Thanks ma'am......small correction at 12:50 it's π- Alpha
@pavanporika41353 жыл бұрын
Mam really super ur teaching is it is very useful for my current semester examss
@dilipchaudhary28504 жыл бұрын
very clear explanation mam...excellent.
@popoipuijj2343 жыл бұрын
Makasih kak, berguna sekali materinya, mama ku pasti bangga karna udah nonton
@nukuvolukeyho3211Ай бұрын
Why didn't you take π+alpha to 2π+alpha for solving average output voltage and Vrms?
@amalraj65663 жыл бұрын
Thank you mam...for the simple and clear explanations...
@praveenkumarlk8527 Жыл бұрын
very clear explanation mam
@akhilavollala13933 жыл бұрын
Mam in power expression it is π-alpha
@Isti-ye2wg3 ай бұрын
Why we have a power factor instead of resistive load?
@ravurisaiteja39882 жыл бұрын
Mem your voice so cute 🥰😁
@vineer_motiv4 жыл бұрын
Clear concept mam...
@aadhi95403 жыл бұрын
You forgot the Vm^2 in P
@rockersviewerhub47973 жыл бұрын
Nice... Mam.....🙂
@anjalikrishna60582 жыл бұрын
vm sqare ille output Rms equationil
@luvit46666 ай бұрын
Emi ardam kale jst like ma pe madam
@sanjaysatheesh49723 жыл бұрын
clarity 💯
@theju39393 жыл бұрын
oh yeah
@sanjaysatheesh49723 жыл бұрын
u too here😂
@theju39393 жыл бұрын
@@sanjaysatheesh4972 big fan ser
@srikanthkolipaka5074 жыл бұрын
We need another one also.. by using RL Load madam
@anetjose28364 жыл бұрын
kzbin.info/www/bejne/aHfaZp-fosqKi7s
@mominmoeen57342 жыл бұрын
Best explanation
@thotahemanth70123 жыл бұрын
ma'am what is the main difference between fixed 1-phase A.C voltage and variable A.C voltage
@anetjose28363 жыл бұрын
In variable AC voltage we can vary the output voltage waveform by controlling the on and off time of switches. In case of fixed AC we can't control the output voltage
@jibinmathewkurian53753 жыл бұрын
Last PF = 1/√π alle....? Just 1/π allalo...?
@loucinetriemblahjer74342 жыл бұрын
P intey equulationil Vrms edthamp Vm il ulla squlare enda idathirunnath
@kv55392 жыл бұрын
Why it is taken as 1÷π Instead of taking 1÷2π.. please reply ma'am ☹️
@anetjose28362 жыл бұрын
In case of symmetrical waves like sinusoidal voltage or current, the average value over one cycle is zero. It is because the positive half cycle is exactly equal to the negative half cycle. But the average value of positive or negative half cycle is not zero. Therefore, in case of symmetrical waves, the average value is calculated for half cycle.
@caDet076 ай бұрын
Thank you so much ma'am I was so confused about ittr😢@@anetjose2836
@caDet076 ай бұрын
Also thanks for ur question❤
@vasamsettimohithnagaadithy49842 жыл бұрын
Mam is voltage controller and voltage regulator are same
@kajaljoshi60802 жыл бұрын
What if load is 5hp motor? How to calculate power factor?
@omkarhonrao15822 жыл бұрын
Mam please check output power equation I think it is wrong.
@akhilavollala13933 жыл бұрын
Thank you so much mam ..
@srirammandala29863 жыл бұрын
Thank you madam
@letslive39873 жыл бұрын
Mam actually, when the thyristor is in forwarding bias, voltage drop doesn't happen and if it is in the reverse bias the whole voltage drops so the voltage across the thyristor graph, should be reverse I guess mam, Please can you explain?
@yadhukrishna7669 Жыл бұрын
When T is forward biased it act as closed switch thus it act as a short circuit so no voltage drop occurs but when T is reverse biased it act as an open switch so the whole applied voltage can be found on T
@dixsonjoy5394 Жыл бұрын
THANK YOU SO MUCH!!!
@aadhi95403 жыл бұрын
Why is alpha taken as 90 degrees ??
@abhinayamashetti91338 ай бұрын
u can take any angle for instance she took 90 deg
@simhadridharavath8076 Жыл бұрын
MamExplain the operation of 1-Φ AC voltage controller with RL load and derive the output voltage expression.