Application SWCs can receive signals with Idt data types? Or they only can receive Adt data types Also, the Actuator Sensor SWCs receives only signals with Idt data types?
@BTCEmbedded6 ай бұрын
Basically Application Data Types only exist in an early phase of architecture specification, because implementation specific information (e.g. basetypes) is not part of the Adt. So on the implementation level (C-Code) only Idts exist and only the Idt names will be seen in the code. This is the case for any kind of software incl. application SWCs and Actuator Sensor SWCs.
@carlosdiaz4535 Жыл бұрын
Thanks for this explanation, I was recently searching for this particular topic! Is it possible for you to talk about different VariableAccess roles (dataSendPoints, etc), and some usages? I've haven't had the need of using anything different to dataWriteAccess and dataReadAccess.
@BTCEmbedded Жыл бұрын
Hi Carlos, thanks for the nice feedback. We'll put this topic on our list for future videos.
@sai2211 Жыл бұрын
The content is good, could you provide lengthy videos 🙂👍.
@BTCEmbedded Жыл бұрын
@sai2211 Thanks for the nice feedback. You can find more videos incl. all our recorded webinars at www.btc-embedded.com/videos/.