by far in youtube this channel is the best for tutorials
@jbjbjbjbjbjb67576 жыл бұрын
I was struggling trying to figure out how to do this in Revit. This was very helpful! Thank you! 🙏🏻
@louisafoster16404 жыл бұрын
Thank you Balkan. You're amazing!
@auto-fav8969 Жыл бұрын
really appreciate this video
@Rc-yp9vh2 жыл бұрын
Fantastic tips!! Thank you:)
@myscape88432 жыл бұрын
i cant help but say thank you.
@gsaarchitecturalmechanical58726 жыл бұрын
Thank you very much teacher. Very awesome, I always wanted to master the art of doing foundation call out, I watched a tutorial from another channel and they didn’t do it the way how you did yours by adding the skirt around the building for water drainage, they show the stucco on the exterior wall and created a drip edge, I prefer to do it the way how you d it because it seems more effective. Have a blessed day
@vijaym39733 жыл бұрын
Aa
@engineeringmind34 жыл бұрын
Very detailed ❤️
@konanblejustin8554 жыл бұрын
Great video
@ReelAESklarzykVO3 жыл бұрын
go to 11:50 to get past the material selection of walls and foundations.. aka get to the good stuff
@yuriykabanets76653 жыл бұрын
Thank You!
@lyleanthonytallo73564 жыл бұрын
what happen line cut in time 14:56 min
@jesus189985 жыл бұрын
Amazing man
@gabrielmendez92966 жыл бұрын
Gracias realmente buenos tutoriales
@gal2ra2y4 жыл бұрын
Concrete at perimeter of the bldg is called protection strip. Yw.
@Lado936 жыл бұрын
its nice detail but i have a thermal bridge in it. you need put therm insolation all over that little wall that is on bottom
@olik1366 жыл бұрын
not if the insolation in the floor is about 10cm- it is in theory still a thermal bridge but it is considered to have no impact - I would still but insolation on there especially because it is not underground- also the dimension of the bottom plate seems much to small
@Lado936 жыл бұрын
man floor on terrain need list 15 if not 20 cm of insolation + hydroisolation and especially you need isolate the foundations like is it here : imaterialy.dumabyt.cz/obrazek/586f9ab3cb3b3/hi-nepodsklep-rd-05-06-1.jpg
@olik1366 жыл бұрын
Oh I thought you meant something like this www.bauexpertenforum.de/attachments/frostschuerze-jpg.50130/ with "all over" the wall- I was just talking of the inner side of the foundation that you don't- have to insolate (like in your picture) although it is actually a thermal bridge
@wipidipipaku3 жыл бұрын
So, if we change the patterns of the materials to be shown like that in the callout, then if desire not to see it in floor plans, what should we do?
@TTillahFK4 жыл бұрын
So that protection strip must be for use on very slope sites otherwise do some PE80 porforated pipes as drainage instead..
@fridoniz.a3986 Жыл бұрын
bagaimana dengan pondasi setempat (isolated fondation) yg tidak terkena potongan, tapi iningi dimunculkan pada gambar? terimakasih
@hearthrob3006 жыл бұрын
Instead of that ground level floor to channel water away from the foundation footing, you can use weeping tile
@markkibui80354 жыл бұрын
Hi, is it possible to automate foundation details for different projects with similar details instead of doing the task every time?
@zx6r986 жыл бұрын
Thanks mate
@monica28136 жыл бұрын
really appreciate this video, but I just found out that the line in the section can not show its thickness, all is the same. Does anyone know how to settle this problem? thank you.
@araizazkhan96055 жыл бұрын
Thank you
@QcHoangThong6 жыл бұрын
thanks u so much from Viet nam
@mavic_afg4 жыл бұрын
What to do when the floor and wall intersect
@mavic_afg4 жыл бұрын
Intersect
@abdober33024 жыл бұрын
You have to duplicate TYPE befor modification
@aviajmeri79916 жыл бұрын
Takes more time to make detail in revit
@MercedesBenzS600LAMG6 жыл бұрын
That's true, but once it's done in revit, modifying it is easier and takes less time , and in addition to that it will be a real 3D model
@daliagregorova15522 жыл бұрын
I am getting so fed up with this software. How can there by a system function to automatically generate wall foundations, but then you have to manually create a gravel layer under them?!? That's so utterly ridiculous. I am seriously considering to bother myself with learning a new SW so I don't have to deal with this mastodont that is getting extinct anymore ughhhhh
@richardidika51897 ай бұрын
Which other software doesn't do it manually?
@SS-xx2qp4 жыл бұрын
very fast
@santinosantino31642 жыл бұрын
even though the commands are clear....the application is ineffective..........reason being. this guy is not an architect.
@samirsaddedis7115 жыл бұрын
you need to take your time when you are drawing you are too fast and we can't follow you, remember its a teaching session, not a competition.
@tonyk43215 жыл бұрын
What fucking hatches you using over there in Rumunia? Horrible.
@ingabbateantonio3 жыл бұрын
several technical mistakes, you are not an engineer, and clearly do not know much about foundations, several mistakes, and you also explained why those mistakes, which is pure madness....stick to your role as an architect, whe doin engineering stuff please state that you do know what and why you are doing but you know how it looks, and that's all. I am fan of you bro, but know your limits. peace