Bolted Connection Design Solved Examples Part 1 | Design of Steel Structures

  Рет қаралды 160,921

APSEd

APSEd

Күн бұрын

Пікірлер: 54
@manikantagodi3239
@manikantagodi3239 6 жыл бұрын
you have explained in the best possible way one can understand bro..keep doing and do a video on design of bolted connections pls
@RekhaKumari-wk7xy
@RekhaKumari-wk7xy 4 жыл бұрын
You may also like kzbin.info/www/bejne/i52XY56jgqeSiKc
@csecure6157
@csecure6157 6 жыл бұрын
amazing lecture on this topic .thanks a lot sir for such lectures
@APSEDUVERSE
@APSEDUVERSE 6 жыл бұрын
You are welcome , Anup. Hope you have checked our website where we offer a lot more : learn.apseduverse.com
@incredibleindia9844
@incredibleindia9844 6 жыл бұрын
Apsed is doing great job. I would like to have complete lecture for ese/gate . Any suggestion.
@APSEDUVERSE
@APSEDUVERSE 6 жыл бұрын
Akash Abhishek Hello Aakash, complete lectures are available from our website. Have a look at it : learn.apseduverse.com
@incredibleindia9844
@incredibleindia9844 6 жыл бұрын
@@APSEDUVERSE thanq
@akashbhorade
@akashbhorade 6 жыл бұрын
Nice sir Which software have you used for teaching ?
@Akp530
@Akp530 4 жыл бұрын
Will not we consider block shear failure of plate here?? Plz answer sir
@nabamrangkanabamrangka2946
@nabamrangkanabamrangka2946 6 жыл бұрын
What is shear plane at skunk?
@sandeepvasukuttan4153
@sandeepvasukuttan4153 4 жыл бұрын
Respected sir i would like to ask one doubt (shear capacity of bolt of one bolt x 6) in butt joint what is the reason (17:40)
@RekhaKumari-wk7xy
@RekhaKumari-wk7xy 4 жыл бұрын
You may also like kzbin.info/www/bejne/i52XY56jgqeSiKc
@UjjwalKumar-
@UjjwalKumar- 6 жыл бұрын
It is better to mention formula refered from Code Book with table Number
@vikotolcho2462
@vikotolcho2462 5 жыл бұрын
Why do were calculate the force based on pitch in some case and in others we calculate as a whole?
@tvplaystore3186
@tvplaystore3186 2 жыл бұрын
In some books the formula of strength of solid plate is (0.9×Ag×fu/safety factor) for bolted connection can you please clear this doubts why difference in formula
@seniormuchacho1868
@seniormuchacho1868 3 жыл бұрын
Please clear the writings so that everyone can understand. Thank you
@Hypocrite420
@Hypocrite420 7 жыл бұрын
Tdn is calculated per pitch length ,(not the whole length you took) 2.Vdsb and Vdpb will be multiplied by 3only instead of 6 as we consider one side of the joint.
@2TradesADayofficial
@2TradesADayofficial 6 жыл бұрын
you must calculate for 6 only not 3 bolts . each plate is involved in all 6 bolts ,If you were to find no of bolts required on the basis of Bolt value and total load . you would get 6 only.
@dineshahongshangbam7144
@dineshahongshangbam7144 6 жыл бұрын
Sir i think in strength of plate only one bolt should consider instead of 3 as critical one should be consider
@Pradeepkumar-by1dt
@Pradeepkumar-by1dt 7 жыл бұрын
at 9:30 why did you used the ultimate strength of plate instead of the ultimate strength of bolt even though you were calculating the bearing strength of "bolt".
@v_naveen_9676
@v_naveen_9676 7 жыл бұрын
in formula that is fu only.. check IS800;2007 - class 10.3.4
@Pradeepkumar-by1dt
@Pradeepkumar-by1dt 7 жыл бұрын
thank you bhai..
@travelvlogger8509
@travelvlogger8509 6 жыл бұрын
In calculating bearing stress we r actually taking the projected area of the bolt on the plate, so we need to take the ultimate tense stress of plate not the bolt
@PankajSharma-lh5yk
@PankajSharma-lh5yk 6 жыл бұрын
Pradeep kumar I too have the same doubt
@ashutoshmahapatra4334
@ashutoshmahapatra4334 4 жыл бұрын
During the calculation of strength of bolt why the lesser value is taken between the shear strength and bear strength.....
@A.R.S.0909
@A.R.S.0909 7 жыл бұрын
i think u missing 0.9 in strength of solid plate
@2TradesADayofficial
@2TradesADayofficial 6 жыл бұрын
There is no need for .9 , see clause-6.2 of IS-456 . Here strength is due to yielding of gross section
@Sam-lv7xr
@Sam-lv7xr 6 жыл бұрын
Whenever section failure is yielding I.e limit state of serviceability no need to multiply by 0.9
@kabirdas8801
@kabirdas8801 4 жыл бұрын
@Vishal Gahane dono ka value sam hota hai
@kabirdas8801
@kabirdas8801 4 жыл бұрын
@Vishal Gahane but edge distance is denoted by 'e' and end distance is denoted by e' ☺ a/c to is456
@RekhaKumari-wk7xy
@RekhaKumari-wk7xy 4 жыл бұрын
You may also like kzbin.info/www/bejne/i52XY56jgqeSiKc
@hemantdhaked8530
@hemantdhaked8530 7 жыл бұрын
Sir, i think you forget to post part-2 of this Lecture 10. i think solution of second example is incomplete.
@APSEDUVERSE
@APSEDUVERSE 7 жыл бұрын
Thanks for noticing..I forgot to add it in playlist. Now it is there. You can see the following link also: kzbin.info/www/bejne/q3bTg4ucotFsn68
@aryanraj3760
@aryanraj3760 4 жыл бұрын
@APSED please provide the lecture of strength of plate in block shear
@APSEDUVERSE
@APSEDUVERSE 4 жыл бұрын
Hey Aryan, thanks for showing interest in our lectures. For a complete set of lectures on all lectures visit our website learn.apsed.in; We have exclusive courses for Civil Engineering covering full syllabus with doubt support.
@orfeaspapaioannou2755
@orfeaspapaioannou2755 4 жыл бұрын
is it ec3?
@agajokhio9006
@agajokhio9006 6 жыл бұрын
why we are using least value of kb at bolt connection problem
@ashutoshmahapatra4334
@ashutoshmahapatra4334 4 жыл бұрын
Plz describe
@anishlamsal6022
@anishlamsal6022 5 жыл бұрын
why did you add As also ?? In the book, they only take An
@Premanandjima_haraj
@Premanandjima_haraj 4 жыл бұрын
Formula of end distance is 1.5d°
@bijobabu9992
@bijobabu9992 5 жыл бұрын
Hw do find 30,60????
@papipopo1015
@papipopo1015 5 жыл бұрын
please clear the writings on your presentation, i can't read them clearly, thanks in advance
@RekhaKumari-wk7xy
@RekhaKumari-wk7xy 4 жыл бұрын
You may also like kzbin.info/www/bejne/i52XY56jgqeSiKc
@NIOSTMASOLUTION10TH12TH
@NIOSTMASOLUTION10TH12TH 5 жыл бұрын
Bro d is 180 n
@ShareInfinity-l7m
@ShareInfinity-l7m 6 жыл бұрын
Efficiency???????
@RekhaKumari-wk7xy
@RekhaKumari-wk7xy 4 жыл бұрын
You may also like kzbin.info/www/bejne/i52XY56jgqeSiKc
@juhisingh7662
@juhisingh7662 Жыл бұрын
V p singh.... Nit kkr😂😂😂
@pankajjoshi5752
@pankajjoshi5752 5 жыл бұрын
Fu kha se aaya 400
@Arun_singh01
@Arun_singh01 6 жыл бұрын
bhai jb tune video bnayi hi h to writting to sahi se likh leta....bhai teri writting ki wajh se is video ki bhut ka m ho gyi h
@ashwinkhairnar1868
@ashwinkhairnar1868 6 жыл бұрын
Explanation is nice, but hand writing is not easy to read. Please improve hand writing.
@APSEDUVERSE
@APSEDUVERSE 6 жыл бұрын
Digital pen makes it a bit like that. Nevertheless we are trying to improve.
@vitrovogan9635
@vitrovogan9635 5 жыл бұрын
@@APSEDUVERSE it is good
Quando eu quero Sushi (sem desperdiçar) 🍣
00:26
Los Wagners
Рет қаралды 15 МЛН
BOLT TENSION and Tension at Non-Permanent Joints in Just Over 10 MINUTES!
11:29
The Genius Way Computers Multiply Big Numbers
22:04
PurpleMind
Рет қаралды 193 М.
The Incredible Strength of Bolted Joints
17:58
The Efficient Engineer
Рет қаралды 3,3 МЛН
Problem 1 Design of Bolted Connections | Design of Steel Structures
24:12
How to STUDY so FAST it feels like CHEATING
8:03
The Angry Explainer
Рет қаралды 2,4 МЛН
SM2E1 SIMPLE BOLTED CONNECTIONS - CONCEPTS
22:25
siR EdGAr CRuz
Рет қаралды 4,6 М.
Design of tensile strength of plate problem
23:31
CIVIL ENGINEERING COURSE Theory & Practical
Рет қаралды 10 М.