Refilling the gas in an LG dual inverter window air conditioner requires specialized knowledge and equipment, and it is recommended that the task be performed by a qualified technician.
Here is a general description of the process involved:
Turn off the power supply to the air conditioner and unplug it from the wall socket.
Remove the front cover and the filter from the air conditioner to access the inner components.
Locate the refrigerant valves on the compressor and the condenser. These valves may be covered with a cap that needs to be removed.
Connect a manifold gauge set to the refrigerant valves. This gauge set is used to measure the pressure and temperature of the refrigerant.
Connect a vacuum pump to the gauge set and evacuate the system to remove any air or moisture that may be present.
Close the valves on the gauge set and remove the vacuum pump.
Connect a refrigerant cylinder to the gauge set and open the valves to allow the refrigerant to flow into the air conditioner. The amount of refrigerant required will depend on the capacity of the air conditioner and the manufacturer's specifications.
Once the required amount of refrigerant has been added, close the valves on the gauge set and disconnect the refrigerant cylinder.
Check the pressure and temperature readings on the gauge set to ensure that the system is functioning correctly.
Reinstall the front cover and filter, plug in the air conditioner, and turn on the power supply.
It is important to note that adding too much or too little refrigerant can lead to problems with the air conditioner's performance, so it is essential to follow the manufacturer's specifications and guidelines carefully. It is also important to ensure that the technician performing the refill is properly certified and experienced in working with air conditioning systems.

Пікірлер: 30
@rundasantosh
@rundasantosh Ай бұрын
sir service k baad se fan on nahi ho raha.jabki screen me light aa rahi
@shubhammonu755
@shubhammonu755 Ай бұрын
Ye ac 2 saal bd thanda hi ni kr rha h... nd jbki wash krwayaa h hamne foam walee see
@user-bx6ei7ep9n
@user-bx6ei7ep9n 3 ай бұрын
Bina AC on kiye gas dal slti hai kya? Mere yaha technician bina AC “ON” kiye gas daal k gya hai and muje sahi nhi lga
@songsasmal8751
@songsasmal8751 Ай бұрын
Kitni purani hai a ac
@Jedi-em2qd
@Jedi-em2qd 2 ай бұрын
Lg ki cooling coil new kitne ki ati hai?
@MANOJKUMAR-it2np
@MANOJKUMAR-it2np Ай бұрын
bhai lg window ac m gas dalte he vaccum m chala jata h inverter h kya reason h
@techac
@techac Ай бұрын
Capillary band ho gayi hai uski
@PremKumar-sf1so
@PremKumar-sf1so 9 ай бұрын
Ye coil naye ac men kab tak theek chalti h? Matlb 3 saal chalne ke baad kya coil change karani chahiye?
@dhirenbhoi3642
@dhirenbhoi3642 9 ай бұрын
Split AC में दो PCB or window AC में कितना PCB लगताहे I
@techac
@techac 9 ай бұрын
Ek hi hoti hai sir
@gstanwar
@gstanwar 6 ай бұрын
Kitne ton ka compressor use krte ho pressure dalne ke liye
@techac
@techac 6 ай бұрын
1 ton ka
@naina3700
@naina3700 3 ай бұрын
LG ka dual inverter window AC ki gas Ghar per hi refill Ho Jaati Hai Ya service centre per jakar
@techac
@techac 3 ай бұрын
Ghar par hi ho jaati hai
@gstanwar
@gstanwar Жыл бұрын
Aapne compressor se hi vacuum kiya tha na
@abhishekbhardwaj4455
@abhishekbhardwaj4455 26 күн бұрын
Tabhi dikhaya nhi😂
@ShivamTiwari-dm8ft
@ShivamTiwari-dm8ft 2 ай бұрын
Bhai iska compressor apne aap cut ho raha hai ek mint bad esa kyo
@techac
@techac 2 ай бұрын
Koyi error bhi aa raha hai kiya
@techac
@techac 2 ай бұрын
Gas check ki
@JunaidKhan-ik5yw
@JunaidKhan-ik5yw Жыл бұрын
Kitne saal mein yei kharb hua jab apne theek kra tab yei kitne saal purana tha
@erahultyagi
@erahultyagi Жыл бұрын
Ye ac kitna purana hai isme to Jung bahut lag gaya h lg ac ki aysi halat hogi mene nahi socha tha
@techac
@techac Жыл бұрын
Ji
@Jedi-em2qd
@Jedi-em2qd 2 ай бұрын
@@techacbtao bhai kitna purana ac h ye
@AMITKUMAR-nf8in
@AMITKUMAR-nf8in 2 ай бұрын
@@Jedi-em2qd wo bc bata hi nhi rha hai
@SanatanSarthi1
@SanatanSarthi1 2 ай бұрын
Aapka no. Kya hai address kaha hai kaise contact hoga
@techac
@techac 2 ай бұрын
8178195024
@ShivamTiwari-dm8ft
@ShivamTiwari-dm8ft 2 ай бұрын
Plz reply
@rundasantosh
@rundasantosh Ай бұрын
sir service k baad se fan on nahi ho raha.jabki screen me light aa rahi
@techac
@techac Ай бұрын
Koyi error bhi aa raha hai kiya
@rundasantosh
@rundasantosh Ай бұрын
@@techac ch 05
CH 05 ERROR | LG DUAL INVERTER
19:56
JDL ELECTRONICS SERVICE CENTER
Рет қаралды 102 М.
Window Air Conditioner Not Cooling And The Most Common Fix
14:55
Word of Advice TV
Рет қаралды 1,8 МЛН
WORLD'S SHORTEST WOMAN
00:58
Stokes Twins
Рет қаралды 46 МЛН
Little girl's dream of a giant teddy bear is about to come true #shorts
00:32
Playing hide and seek with my dog 🐶
00:25
Zach King
Рет қаралды 34 МЛН
LG Inverter AC PCB / Circuit Fraud - LG AC PCB SCAM😡😖
13:43
Tech Buffet
Рет қаралды 210 М.
Compressor Is Running But AC Not Cooling ! Window AC Cooling Nahi Kar Raha
7:35
Запрещенный Гаджет для Авто с aliexpress 2
0:50
Тимур Сидельников
Рет қаралды 710 М.
Это Xiaomi Su7 Max 🤯 #xiaomi #su7max
1:01
Tynalieff Shorts
Рет қаралды 2 МЛН