#c4chiller #c4chiller #chillerplant #condenser #evaporater #lubrication #chillerplantparts knowledge for HVAC team
Пікірлер: 109
@asadkarim20323 жыл бұрын
Bahut behterin knowledge
@irfanhashmi9828 Жыл бұрын
Very nice sir bahut achi videos banate hai app Apka explanation bahut jabardast krte hai bhai 😊
@c4chiller9984 Жыл бұрын
bahoot sukriya ji apka 🤗
@nesaralam17982 жыл бұрын
Sir aapki bhut si vedios Maine dekhi h bhut behtrin andaz me samjhate h ap aapki hi ek vedios dekhi thi jisme btay the ki condenser ke shell side me refrigerant aur tube side me water, evaporator/chiller ke shell side me water aur tube side me refrigerant hota h , but aapne yaha dono me same bata rahe h
@c4chiller99842 жыл бұрын
Ji ha York chiller me condenser and evaporater me same tarah hota hai ... Qki york chiller ke evaporater fluded typ evaporater hai.... Fluded typ evaporater me 👉tube me water and shell me gas hoti hai And DX typ evaporater me tube me gas and shell me water hota hai
@c4chiller99843 жыл бұрын
sorry for my mistake 🙏 hamne is vidio me evaporetor ki tube me water bataya hai ...lekin evaporater ki tube me hamari refrigrent hoti hai ..sukriya 🙏
@FOCUSAbSalaM3 жыл бұрын
Haa sir ji me bhi yahi puchne wala tha
@raaj75553 жыл бұрын
Tanku sir replace
@streamgyan233 жыл бұрын
Bhai itna galti mut kiya karo. jo galti hota hai us cien ko cut kar diya karo phir se dubara video bana kar usse sett kardiya karo. Or apka har videos mjhe aacha lagta hai ...👍
@NaseemAhmad-qv5xb2 жыл бұрын
Evaporator ke tube me water hi hota hai sir bcoz tubes are in horizontal position and water also flow horizontal so shell contains refrigerant
@taufikalam4715 Жыл бұрын
NRB GALAT BATA RAHE HAI KYO RABER BELO KO NRB BATA RAHE HAI
@redwond88did952 жыл бұрын
Bahot achha videos bnate ho bro
@c4chiller99842 жыл бұрын
Sukriya apka
@manachanelbai7837 Жыл бұрын
thank you sir ,maintenance time ka video s share karo ji
@c4chiller9984 Жыл бұрын
dost bahot si vidio hai maintenance ki ... description me link hai aap dekh sakte hai.. sukriya
@faizankhan-bo7sl3 жыл бұрын
Ek video bnaiye bhai jisme pura vapour compression cycle ka kha se kitna temp in out krta h aur refrigerant pressure kha pr kitna hota h
@vinaychauhanvinaychauhan3674 Жыл бұрын
Superb 👌👌👌👌👌sir ji...
@c4chiller9984 Жыл бұрын
thank you
@emotionalllyinspiration2 жыл бұрын
Sir compressor overhauling ka video upload kigeya
@a.samadsolkar70102 жыл бұрын
good video sir,
@c4chiller99842 жыл бұрын
Thank you ji 💐
@bantysingh73742 жыл бұрын
❤️❤️🌹🌹❤️❤️
@hanumansingh1983 жыл бұрын
Very nice viddo sir
@amjadseakh68142 жыл бұрын
As-salamu alaikum sir Bahut bahut shukriya 🙏 Allah aapko apne hibzo aamaan main rakhen🤲
@c4chiller99842 жыл бұрын
Ji walikum assalam ✨ aor apko bhi
@javeedhvactechnician77609 ай бұрын
kzbin.info5D98nA1HuR0?si=rYJxkVFzdY1xHeT3
@moonsheikh71172 жыл бұрын
Prv nd service valve dono me use hota h Evaporator and condensor dono me usw krte h
@ramakantkushwaha5458 Жыл бұрын
Very good
@asadkarim20323 жыл бұрын
Reciprocating ya centrifugal compressor me oil kaise change karte hai ustime me kon kon SA tools use karte hai Pura complete ek video banaye oil Ka temperature Kiya Hota hai
@ziaarnie36943 жыл бұрын
Make a complete video on chiller power wiring and control wiring each and everything. Thanks
@javeedhvactechnician77609 ай бұрын
kzbin.info5D98nA1HuR0?si=rYJxkVFzdY1xHeT3
@RohitSharma-ye7wn2 жыл бұрын
Sir ak video trane k chiler pr bnao
@bestaccessoriesinbudget Жыл бұрын
Bhai ek confusion hai..jab direct evaporator line se direct ahu mai cold water and hot water in or out hota hai toh chw pump kyu lgte hai
@rashidkhan10242 жыл бұрын
Very helpful vedio
@c4chiller99842 жыл бұрын
Bahoot sukriya ji apka
@javeedhvactechnician77609 ай бұрын
kzbin.info5D98nA1HuR0?si=rYJxkVFzdY1xHeT3
@Zamans22202 жыл бұрын
Nice video sir thank you. Sir ek video banaiye oil filter k bare me kaise nikal k uski cleaning hoti hai or fir kaise lagaya jata hai plz
@c4chiller99842 жыл бұрын
Ok ji jarur
@hvacshailendarshahganjup94644 ай бұрын
Good
@c4chiller99844 ай бұрын
👍
@asadkarim20323 жыл бұрын
Bahut badhia
@piyushojha52352 жыл бұрын
Sir York chiller me condenser high pressure contact open alarm kaise thik kre
@c4chiller99842 жыл бұрын
Cooling tower me water level ok rakho .. qki jab cooling tower me water level kam ho jata hai to air suck karne lagta hai jiski vajah se .. aise alarm aate hai ...
@asadkarim20323 жыл бұрын
Sir ek BAAT aur bataye agar ek chiller me tin ya char centrifugal compressor laga hua hai aur usme se ek me koi problem hogaya jisko maintenance Karna Hoga to us situation me Kiya krege chiller ko off Karke maintenance Hoga ya chiller chaltarahega aur uska maintenance Hoga ye questions mujhse client pucha hai
@c4chiller99843 жыл бұрын
Aap chiller chala sakte hai ۔۔koi problem nahi hai qki har compresser ki alag alag circuit bani hoti hai ۔۔۔bas dhayan rahe ki full shafty ke sath agar running chiller pe work kare to sukriya
@moonshiekh11003 жыл бұрын
Centrifugal compressor jo use hota h vo high ton ke plant ke liye use hota hena like 400tr se upr jab jata h tab ????? Nd dosra ye bataiye sir ki Compressor ka capacity kaise decide hota h ? As per ton yah kuch or Same waise hi mujhe puchna h pump se related uska hp capacity kaise lete h as per ton yah as per heat load calculation I know questions bhut sare ho gye but aap short me bata do Yaah is par koi video bana do sir please Compressor Pump Nd also cooling tower ka sabke capacity kaise niaklate yah pata krte h .agr koi project plan chilled water ka like 1000 tr ka Agr kise ne pucha ki is plan me Compressor cooling tower pump ka kya capacity h toh kaise me bataun ? Without looking machine i hope aap samjh gye honge question sir Please sir 🙏
@MdChand-gc1pl3 жыл бұрын
Nice but How Self identifiyed All parts of chiller
@faizankhan-bo7sl3 жыл бұрын
Evaporator ke tube me refrigerant hota h aur shell me water.mai pahle 2-3 video dekha hn usme btaya gya h ..plz confirm kijiyega
@c4chiller99843 жыл бұрын
bahoot sukriya apka ..but tube me water hota hai condenser and evaporator dono me ..
@c4chiller99843 жыл бұрын
ji bilkul u are right ....condenser ki tube me water hota hai and ..ewaporater ki tube me refrigrent hota hai ...sorry🙏
@faizankhan-bo7sl3 жыл бұрын
@@c4chiller9984 its ok bro..we all are learner and hvac field is ocean ..you are doing great work bro..keep it up
@c4chiller99843 жыл бұрын
@@faizankhan-bo7sl thanks for supporting ji 🙏
@umairbaig39123 жыл бұрын
Great sir
@ramanlal86933 жыл бұрын
Apki awaj mast hai sir
@javeedhvactechnician77609 ай бұрын
kzbin.info5D98nA1HuR0?si=rYJxkVFzdY1xHeT3
@faizankhan-bo7sl3 жыл бұрын
Bhai aapne flexible bellow ko nrv bataya ending me. i think video me 8:30 min ke bad
@chiragprajapati4853 Жыл бұрын
Sir PSI, PSIG ,PSID KYA HOTA HAI. AUR CHILLER ME YEH UNITS KAHA PER USE HOTE HAI Yeh teeno me kya difference hai??
@Shahilkidunia Жыл бұрын
Ya kon sa chiller tha air cool ki watar cool or kon sa company tha
@c4chiller9984 Жыл бұрын
Water cooled to York company hai
@martinsmartins67449 ай бұрын
good ! Could you help me with a question I have about the capacity of the York chiller? its capacity set-point
@c4chiller99849 ай бұрын
what set point like temperature or TR ?
@martinsmartins67449 ай бұрын
@@c4chiller9984 Temperature set point is at 9°C and the capacity set point is at 80%. the Chiller does not obey the set points. If I increase the capacity, after the ramp, it goes to 105% and I fell. I'm here on the other side of the world 😀 Brazil. I'm waiting for help 👍 and thank you for your attention!
@c4chiller99849 ай бұрын
Dear friend...Do you use Instagram so if you use Instagram then come in my I'd it's my I'd 👉 kgufran195 I give some suggestions by voice not
@FaheemKhan-hs8cr Жыл бұрын
Sir prv ko safety valve bhi bol skte hai ya nahi
@c4chiller9984 Жыл бұрын
PRV ( pressure relief valve) ji ha bilkul bol sakte hai 🤗 ye bhi ek shefty hi hai
@nhstatus3404 Жыл бұрын
Bhai voltas ka air cooled chiler hai satandig pressure 90 psi hai aur runing me 15 se 19 psi ho jata hai kya kare
@javeedhvactechnician77609 ай бұрын
kzbin.info5D98nA1HuR0?si=rYJxkVFzdY1xHeT3
@pradipsimpi85223 жыл бұрын
Hume injection moulding chiller plant ke bare me sikhna hai not in hvac
@Abcdvolgs10 ай бұрын
Sir kahi lagwa dijiye sir please chiller men
@jakirhusain71202 жыл бұрын
Painal ki testing bataiye sir please
@sadhucharanpanda88112 жыл бұрын
Sir please Trane chiier ke bareme video veje
@c4chiller99842 жыл бұрын
Ji abhi hamare pass to hai nahi lekin ham try karte hai agar kahi milega to ham apke liye upload kar denge sukriya
@hengineeringmind98712 жыл бұрын
Kis Bajah se Condenser Temprature badhta hai
@c4chiller99842 жыл бұрын
Jab uska pressure badhta hai
@jakirhusain71202 жыл бұрын
Painal se kaun kaun si opret hoti hai aur dB painal se kaun si opret hoti hai
@c4chiller99842 жыл бұрын
Chillers Primery pump Secondary pump Cooling tower Ahu Fcu Csu
@jakirhusain71202 жыл бұрын
To sir iska conection btaiye sir please please please please please please please drawing se hi bata dijiye sir please
@abdulsamadshaikh57593 жыл бұрын
sir g oil sum se jo line arhi wo compresor main bh ja rahi un lines ki detail
@c4chiller99843 жыл бұрын
check the my new vidio ...aaj add ho gai hai
@AbulFazal-sv7li Жыл бұрын
Sir ji , chiller Kahan rahta hai basement me ya fir kisi floor pe ya top floor pe . Pls reply me
@AbulFazal-sv7li Жыл бұрын
Ek interviewer ne mujhse pucha Maine koi bhi 3,4 floor bata diya tha wo bola nhi
@c4chiller9984 Жыл бұрын
👉agar chiller water cooled hai to .. maximum basement me lagaya jata hai .......ya phir ground floor pe ...lekin 90 % basement me lagaya jata hai ..... 👉aor agar chiller air cooled typ ka hai to ... maixmum roof top ( tarres) pe lagaya jata hai ....ya phir free of space area me ..👉.yani ki jaha pe air achi flow kare waha pe bhi laga diya jata hai
@mubashshirahmad6404 Жыл бұрын
Bhai chiller me oil pump kaha ho ta hai
@c4chiller9984 Жыл бұрын
ji bahoot jagah bahar hota hai ...ya compressor ke ander ...but ye jo york ka chiller hai ...isme oil tank ke ander hi oil pump hota hai ..👍
@SyedMoWarisSyedMowaris3 жыл бұрын
Sir ham chillar compressor Chek kaise Kare sir
@c4chiller99843 жыл бұрын
Apko kya check karna hai compressor me aap batay ؟؟
@Gopalganj.283 жыл бұрын
Sir 400 tr ka screw compressor ka chiller kitna amp lega
@Gopalganj.283 жыл бұрын
Answer plz sir
@ajwalkumarbhagyekar15242 жыл бұрын
Bhai tumne pehle bola evaporator mein shell mein paani aur tube mein gas & condenser mein tube mein paani aur shell mein gas
@c4chiller99842 жыл бұрын
Ji ha bilkul sahi .. kaha apne .. qki york chiller ka jo evaporater hai wo fluded typ ka hai ... Jisme tube side me water and shell side me gas hoti hai .... Agar yahi evaporater hamara DX typ ka hota to shall side me water hota aor tube side me gas hoti
@ajwalkumarbhagyekar15242 жыл бұрын
@@c4chiller9984 tq u so much agar apko questions puchna he to kaise contact kare ya kuch aur tarika bataav
@c4chiller99842 жыл бұрын
Ji ye mera instagram id hai 👉 kgufran195
@ajwalkumarbhagyekar15242 жыл бұрын
Okay 👍🥰
@NawazishKarim-fm8lc5 күн бұрын
HVAC me kon si oil use hoti h sir
@c4chiller99844 күн бұрын
Polyester ( POE )
@RadheRadhe-nx2ko3 жыл бұрын
Sir kitne Tr ka system laga hai
@c4chiller99843 жыл бұрын
650 ke 4 system hai
@ArvindSingh-kf6qm3 жыл бұрын
Sir parameters kitna hota h acutely chiller
@c4chiller99843 жыл бұрын
1. Oil pressure and temp. 2. Refrigerent suction pressure 3. Refrigerent discharj pressure 4.delta T 5.delta P 6. Approach temp.
@nazimhaider54952 жыл бұрын
What is work of service valve?
@c4chiller99842 жыл бұрын
Service valve wo hote hai jaha se ham gas charge karte hai gas recovery karte hai .. aor oil charge ya recover karte hai
@nazimhaider54952 жыл бұрын
@@c4chiller9984 thank you ❤️
@atif-aftab1atif3303 жыл бұрын
Sir vedio fir se bnaaye please zara slow or derail mm explain kijye please .... Please .... Please.... Bahut achhe se kiya hh but please slow nd detail mm bnaye bhale hi vedio lambi ho hme knowledge chahiye vedio apko achhi hoti hh kitni bhi lmbi ho koyi frk nhi padta
@c4chiller99843 жыл бұрын
ji jrur bana denge apke liye 🙏
@jinenderthakur81162 жыл бұрын
Why always use balancing valve n motorise valve in. Outline
@c4chiller99842 жыл бұрын
Moterize valve ek normal valve ki tarah hi kam karta hai bas isko isliye lagaya jata hai ki ham BMS se on ya off kar sake ... Aor balencing valve ko out line me ham is liye use karte hai ki water ko ham condenser me GPM ke hisab se set kar ke rok ke rakhe
@jinenderthakur81162 жыл бұрын
@@c4chiller9984 in line mai kyu nhi lgte ye dono valve