic reset limits. Just to make sure it is in working condition. I’ve put the flame from the lighter(blue part) and warming up limit switch metal shield till it will click, and make it OL, and then waiting for it to cool down and click back. Another technic: if I see that the igniter won't go ON, I jump the pressure switch just a few sec later after the inducer starts, and then if the igniter starts to light up, I know the problem is most likely related to the pressure. The switch itself or clogged tube.
@acservicetechchannel4 жыл бұрын
The only thing is those switches are built so small and precise that I really would not put a flame to it to test it because it may overheat especially the alum shell on the outside and it may warp causing pressure on the bimetal disc. I have done it in the classroom to fault a furnace for a student for the flame rollout switches but I wouldn't put that heat on those in the field. Hope you don't mind me saying and thank you for your support!
@alfredoalvarez151011 ай бұрын
Very good explanation, thanks 😊
@luiselizalde67574 жыл бұрын
As always excellent explanation., Thanks.
@acservicetechchannel4 жыл бұрын
Glad you liked it!
@tinysand35174 жыл бұрын
another great one Greg
@acservicetechchannel4 жыл бұрын
Glad you enjoyed it
@mikimiki1952 жыл бұрын
Great video Sonic you reading voltage on switches. That means switches are good
@alexismcmackin3 жыл бұрын
Yes, more of these!
@deanmartin19664 жыл бұрын
Great video, thanks for sharing
@acservicetechchannel4 жыл бұрын
Thanks for watching!
@jonathanraul40864 жыл бұрын
Thanks great video once again
@acservicetechchannel4 жыл бұрын
Glad you enjoyed it
@cri8tor3 жыл бұрын
Great tutorial. Cheers
@acservicetechchannel3 жыл бұрын
Glad you liked it!
@cri8tor3 жыл бұрын
I have a Goodman GMP075-3 furnace, installed in 1997. My AC and Heater are off at the thermostat. Fan is on Auto. The blower fan in the furnace turns on for a few minutes randomly almost everyday. Could that be a Fan Limit Switch issue? Will go into the attic and check some of the switches when it cools down. Cheers
@thecreativehuman752 жыл бұрын
You are by far the BEST HVAC instructor on KZbin! Do you have a book ( aside from your AC book) designated to service trouble shooting? Many thanks for all you do.
@ParabellumX2 жыл бұрын
Modern Refrigeration and Air Conditioning, 21st Edition, by Althouse/Turnquist/Bracciano. This is the HVACR Encyclopedia.
@melo86684 жыл бұрын
Awesome information awesome channel !
@acservicetechchannel4 жыл бұрын
Thank you!
@AceMoney-Sportsbook-Robbery2 ай бұрын
I have a Luxaire older model - I have decent knolwedge from troubleshooting this furnace over the years . I was having trouble remembering what i did a few years ago to get it running correctly. I had to change and fix a few different sensors , limit switch & a Capacitor for the blower motor. basically all the stuff you just went over.. I came across your video.. quick easy and right to the point. quick refresher coarse . I got a limit switch issue I think ( 4 Blinks on my modle) Ill go test them now.. thank you.... Quick question if you see this "OL" that means its bad the ones with the button in the middle/ they should read 0.00 right ? ohms
@bradmironik61374 жыл бұрын
Glad to know another means of testing switches. I thought you can test across the limit and find out if the switch is opened/closed via voltage readings (24v/0v). Correct me if that is not correct.
@johnnynguyen38383 жыл бұрын
Is it on specific furnace that you have power across these safeties while the furnace is idled? (Power is ON but no call for Heat)
@bauhnguefyische6674 жыл бұрын
Always a simple explanation here on how ‘hopscotch’ works with a electric meter.
@Millennmify2 жыл бұрын
Showed me how to test the switches. Found that the thermal limit switch was open showing no ohms. Replaced switch and Goodman furnace works again.
@MrMasoud9114 жыл бұрын
Hi Craig and thanks again for your great videos, just a novice question, if we disconnect the power to the furnace, how come we have voltage on those switches? Thanks again
@acservicetechchannel4 жыл бұрын
There is power to the switches even when there is no call for heat, thanks!
@MrMasoud9114 жыл бұрын
@@acservicetechchannel alright, thanks
@RC-ud9hh2 жыл бұрын
Wow you blew through that lesson! Just throw this novice right into the furnace fire and repeat. 😆
@Karnol4282 жыл бұрын
Are all gas/ propane low voltage systems common connected to the ground?
@abnergarcia62524 жыл бұрын
What would happen if you touch the flame sensor with power on? I always clean them but remove the wire first. Sometimes the wire spade connected is bare metal and is not insulated. I wondering if there is a risk of getting shock. The furnace is power on but there’s no call for heat at the time I cleaning it.
@TheMaster51504 жыл бұрын
If there is voltage going to the flame sensor when touching the spade with one hand, and you touch something grounded with your other hand⚡....just like the test he did with the meter to get a reading. I've seen retards pinch wires with meters and bump into something grounded and get shocked🤯
@abnergarcia62524 жыл бұрын
@@TheMaster5150 is voltage only going through flame sensor when there is a call for heat? Or after burners are lit?
@TheMaster51504 жыл бұрын
@@abnergarcia6252 When the door switch is in the closed position, there should be power to the flame sensor, safety switches, transformer, board...etc. He has a magnet, or tape on the switch to perform power test without any calls. With the door off the switch, you shouldn't be getting power. Fwi...I was taught with 3 phase, and 240v check each leg to ground, even if your not getting a reading from leg to leg because you maybe reading the same potential "no difference" between the probes as the polarity could be the same. My point is...if you're not 100% sure, aways check to ground, and a beeping volt tester first, because Doctor's have found getting shocked causes scarring to the heart.
@acservicetechchannel4 жыл бұрын
Yes power is on any time the door switch is shut and power to the furnace. Thanks for answering TheMaster5150!
@johnharrisonschulz2 жыл бұрын
You forgot to show where the high limit switches are in the blower compartment. Some furnaces have manual reset limit switches in the blower compartment too.
@cck07283 жыл бұрын
As usual excellent video. So, it means that switches can be checked via resistance and voltage? Voltage should be same across and resistance should be "zero". Thanks.
@martineucza4864 жыл бұрын
How do you test switches and flame sensor rod with the furnace on?
@wxfield Жыл бұрын
Why are you using the red lead for your ground?
@robertcherry49712 жыл бұрын
What is the best way to test a high limit switch while in furnace,to prove what temps it is opening and closing at?
@Krystle161 Жыл бұрын
Hello! I ran into your video because my inducer motor isn’t starting. There is no flashing light on my furnace though. Just a solid light. I tested each of my 3 limit switches and for one of them, one plug is giving 28v and the other is giving 0.03v. I also tested the pressure switch when calling for heat and both are giving low voltage. Any thoughts and advice? Thank you!!!
@l.a.m7645 Жыл бұрын
Flame rollout switch and spill switch the same?
@EclecticLensYT3 жыл бұрын
So.. how to do you test the ignitor?
@Kkayoodle3 жыл бұрын
I have an older Carrier/Payne 3 wire auto pilot ignitor type furnace. I wanted to see if you could tell me how I can tell the diff between my limit switch & flame roll out switch? Most videos I watch have either a button pop type limit switch or a 2 longer pronged limit switch. Problem is I have both. So I'm thinking one of them may be a flame rollout switch but I can't tell. The parts # on it is smudged so couldn't look it up to verify what it is. Ty
@DylanTonoguva Жыл бұрын
How do I check air combustion temperature sensor in my rinnai hd200e hot water heater?
@domas44632 жыл бұрын
Is this multimeter good for checking resistance of a/c thermistors? (kilo ohms) Thanks
@alfredsosa243 жыл бұрын
Hi I having problem to check a furnace with limit switch open that I think is not the limit switch I want to know what to check in order to fix the issue
@johnnynguyen38383 жыл бұрын
It makes sense that the safety sensors should have power going through them when there's power to the furnace. However, I have come across furnace that is powered and no power to the safety sensors. Which is why I asked my question above/below.
@Seabass1206 Жыл бұрын
how will the censors possibly trip if there’s no current running through? im no expert but it sounds like someone jumped the safteys
@zeeshawn15 Жыл бұрын
I was always told to not call 24volt's common a ground... ground should be reserved for 120 volts, while 24 volt should be called common.
@parneypotsАй бұрын
👍👍
@ozarusa192 Жыл бұрын
I have HEIL 96% furnace that is shutting down after about 6 - 7 minutes completely , including thermostat. Code call for limit switch i replaced switch but it still does the same thing, it does it only when required longer operations to bring heat in home for like 3 to 4 degrees up. Acts like its overheating. Fan blows after shutdown for about 3 minuts and restars heating cycles and works again for same amount of time 5:37 6-7 minutes and shuts off. Air flow is good and clear clean filter. I checked A coil no dust so i am verry confused and concerned what is it and why is doing that
@MG-sg2ciАй бұрын
What ended up being your issue? I'm having the same issue with my payne furnace.
@ozarusa192Ай бұрын
@@MG-sg2ci temperature switch overheating due to too small ac coil. 17.5 inch furnace 14 inch coil. guy who installed coil did bad job cheating telling me that that size coil is fine. well after replacing coin and getting more airflow on proper size coil 17.5 runs fine and no overheating . if you have proper size ac coil check if is clean, alot dirt can collect in coil fins an restrict air flow, check presure or rollout switch.they are not expensive . but most likely is airflow restriction this high efficiency furnaces are sensitive on overheating due to airflow
@huanab2 жыл бұрын
What if there is no voltage at all? bad control board not sending power ?
@sideskraft4 жыл бұрын
My furnace fan stays on all the time. I tested the air pressure sensor and I'm only getting 25V on one terminal when the furnace is running (there's no continuity). I removed the inducer hose from the furnace tube and gently applied a vacuum with my mouth and I could hear the contacts closing, and I verified continuity with my meter. I did this several times to establish repeatability. My understanding is that the airflow passing over the tube in the furnace creates a vacuum which moves the switch diaphram and closes the contacts. I assume this closed circuit tells the furnace controller that it's OK to shut off the furnace fan. I've checked the condensate drain hoses and everything is clear. I also looked inside the metal furnace inducer tube that the switch hose fits over and saw nothing, but I did gently run a screwdriver in and out and moved it around a bit, but nothing came out, so it must be clear. Is it possible or probable that the pressure switch diaphram has aged such that it now requires excessive vacuum to sufficiently move and close the contacts? If this switch never closes will the fan run all the time?
@lifeovdeath2 жыл бұрын
Did you ever get a solution? I’m in the same situation.
@jordanblair54102 жыл бұрын
@@lifeovdeath I had the service guy come to repair it, but unfortunately I don't recall what was replaced.
@AustinTXRealEstatebyFelix Жыл бұрын
What if you read 10.2? My unit is no longer kicking the heating on and the AC works.
@turbot_ Жыл бұрын
So 0L means my safety switch needs to be replaced? I have just a wall heater eith thermopile and cant figure out whats wrong with it. I had to take the whole cover off to find the stupid safety switch. Since I have no voltage at my thermostat I'm really hoping it's just the switch and not the wiring.
@supertreat12 жыл бұрын
When I test my flame sensor the fan turns on for a bit and it registers 3 V - also my primary switch doesn't register any voltage- does that mean it's bad?
@chesstime3563 жыл бұрын
Great video thanks.
@taephillips32762 жыл бұрын
Heard steel wool was too harsh and it’s sand screen but not sure
@pablogomez75193 жыл бұрын
I'm having issues with my furnace. the blower starts, the inducer spins (I think the pressure switch is good) the ignitor does not turn on but the gas valve does click and release the gas. I did replace the ignitor. getting code 34.
@frankjames19553 жыл бұрын
i did something dumb, .. i changed my thermostat and nothing worked except the main large fan always runs no matter under what setting it is.. i put back the old thermostat but it still does the same thing... the green light on the gas valve gives me an code of- "limit circut fault"
@quymai38602 ай бұрын
I have a guy came in to swap out the controller board on my unit, warranty works, but then he induced an issue to my heat furnace. now its not turning on and throw an E04(trane system), Open thermal limit, rollout switch or RAF switch, they are safety switches that tied in a loop. All checked good but still not comming on. any idea?
@tagetes14423 жыл бұрын
My fairly old Bryant Plus 80 heater started cycling on and off every 3 minutes (that is three minutes of flame....three minutes of cold air...three minutes of flame...three minutes of cold air, so my house wasn't heating very quickly to say the least. I jumped each stop limit switch with a piece of copper wire until, lo and behold, I came to the main furnace box stop limit switch and while jumped the furnace DID NOT cycle off prematurely. I replaced the wires on that stop limit switch and the heater went back into its troublesome cycling. So this tells me that the error code was right in that the problem was a stop limit switch and my testing proved which one it was. NOW...to find out why that main furnace box stop limit switch is acting up??? (I actually replaced it with new one and the new one creates an open after three minutes as well. So Do I have this all right?
@jimbarron8688 Жыл бұрын
Actually, with the customer switch contacts closed simply use a jumper between R and W. If the ventor motor starts you know all the safeties are closed and normal. If the main blower starts you know the high limit is open. Simple.
@shellyblanchard57882 жыл бұрын
I had to recalibrate my limit switch because it was shutting down the furnace before it warmed up real good to heat. But the fan won't turn on in automatic, you have to the fan on swtich. The wire broke last winter and had to splice it. I thought maybe the had burned out , But wasn't the case. I think the switch on mechanism is not working. I took out the splice, hooked it to the wire , it still didn't come on.
@lifeovdeath2 жыл бұрын
Did you end up finding a solution? I’m about to get rider a new limit switch but I just tested it and it had voltage. My furnace turns on fine but thermostat is reading wrong temperatures, fan doesn’t turn off after lowering tempering although flame goes out.
@shellyblanchard57882 жыл бұрын
@@lifeovdeath I think my thermostat is a little off to. It could be yours may be in draft cause it to stay on longer than usual. Put the fan on automatic. Wait about 15 minutes to see if it shuts off. If is blows cold air, turn on the heat and see what tempture it comes on at. Let the the heat stay on till room warms up , check the temperature side and see it what says. If it's a digital, click downward till the burner clicks off. If it is a lever one click left or down. See how many degree it off.
@shellyblanchard57882 жыл бұрын
@@lifeovdeath one thing to if you have a wire at the side of the thermo coupling you may have a loose wire. Twist it just a bit just enough to tighten , it should stay lit when you light it. One thing to , if you have central air, check your out side compressor to see if it is running for a.c.. It may be running. You may have to pull the breaker on it if has a lever.
@lifeovdeath2 жыл бұрын
@@shellyblanchard5788 thanks. finally got it figured out 4 days later. So turns out the brand new thermostat I got was shot which got me really confused and made me run loops as to what’s wrong. Just got a different thermostat and it worked. :)
@shellyblanchard57882 жыл бұрын
@@lifeovdeath right on. Glad to help.
@dsd-downshiftdave80562 жыл бұрын
Correct me if I'm wrong, checking each side of safety to ground determines the safety is open or closed, however, it does not prove that the safety will open if there is an issue, if the safety is stuck in the closed position and will not open Then your test didn't prove the safety Is functional
@jkbrown54964 жыл бұрын
At least some boards test the pressure switch to ensure it is open before turning on the inducer fan. An auto diag youtuber, Schrodinger's Box, has a recent video using a failed pressure switch off his furnace to give a lesson multimeter scale selection for resistance. On continuity, the switch shows open, but on the 20M ohm scale it has a high resistance. Again, his board reported this fault (due to a humidifier leaking onto the furnace electronics).
@acservicetechchannel4 жыл бұрын
thanks for sharing!
@naturestrail229623 күн бұрын
I'm sitting here trying to figure out why my thermal switches have 120v? It's a 1979 Ruud electric only heat pump setup. Also been trying to figure out why there's a grey wire no label, blue wire labeled B, and no orange wire? No telling who's worked on it in the past when the thermostat was changed by the previous owners. Also, when it's set to heat pump it has electric arches jumping between a couple contacts you can hear inside the air handler. When you set it to EM heat this goes away. Anyone have a clue?
@xephael34858 ай бұрын
why test the voltage? Just put it into continuity mode and check of they're passing current.
@pablogomez75193 жыл бұрын
I'm getting reading of 24volts from all the safety devices but my ignitor (brand new) still will not turn on. I am getting gas I can hear it click and hiss. but no glow from the ignitor. please help anyone 🙏🏽
@christophbimmermann2384 жыл бұрын
It looks like you are only checking whether the limit and safety switch(es) "tripped". So if a furnace is not working, this is a good method to figure out which safety switch caused it, therefore allowing more detailed searching for the source of the problem. BUT I would not consider this testing of safety switches. For that, you would need to trip them and check whether they trip at the right temperature/condition. In my opinion, this is more a troubleshooting step, than actually testing of safety-related features. So don't believe that your safety switches work if you never actually checked if they can open ...