Single phase full wave AC voltage controller with R-load

  Рет қаралды 70,458

Anet Jose

Anet Jose

Күн бұрын

Пікірлер: 46
@kalyanbattu81
@kalyanbattu81 3 жыл бұрын
Thanks ma'am......small correction at 12:50 it's π- Alpha
@pavanporika4135
@pavanporika4135 3 жыл бұрын
Mam really super ur teaching is it is very useful for my current semester examss
@dilipchaudhary2850
@dilipchaudhary2850 4 жыл бұрын
very clear explanation mam...excellent.
@popoipuijj234
@popoipuijj234 3 жыл бұрын
Makasih kak, berguna sekali materinya, mama ku pasti bangga karna udah nonton
@nukuvolukeyho3211
@nukuvolukeyho3211 Ай бұрын
Why didn't you take π+alpha to 2π+alpha for solving average output voltage and Vrms?
@amalraj6566
@amalraj6566 3 жыл бұрын
Thank you mam...for the simple and clear explanations...
@praveenkumarlk8527
@praveenkumarlk8527 Жыл бұрын
very clear explanation mam
@akhilavollala1393
@akhilavollala1393 3 жыл бұрын
Mam in power expression it is π-alpha
@Isti-ye2wg
@Isti-ye2wg 3 ай бұрын
Why we have a power factor instead of resistive load?
@ravurisaiteja3988
@ravurisaiteja3988 2 жыл бұрын
Mem your voice so cute 🥰😁
@vineer_motiv
@vineer_motiv 4 жыл бұрын
Clear concept mam...
@aadhi9540
@aadhi9540 3 жыл бұрын
You forgot the Vm^2 in P
@rockersviewerhub4797
@rockersviewerhub4797 3 жыл бұрын
Nice... Mam.....🙂
@anjalikrishna6058
@anjalikrishna6058 2 жыл бұрын
vm sqare ille output Rms equationil
@luvit4666
@luvit4666 6 ай бұрын
Emi ardam kale jst like ma pe madam
@sanjaysatheesh4972
@sanjaysatheesh4972 3 жыл бұрын
clarity 💯
@theju3939
@theju3939 3 жыл бұрын
oh yeah
@sanjaysatheesh4972
@sanjaysatheesh4972 3 жыл бұрын
u too here😂
@theju3939
@theju3939 3 жыл бұрын
@@sanjaysatheesh4972 big fan ser
@srikanthkolipaka507
@srikanthkolipaka507 4 жыл бұрын
We need another one also.. by using RL Load madam
@anetjose2836
@anetjose2836 4 жыл бұрын
kzbin.info/www/bejne/aHfaZp-fosqKi7s
@mominmoeen5734
@mominmoeen5734 2 жыл бұрын
Best explanation
@thotahemanth7012
@thotahemanth7012 3 жыл бұрын
ma'am what is the main difference between fixed 1-phase A.C voltage and variable A.C voltage
@anetjose2836
@anetjose2836 3 жыл бұрын
In variable AC voltage we can vary the output voltage waveform by controlling the on and off time of switches. In case of fixed AC we can't control the output voltage
@jibinmathewkurian5375
@jibinmathewkurian5375 3 жыл бұрын
Last PF = 1/√π alle....? Just 1/π allalo...?
@loucinetriemblahjer7434
@loucinetriemblahjer7434 2 жыл бұрын
P intey equulationil Vrms edthamp Vm il ulla squlare enda idathirunnath
@kv5539
@kv5539 2 жыл бұрын
Why it is taken as 1÷π Instead of taking 1÷2π.. please reply ma'am ☹️
@anetjose2836
@anetjose2836 2 жыл бұрын
In case of symmetrical waves like sinusoidal voltage or current, the average value over one cycle is zero. It is because the positive half cycle is exactly equal to the negative half cycle. But the average value of positive or negative half cycle is not zero. Therefore, in case of symmetrical waves, the average value is calculated for half cycle.
@caDet07
@caDet07 6 ай бұрын
Thank you so much ma'am I was so confused about ittr😢​@@anetjose2836
@caDet07
@caDet07 6 ай бұрын
Also thanks for ur question❤
@vasamsettimohithnagaadithy4984
@vasamsettimohithnagaadithy4984 2 жыл бұрын
Mam is voltage controller and voltage regulator are same
@kajaljoshi6080
@kajaljoshi6080 2 жыл бұрын
What if load is 5hp motor? How to calculate power factor?
@omkarhonrao1582
@omkarhonrao1582 2 жыл бұрын
Mam please check output power equation I think it is wrong.
@akhilavollala1393
@akhilavollala1393 3 жыл бұрын
Thank you so much mam ..
@srirammandala2986
@srirammandala2986 3 жыл бұрын
Thank you madam
@letslive3987
@letslive3987 3 жыл бұрын
Mam actually, when the thyristor is in forwarding bias, voltage drop doesn't happen and if it is in the reverse bias the whole voltage drops so the voltage across the thyristor graph, should be reverse I guess mam, Please can you explain?
@yadhukrishna7669
@yadhukrishna7669 Жыл бұрын
When T is forward biased it act as closed switch thus it act as a short circuit so no voltage drop occurs but when T is reverse biased it act as an open switch so the whole applied voltage can be found on T
@dixsonjoy5394
@dixsonjoy5394 Жыл бұрын
THANK YOU SO MUCH!!!
@aadhi9540
@aadhi9540 3 жыл бұрын
Why is alpha taken as 90 degrees ??
@abhinayamashetti9133
@abhinayamashetti9133 8 ай бұрын
u can take any angle for instance she took 90 deg
@simhadridharavath8076
@simhadridharavath8076 Жыл бұрын
MamExplain the operation of 1-Φ AC voltage controller with RL load and derive the output voltage expression.
@naftalibett4097
@naftalibett4097 3 жыл бұрын
Thanks alot
@yathammaheswarareddy6687
@yathammaheswarareddy6687 3 жыл бұрын
Thq
@k18-y5e
@k18-y5e Жыл бұрын
no no no, thank you !
@manoharp6800
@manoharp6800 3 жыл бұрын
Thop
@simhadridharavath8076
@simhadridharavath8076 Жыл бұрын
Send me mam
Sequence control of AC voltage controller
18:30
Anet Jose
Рет қаралды 17 М.
Single phase full wave AC voltage controller with RL- load
7:20
Каха и лужа  #непосредственнокаха
00:15
За кого болели?😂
00:18
МЯТНАЯ ФАНТА
Рет қаралды 2,6 МЛН
Ice Cream or Surprise Trip Around the World?
00:31
Hungry FAM
Рет қаралды 17 МЛН
1, 2, 3, 4, 5, 6, 7, 8, 9 🙈⚽️
00:46
Celine Dept
Рет қаралды 104 МЛН
Lecture 1: Introduction to Power Electronics
43:22
MIT OpenCourseWare
Рет қаралды 817 М.
Three Phase Full Wave Controller
17:44
Devesh Jaisvval
Рет қаралды 26 М.
7 awesome applications of transistors in circuits
27:12
Electronic Wizard
Рет қаралды 131 М.
How 3 Phase Power works: why 3 phases?
14:41
The Engineering Mindset
Рет қаралды 1,6 МЛН
Single Phase Voltage Controller With Rl Load(हिन्दी )
14:38
Small Signal Amplifiers
57:53
Vocademy - Electronics Technology
Рет қаралды 403 М.
Каха и лужа  #непосредственнокаха
00:15