Autoclave Validation, Minimum and Maximum Load,

  Рет қаралды 5,797

PHARMAVEN

PHARMAVEN

Күн бұрын

Autoclave Validation Minimum and Maximum Load, @PHARMAVEN #aseptic #sterile #validation #pharma #autoclave
What is Minimum Load and Maximum Load in Autoclave? Why Required? @PHARMAVEN #aseptic #sterile
#minimum
#maximum
#dhavalkumar
#surti
#aseptic
#tiktok
#pharmaknowlege
#pharma
#gmp
#pointblank
#bacterial
#bacteria
Steam Quality in Steam Sterilization
What is Non Condensable Gases?
What is Superheated Steam?
What is Dryness Value?
Terminal Sterilization of Products #sterilization #autoclave #aseptic ‎@PHARMAVEN #usfda #quality
risk assessment
aseptic area in microbiology
aseptic technique
data integrity
data integrity pharmaceutical
depyrogenation tunnel working..
gmp
risk assessment procedures
root cause analysis examples
what is sop and how to write it
annex 1
audit para reply
Dashboa..
Content
Analytics
Comme
PHARMAVEN
aseptic area in pharmaceutical..
aseptic filling process
dhaval surti
funny lungi dance
gemba
media fill failure investigation
pharma
Sop
sop in pharma industry
audit
gmp audit
investigation report writing
Why Air Removal not required in Terminal Sterilization?
How To Develop Terminal Sterilization Cycle?
Why Vacuum not required in Terminal Sterilization?
What is D Value?
What is F0 Value based Sterilization Cycle?
Why Air Removal is Required in Autoclave?
How to calculate F0 Value?
What is Overkill Cycle in Steam Sterilization?
#superheated
#steam
#dryness
#gases
#sterilization
#autoclave
#aseptic
#usfda
#steam
#bacteria
#bacterial
#filter
Why Air Removal is Required in Autoclave?
How to calculate F0 Value?
What is Overkill Cycle in Steam Sterilization?
#sterilization
#autoclave
#aseptic
#usfda
#steam
#bacteria
#bacterial
#filter
#pharmaknowlege
#sterility
#qualityassurance
#quality
#sterile
#gmp
What Happened when an Engineered virus escapes lab?
@PHARMAVEN
#pharmaknowlege
#sterility v
#qualityassurance
#quality
#sterile
#gmp
@PHARMAVEN

Пікірлер: 31
@maheshpatel2206
@maheshpatel2206 18 күн бұрын
Jaberjust
@ravishankarmodi7492
@ravishankarmodi7492 Жыл бұрын
Sir the way u explain is very fantastic.... Thank u sir
@shrikrishnakarnataki4876
@shrikrishnakarnataki4876 2 ай бұрын
Very nice! Please also state the importance of the number of pulsating vacuum applications being included in the validation protocol.
@kichootv
@kichootv Жыл бұрын
What is Minimum Load and Maximum Load in Autoclave? Why Required? @PHARMAVEN #aseptic #sterile
@sumitkumarsharma3914
@sumitkumarsharma3914 Жыл бұрын
Thank u so much sir Very helpfull
@shawezmalik6823
@shawezmalik6823 Жыл бұрын
Nice information sir thank you sir
@PHARMAVEN
@PHARMAVEN 8 ай бұрын
What is Fix Load in Autoclave? ​⁠ #autoclave #sterilization #validation #ich #dhaval
@PharmGrow
@PharmGrow Жыл бұрын
Can we consider empty chamber load as minimum load ? I was searching for this question and you answered perfectly. 06:30 Keep posting thanks.
@PHARMAVEN
@PHARMAVEN Жыл бұрын
Many Thanks For Your Appreciation, Please also share to your Friends and Groups and Juniors to Spread Knowledge
@maheshgeergiri5606
@maheshgeergiri5606 Жыл бұрын
Great knowledge sir.
@nirmalsartana4061
@nirmalsartana4061 Жыл бұрын
Nice information sir
@pravinsingh8170
@pravinsingh8170 Жыл бұрын
Ap validation sterilization autocalve paer video banaiye
@bhupendrashukla1972
@bhupendrashukla1972 Жыл бұрын
Nice explanation...
@pravinsingh8170
@pravinsingh8170 Жыл бұрын
Validation me kitne cycle calate hai kitna uspe sir pa video bnaaye
@pravinsingh8170
@pravinsingh8170 Жыл бұрын
Ye hospital se relatevie video banaye hai ya pharam comapny mu use hone Wale autocalve validation 37 ye kya hai kis guidelines me hai
@sumitkumarsharma3914
@sumitkumarsharma3914 Жыл бұрын
Sir plz make a video on Hot VLT and Cold VLT I want to difference between in both in detail
@saurabhmehta9173
@saurabhmehta9173 Жыл бұрын
Thanks Dhaval bhai for such an informative video Can you suggest which pharmacopeia to refer for defining validation tempelate in a regulated environment?
@PHARMAVEN
@PHARMAVEN Жыл бұрын
Any Pharmacopeia will not have templates for validation. Regulatory guidance and 21 CFR Rules provides rules and guidance to follow. Documentation templates we have to make of our own. There are various sites which provide templates, you can choose suitable one and can also modify to suite your requirements
@pushkarrawat5272
@pushkarrawat5272 Жыл бұрын
If we need sterilized other material (eg.forceps) which is part of maximum load but not identified as a worst case material, than we put both material (required item + worst material identify)during run of minimum load or only put required material(forceps) and start minimum run.
@PHARMAVEN
@PHARMAVEN Жыл бұрын
In such case, you need to put all load items validated as minimum load and the item (forceps). You must put what was validated as minimum load for every such case
@pushkarrawat5272
@pushkarrawat5272 Жыл бұрын
@@PHARMAVEN thanku sir
@PHARMAVEN
@PHARMAVEN Жыл бұрын
Welcome Pushkar
@VinodKumar-hv3hg
@VinodKumar-hv3hg Жыл бұрын
If you validate the max load. It means there is no panitration problem. How can panitration problen in comes in minimum load.
@PHARMAVEN
@PHARMAVEN Жыл бұрын
Steam follows easy path. In Maximum Load, There is no escape for steam due to load and forced penetrate load. In minimum load, steam has lot of empty space to escape hence can be a problem for penetration
@VinodKumar-hv3hg
@VinodKumar-hv3hg Жыл бұрын
@@PHARMAVEN I think Mini load have more surface area for steam working in comparison of maximum load more side of material has been covered by each other. More surface area. more active side, more action.
@redride6517
@redride6517 11 ай бұрын
But sir when max load successfully completed then why MIN load require while already done MAX load
@PHARMAVEN
@PHARMAVEN 11 ай бұрын
In my video. Refer section at minute 6:30
@rushalinaik9813
@rushalinaik9813 Жыл бұрын
My question is Can we take only maximum load during annual validation as a worst case scenario. Because we have validate minimum load during PQ for thrice and continued the practice for annual validation till date. so on the basis of substantial data of minimum load we can take only maximum loads as a worst case scenario.however our autoclave is about 12years old so we have enough data for minimum load pattern which r found satisfactory. Kindly send your feedback.
@PHARMAVEN
@PHARMAVEN Жыл бұрын
Based on risk assessment and data analysis, you can eliminate some of minimum loads I recommend that the load Pattern for product which are filed to agency should be done, other loads such as garments, sanitization load etc can be eliminated
@rushalinaik9813
@rushalinaik9813 Жыл бұрын
Thank u sir
@thyagarajanparthasarathy9442
@thyagarajanparthasarathy9442 5 ай бұрын
Try to explain in English sir.
小蚂蚁会选到什么呢!#火影忍者 #佐助 #家庭
00:47
火影忍者一家
Рет қаралды 114 МЛН
小路飞嫁祸姐姐搞破坏 #路飞#海贼王
00:45
路飞与唐舞桐
Рет қаралды 29 МЛН
Aseptic processing
5:44
BrinoxProcessSystems
Рет қаралды 103 М.