what happens when you design the string that respects the Voltage and I current limits of the DC inverter but the input on the PV max power on DC is greater that the limit on the specs? For example: -PV Max DC Inverter is 8kW and Solar panels installed is 10kW but is in the limit range of V and I of the MPPT
@FroniusSolar25 күн бұрын
Hi, For systems where the maximum DC power including the oversizing factor is exceeded, we cannot guarantee functionality even if the short-circuit current and open-circuit voltage limits are met. Please contact our technical support through the Solar.SOS application with your specific case. Best regards, Leo from Fronius